★ Independent, reader-supported & ad-free · Watching the watchers in all 50 states ★ Support Us
The Docket · Government Meeting · DKT-2026-000135

On the agenda: Sanger meeting — FLOCK CAMERA (Feb 19)

Past  ⚠ Agenda Watch  Sanger, California · Thursday, February 19, 2026 — 7 months ago

About this record

The published agenda for this February 19 meeting contains: "FLOCK CAMERA". The meeting has passed; the record and its outcome live here permanently.

WhenThursday, February 19, 2026
Check the agenda document for the meeting time.
WhereSanger, California
Money$500 was at stake
On the record“FLOCK CAMERA”

The agenda, word for word

Government public record — the full text of the published document, archived July 20, 2026. Gold highlighting of key terms is ours, not the original’s. Read the original document ↗

179 pages · scroll to read
Page 1 of 179

AVAILABLE FOR REVIEW 72 HOURS
PRIOR TO THE CITY COUNCIL MEETING
AT THE SANGER LIBRARY, CITY CLERK’S OFFICE AND
THE SANGER CITY HALL
LOBBY.

AGENDA
SANGER CITY COUNCIL REGULAR MEETING
THURSDAY, FEBRUARY 19, 2026
6:00 PM
COUNCIL CHAMBER
TH
1700 7 Street, Sanger, California 93657
Levine Act Disclosure. Pursuant to the Levine Act (Govt Code Section 84308), any party to a permit,
license, contract, or other entitlement before the City Council is required to disclose on the record any
contribution, including aggregated contributions, of more than $500 made by the party or the party’s
agents within the preceding 12 months to any City official. Participants and agents are requested to make
this disclosure as well.
The disclosure should be made when the agenda item is called and must include the name of the party,
participant, or agent, and any other person making the contribution, the name of the recipient, the
amount of the contribution, and the date the contribution was made. Council Members are also required
to make such disclosures and recuse themselves.
Conflicts of Interest. Council Members are required to disclose conflicts of interests and recuse themselves.
Prior to action by the Council on any item on this agenda, the public may comment on that item.

A.

CALL TO ORDER

B.

OPENING CEREMONIES
Invocation
Flag Salute
Roll Call

C.

AGENDA APPROVAL, ADDITIONS AND/OR DELETIONS

D.

PUBLIC FORUM

(This portion of the meeting is reserved for members of the public who wish to address the Council on
any matter not listed on the agenda and within the subject matter jurisdiction of the City Council. Each
speaker is limited to three minutes. Speakers shall address all comments to the Mayor and the Council
as a body and not to any particular Council Member or member of the staff. Speakers are asked, but
not required, to state their name and address. The Council is prohibited by law from taking action on
items not on the agenda.)

Page 1

Page 2 of 179

E.

City Council Agenda
February 19, 2026
Page 2

CONSENT CALENDAR

(Matters listed under the consent calendar are considered routine and will be enacted by one
motion and one vote. There will be no separate discussion of these items. If discussion is desired,
a member of the audience or a Council Member may request an item be removed from the
Consent Calendar and it will be considered separately.)

1.

SUBJECT:
Minutes of Regular Council Meeting and Special Meeting held on
February 5, 2026.
RECOMMENDATION:
That the City Council approve.

2.

SUBJECT:
Payroll for the month of January, including Direct Deposit Nos.
68711 through 69098, Payroll Check Nos. 60744 through 60782, and Benefit
Check Nos. 2182 through 2189.
RECOMMENDATION: That the City Council approve.

3.

SUBJECT:
Warrants, including Check Nos. 96331 through 96534, for the
month of January 2026.
RECOMMENDATION: Informational Item.

4.

SUBJECT:
Fire Department Monthly Report-January 2026
RECOMMENDATION: Informational Item.

5.

SUBJECT:
Police Department Monthly Report-January 2026
RECOMMENDATION: Informational Item.

6.

SUBJECT:
Receipt of Update on Emergency Repairs at Wastewater Treatment
Plant Pursuant to Resolution No. 2025-95 and Request to Continue Declaration of
Emergency
RECOMMENDATION: That the City Council adopt Resolution 2026-11 continuing
the Declaration of Emergency and receive the report from City Manager Regarding
Emergency repairs at Wastewater Treatment Plant per Resolution No. 2026-04.

7.

SUBJECT:
Authorization for Out of State Travel – Water Operations Manager
RECOMMENDATION: That the City Council authorize out of state travel for Water
Operations Manager to attend the California Rural Water Association (CRWA)
Education and Exhibitor Expo in South Lake Tahoe, Nevada from April 27 – 30, 2026.

8.

SUBJECT:
Water Valve Assessment Project
RECOMMENDATION: That the City Council authorize the City Manager to
enter into an agreement with Specialized Utility Services Program (SUSP) for
the Water Valve Assessment Project in an amount not to exceed $95,000.

9.

SUBJECT:
Out of State Travel Request-FIRE
RECOMMENDATION: That the City Council approve the out of state travel and
training for the Fire Department Fire Chief Paramedic Liaison Office and Fire
Inspector to attend the ESO Training Academy and Wave Conference from April
6-10, 2026, in Austin Texas.
Page 2

Page 3 of 179

F.

City Council Agenda
February 19, 2026
Page 3

DEPARTMENT REPORTS
1.

G.

SUBJECT:
Review and Acceptance of the City of Sanger – Industrial
Pretreatment Program Local Limits Evaluation Report
RECOMMENDATION: That the City Council accept the City of Sanger - Industrial
Pretreatment Program Local Limits Evaluation Report conducted by AM Consulting
Engineers and authorize the Public Works Director or designee to submit the report
and propose updated local limits to the Regional Water Quality Control Board for
review and approval.

PUBLIC HEARING
1.

SUBJECT:
Initiation of Annexation of Real Property for Regional Storm Drain
Facility – Property located on the South Side of North Avenue Between Indianola
and Bethel Avenues (APN 332-080-40).
RECOMMENDATION: That the City Council:
a. Staff Recommends that City Council adopt Resolution 2026-12 to request
the Fresno Local Agency Formation Commission (Fresno LAFCO) to take
proceedings for the Annexation of a planned Regional Storm Water Drain
Facility and Associated Finding of Exemption Under Public Resources Code
Section 21083.3 and California Environmental Quality Act (CEQA) Guidelines
Section 15183.
b. Waive the full reading and introduce, by title only, Ordinance No. 2026-02
an ordinance of the City Council of the City of Sanger approving Zoning
Ordinance Map Amendment No 2026-01 for pre-annexation zoning from
Fresno County’s AE-20 (Exclusive Agriculture) to the City’s RSC (Recreation,
Schools, and Conservation) zone district for approximately 11.42 acres
located on the south side of North Avenue between Indianola and Bethel
Avenues (APN 332-080-40)

H.

CITY MANAGER/STAFF COMMUNICATION

I.

REPORTS AND MATTERS INITIATED BY CITY COUNCIL MEMBERS

(This portion of the meeting is reserved for the Mayor and Council Members (i) to make brief
reports on boards, committees, and other public agencies, and at public events, (ii) to initiate new
matters and to request updates, and to initiate new agenda items. Under this section, the Council
may take action only on any items specifically agendized and which meet other requirements for
action.)

Page 3

Page 4 of 179

City Council Agenda
February 19, 2026
Page 4

J.

ADJOURNMENT
I certify under the penalty of perjury, under the laws of the State of California that the foregoing
agenda was posted in accordance with the applicable legal requirements. Dated this 13th Day of
February 2026.

Lina Martinez, City Clerk

ADA COMPLIANCE AND REASONABLE ACCOMMODATIONS POLICY. The Council has adopted a
Reasonable Accommodation Policy which is available on the City website at www.ci.sanger.ca.us or
upon request by emailing the City Clerk at [email protected]. The Policy provides a procedure
for receiving and resolving requests for accommodation to participate in this meeting. If you need
assistance in order to attend this Council meeting or require auxiliary aids or services, e.g., hearing
aids or signing services to make a presentation to the Council, please email the City Clerk or call by
phone at (559) 876-6300 extension 1350 so such aids or services can be arranged. Accommodations
should be requested as early as possible as additional time may be required in order to provide the
requested accommodation.
TRANSLATION SERVICES. Translation services in Spanish will be provided upon request.
NOTICE OF AVAILABILITY OF AGENDA DOCUMENTS. Writings related to the agenda are available at Sanger
City Hall, 1700 7th Street, Sanger, CA 93657 and are posted online at www.ci.sanger.ca.us.
Writings
provided to a majority of the City Council within 72 hours of the meeting regarding any item on this agenda
will be made available for public inspection at the City Clerk’s Office located at Sanger City Hall, 1700 7th
Street, Sanger, CA 93567 and will be posted online at www.ci.sanger.ca.us.

Page 4

Page 5 of 179

E-1
Minutes for Special Council Meeting

THURSDAY, FEBRUARY 5, 2026
5:00 PM
COUNCIL CHAMBER
1700 7TH Street, Sanger, California 93657
A.

CALL TO ORDER

The Special Meeting of the City Council was called to order at 5:11 PM.
B.

ROLL CALL

Present: Mayor Frank Gonzalez, Mayor Pro Tem Daniel Martinez, Council Member
Esmeralda Hurtado, Council Member Michael Montelongo
Absent: Council Member Dolores Melendez
ATTENDANCE: Council Member Melendez arrived at 5:37 p.m.
C.

AGENDA APPROVAL

The Council by motion of Council Member Montelongo approved the agenda as posted. The
motion was seconded by Council Member Hurtado, and approved by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO
NONE
NONE
MELENDEZ

D.

PUBLIC FORUM -

E.

CLOSED SESSION

NONE

The Council adjourned to Closed Session at 5:12 pm.
1. Pursuant to Government Code Section 54957.6
CONFERENCE WITH LABOR NEGOTIATORS
Agency designated representatives: Shelline Bennett, Lead Negotiator, Amanda
Champion, HR Manager. Employee Organizations: Sanger General Employees
Organization, Sanger Middle Management Organization,
Unrepresented/Confidential Employees and Executive Employees
Page 5

Page 6 of 179

City Council Special Meeting Minutes
February 5, 2026
Page 2

2. Conference with Legal Counsel – Pending Litigation Pursuant to Government Code
Section 54956.9(d)(1).
Case: Gardeazabal v. City of Sanger, Fresno County Superior Court Case No.
25CECG04536 (Bane Act, battery, and torts)
3. Conference with Legal Counsel – Anticipated Litigation
Deciding whether to initiate litigation pursuant to Government Code Section
54956.9(d)(4)
Number of Cases: One case

The Council reconvened the Special Meeting at 6:17 pm.
F.

CITY ATTORNEY REPORT FROM CLOSED SESSION

No reportable Action
G.

ADJOURNMENT

Being no further business, the Council adjourned their Special Meeting at 6:17 pm.
ATTEST:
____

Amanda Champion, Deputy City Clerk

Page 6

Page 7 of 179

Minutes for Regular Council Meeting

THURSDAY, FEBRUARY 5, 2026
6:00 PM
COUNCIL CHAMBER
TH
1700 7 Street, Sanger, California 93657
A.

CALL TO ORDER

The City Council called their meeting to order at 6:17 pm.
B.

OPENING CEREMONIES

The invocation was offered by Pastor Paul Canaday
The flag salute was led by Mayor Frank Gonzalez.
Roll Call:
Present:

Mayor Frank Gonzalez, Council Member Esmeralda Hurtado, Council Member Michael
Montelongo, Council Member Dolores Melendez

Absent:

None

C.

AGENDA APPROVAL, ADDITIONS AND/OR DELETIONS

The Council by motion of Council Member Michael Montelongo approved the agenda with the
removal of Item G-14, subtopic (c), and Item H-2, to be held at a later date. The motion was
seconded by Council Member Dolores Melendez and approved by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO, MELENDEZ
NONE
NONE
NONE

D.

CEREMONIAL MATTERS
NONE

E.

PRESENTATIONS• Sanger Fence-Austin Renteria
• Virginia Harmon-Investment Report for the quarter ended September 30,
2025
Page 7

Page 8 of 179

City Council Meeting Minutes
February 5, 2026
Page 2

F.

PUBLIC FORUM
Thirteen members of the public spoke

G.

CONSENT CALENDAR

By motion of Council Member Montelongo, the Council approved all Consent Calendar Items with
the exceptions of items G-3, G-6, G-8 & G-14. The motion was seconded by Council Member
Melendez and passed by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO, MELENDEZ
NONE
NONE
NONE
1.

SUBJECT:
APPROVED-Minutes of Regular Council Meeting and Special
Meeting held on January 15, 2026.

2.

SUBJECT:
APPROVED-Receipt of Update on Emergency Repairs at Wastewater
Treatment Plant Pursuant to Resolution No. 2025-95 and Request to Continue
Declaration of Emergency.

4.

SUBJECT:

5.

SUBJECT:
APPROVED-Memorandum of Understanding between the City of
Sanger and Sanger General Employees Organization.

7.

SUBJECT:

9.

SUBJECT:
APPROVED-Resolution Authorizing the City Manager to Execute
Master Encroachment Agreements with Public Utility Providers.

10.

SUBJECT:
APPROVED-Accept Funds from the San Joaquin Valley Air Pollution
Control District Zero-Emission Landscaping Equipment Voucher Program.

11.

SUBJECT:

12.

SUBJECT:
APPROVED-Water Main Easement Acceptance & Basin
Covenant Approval Site Plan Review No. 25-08-Tractor Supply Center.

13.

SUBJECT:
APPROVED-Tract 6531 – Serenade II Subdivision Zoning
Ordinance Amendment No. 2025-02 (ZOA 2025-02).

APPROVED-Transportation Development Act (TDA) Claim.

APPROVED-Declaration of City Vehicles as Surplus Property.

APPROVED-Sodium Hypochlorite Supply for City of Sanger.

Page 8

Page 9 of 179

City Council Meeting Minutes
February 5, 2026
Page 3

Item G-3
3.

Pulled by Resident Rocha
SUBJECT:

APPROVED-Authorization for Out of State Travel-Mayor Gonzalez.

Public Comment
None

The Council by motion of Mayor pro tem Martinez to approve item G-3. The motion was seconded
by Council Member Melendez and approved by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO, MELENDEZ
NONE
NONE
NONE

Item G-6
6.

Pulled by Resident Rocha
SUBJECT:
Project.

APPROVED-Final Acceptance for Sanger Fire Station Remodel

Public Comment
None

The Council by motion of Council Member Montelongo to approve item G-6. The motion was
seconded by Mayor pro tem Martinez and approved by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO, MELENDEZ
NONE
NONE
NONE

Item G-8
8.

Pulled by Council Member Hurtado
SUBJECT:
APPROVED-Approval of Sole Source Agreement with Blue Voice, Inc.
for Closed-Loop Artificial Intelligence Knowledge and Decision-Support Platform
for Police and Fire Departments.

Public Comment

Two member of the public spoke

The Council by motion of Mayor pro tem Martinez to approve item G-8. The motion was seconded
by Council Member Melendez and approved by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO, MELENDEZ
NONE
NONE
NONE
Page 9

Page 10 of 179

City Council Meeting Minutes
February 5, 2026
Page 4

Item G-14
14.

Pulled by Resident Rocha
SUBJECT:
APPROVED-Authorization of City Manager for direct contract
administration for specified agreements, with the exception of Subtopic (c).

Public Comment

One member of the public spoke

The Council by motion of Council Member Montelongo to approve item G-14. The motion was
seconded by Mayor pro tem Martinez and approved by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, MONTELONGO, MELENDEZ
NONE
HURTADO
NONE

H. DEPARTMENT REPORTS

I.

1.

SUBJECT:
INFORMATIONAL ONLY -Investment Report for the quarter
ended December 31, 2025

2.

SUBJECT:
PULLED FOR FUTURE DATE-Public Safety Sales Tax Gang/Drug
Prevention/ Intervention Services Grant Program Awards

CITY MANAGER/STAFF COMMUNICATION

Updates given by City Manager, Nathan Olson

J. REPORTS AND MATTERS INITIATED BY CITY COUNCIL MEMBERS

Updates given by Mayor Pro Tem Martinez, Council Member Hurtado, Council Member
Melendez, Council Member Montelongo and Mayor Gonzalez

K. ADJOURNMENT
Being no further business, the Council adjourned their meeting at 7:59 pm.
ATTEST:

Amanda Champion, Deputy City Clerk

Page 10

Page 11 of 179

For the Meeting of: February 19, 2026
Agenda Item No:

CITY OF SANGER

E-2

REPORT TO THE CITY COUNCIL
To:

Mayor and City Council

From:

Karla Camarena, Finance Manager

Subject:

Approval of Payroll Checks- January 2026

RECOMMENDATION:
That the City Council approve the payroll for the month of January, including Direct
Deposit Nos. 68711 through 69098, Payroll Check Nos. 60744 through 60782, and Benefit
Check Nos. 2182 through 2189.

Prepared by: Lina Martinez _
REVIEW:

City Manager: _NCO_______

TYPE OF ITEM:

X
X
____
____
____

Approved by: Nathan Olson_________________

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Finance: ___VH_____

COUNCIL ACTION:  APPROVED

City Attorney: ________

 DENIED

____
____
____
____

 NO ACTION

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 11

Page 12 of 179

pyChkLst
12/31/2025

Page: 1

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68711
68712
68713
68714
68715
68716
68717
68718
68719
68720
68721
68722
68723
68724
68725
68726
68727
68728
68729
68730
68731
68732
68733
68734
68735
68736
68737
68738
68739
68740
68741
68742
68743
68744
68745
68746
68747
68748

1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026

Employee #

Name

CHAMPION, AMANDA
DELGADO, SIERRA
JACKSON, BRIONNE
MARTINEZ, LINA
OLSON, NATHAN
GONZALEZ, FRANK G
MARTINEZ, DANIEL
MELENDEZ, DOLORES
MONTELONGO, MICHAEL A
HARPER, JESALYN
BARRAGAN, CASIMIRO
CUEVAS, ERIC
GOGGINS, JOSHUA
IRAZOQUI, MARIO
MURPHY, ROSE
SANDOVAL, PAUL
TOVAR, CARLOS
VIDRIO, JAVIER
CAMARENA, KARLA D.
CASILLAS-TORRES, SMALYNNE
DE ORTA, MICHELLE
FLORIAN, STEPHANIE
HARMON, VIRGINIA
NORIEGA, LESLIE
PEREZ ZUNIGA, MAYRA E
RAMIREZ, MICHELE
WAHL, LEICA KATHRINA LACAY
ALDAZ, MARCO
ALONSO, JULIA
CASTELLANOS, LINDSAY
CORONADO JR, JESUS
CUELLAR, ADRIANA
DELGADILLO, ANGEL
DOLAN, HAYDEN
ELLIS, SKYLER
ESCOBAR, MICHAEL
HOULE, BAILEY
JACKSON, COLBY

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

2,876.78
2,342.26
2,301.60
1,917.03
5,107.64
307.56
312.56
312.56
312.56
161.61
1,555.57
1,709.01
3,370.74
1,737.82
1,537.44
2,077.71
2,131.62
584.42
3,532.34
1,666.95
1,292.30
1,591.41
3,396.77
584.11
1,417.76
1,356.02
2,202.13
2,542.88
3,936.97
2,622.03
4,244.10
1,473.42
2,306.30
3,071.08
2,758.25
1,876.30
2,390.50
1,581.52

Page 12

Page: 1

Page 13 of 179

pyChkLst
12/31/2025

Page: 2

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68749
68750
68751
68752
68753
68754
68755
68756
68757
68758
68759
68760
68761
68762
68763
68764
68765
68766
68767
68768
68769
68770
68771
68772
68773
68774
68775
68776
68777
68778
68779
68780
68781
68782
68783
68784
68785
68786

1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026

Employee #

Name

JAECKEL, AVA
JONES, ANDY
LANG, JUSTIN
LORENTE, RYAN
MCWILLIAMS, SOFIA
MIRELES FLORES, MARIA
PALLAS, MICHAEL L
PISCHING, MARK G
PITTS, CRAIG
SALAZAR, GARRETT
SPANGLE, JENNIFER
TARASCOU, GREGORY
TREVINO, SANDRA
VELASQUEZ, SHERRY
WADDLE, CHRISTOPHER A.
WASHBURN, HAIDYN
WILLIAMS, KENNETH D.
WILSON, TODD
ZEPEDA, LEONARDO
ACEVES CRUZ, JULIAN
ARGUELLO, SERGIO
AYERS III, JOHN
BANDA-TOVAR, JOEL
BARRAGAN, MELISSA
BERNAL, SADIE
BISE, JEFFREY L.
BOUST, JASON
BURKDOLL, MARISA
CAMPBELL, SARAH L
CASTREJON, EDDIE
DIAZ, HENRY
EDWARDS, SHAELA
FRANCO, RICHARD
GARCIA, FERNANDO
GARZA, RAMIRO
GUILLEN, ROSARIO
HERNANDEZ, ANDREINA
HUGHES, TOBIAS

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

3,240.47
6,331.14
2,341.25
4,977.51
2,651.73
2,784.43
2,779.95
2,493.10
5,770.80
2,351.92
671.14
3,382.39
2,228.27
3,307.16
6,628.83
2,140.64
4,857.39
5,045.13
3,260.06
4,896.78
3,633.61
1,828.56
2,342.28
2,096.42
1,847.74
3,414.93
3,556.18
1,899.07
1,233.17
20,018.23
2,665.47
4,708.08
2,020.19
2,158.86
4,799.83
3,106.50
1,591.63
1,640.83

Page 13

Page: 2

Page 14 of 179

pyChkLst
12/31/2025

Page: 3

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68787
68788
68789
68790
68791
68792
68793
68794
68795
68796
68797
68798
68799
68800
68801
68802
68803
68804
68805
68806
68807
68808
68809
68810
68811
68812
68813
68814
68815
68816
68817
68818
68819
68820
68821
68822
68823
68824

1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026

Employee #

Name

INOSTROS, JESSICA
JOHNSON, JOSHUA D
JONES, KIMBERLY M.
KAUR, MANDEEP
MEDINA, JOSE
MENDEZ, GERARD
MORALES, JESSE
MORENO, LOUIS A
MUNOZ, BERTHA J
NELSON, AMANDA M
PACHECO, JOSE
REYNOLDS, JOHN
ROARK, TYLER
RODRIGUEZ, JULIAN R
RYAN, NICOLE
SANCHEZ, KELSEY
SOTO, JOSE O.
THAO, MENOU A
TORRES, ROBERT C
TREVINO, CYNTHIA
VARELA, TERRI
WELCH, PAUL M.
YAMBUPAH, ANGELA C
ACOSTA, JAVIER
AVALOS, JORGE
BARBA CORTES, ERIKA
CABRERA, MARTIN
CHOLICO, EDGAR
EGGLESTON, STEVEN
FLUETSCH, JOHN
GONZALEZ, EDDIE
GONZALEZ, JUAN
HUERTA, PAUL
IRAZOQUI, DANIEL T
JASSO, GEORGE
LOPEZ, ALEX
LOPEZ, DIEGO
MARTIN, RAYMOND

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

1,953.45
3,764.19
2,233.06
1,868.43
7,342.23
2,482.15
3,441.73
4,261.92
3,058.22
3,172.87
10,795.83
3,260.39
2,211.49
4,674.24
1,587.44
3,379.69
2,556.79
4,020.13
3,794.33
2,107.28
1,094.48
1,871.35
4,674.23
2,190.68
1,357.59
2,280.64
1,297.24
2,323.79
1,735.15
2,378.45
3,122.95
1,448.11
1,678.48
1,479.71
2,819.72
1,907.33
2,343.73
2,093.76

Page 14

Page: 3

Page 15 of 179

pyChkLst
12/31/2025

Page: 4

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68825
68826
68827
68828
68829
68830
68831
68832
68833
68834
68835
68836
68837
68838
68839
68840

1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026

Employee #

Name

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

1,635.57
1,515.42
1,271.07
2,165.46
5,655.04
1,559.20
1,899.55
685.51
576.95
1,828.86
186.96
450.11
277.72
23.21
1,253.70
2,054.53

Employee Check Totals

0.00

346,303.41

Bank dirdep Totals (130 Forms)

0.00

346,303.41

MAZARIEGO, MANUEL
ORONA, CATARINO
PIMENTEL, SEAN
REYES, ANTONIO P
ROSALES, ESPERANZA
SANTOS, WILLIAM
WOODS, STEVE
HERNANDEZ, KEITH
MENDOZA, GRICELDA
ALBARRAN-PEREZ, VIANEY
BARAJAS, LIZETTE
DENISTON, CATALINA
PETRILLE, BRIANA
PINA, CARLOS
VASQUEZ, APRIL
ZAMORA, JOAQUIN

Page 15

Page: 4

Page 16 of 179

pyChkLst
12/31/2025

Page: 5

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Bank: pybank - WESTAMERICA BANK
Check #

Date

60744
60745
60746
60747
60748
60749
60750
60751
60752
60753
60754
60755

1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026

Employee #

Name

Check Amt

Direct Deposit

HURTADO, ESMERALDA
BOUASAVANH, CHAIDED
AGUILAR, ANTONIO
CARTER, KEVIN T
ECHEVERRIA JR, VICTOR R
LOPEZ, MARY LOU
LITTLE, LYNDSEE
WILHELM, AUBREE
AYALA, RAMIRO
PEREZ, SILVESTRE
REYES, ALEJANDRO
PRADO, BRANDON

307.56
161.61
46.17
161.61
42.35
46.17
2,869.92
2,122.41
13,742.69
2,735.48
1,267.49
669.86

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

24,173.32

0.00

Check Amt

Direct Deposit

98.86
3,191.17
954.50
2,798.87
1,201.52
410.41

0.00
0.00
0.00
0.00
0.00
0.00

Total

8,655.33

0.00

Payee Totals

8,655.33

0.00

Bank pybank Totals (18 Forms)

32,828.65

0.00

Employee Check Totals

Bank: pybank - WESTAMERICA BANK
Benefit Checks
Check #

Date

60756
60757
60758
60759
60760
60761

1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026
1/2/2026

Payee #

Name

AFLAC
AMERICAN FIDELITY ASSURANCE
SANGER FIRE ASSOCIATION, FOOD
SANGER POLICE ASSOCIATION, DUE
STATE DISBURSEMENT UNIT
STATIONARY ENGINEERS, LOCAL 39

Page 16

Page: 5

Page 17 of 179

pyChkLst
12/31/2025

Page: 6

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Bank: wire - FEDERAL TAX PAYMENT
Benefit Checks
Check #

2182
2183
2184
2185

Date

1/2/2026
1/2/2026
1/2/2026
1/2/2026

Next Step: Account Posting (AP)

Payee #

Name

Check Amt

Direct Deposit

WESTAMERICA BANK
EMPLOYMENT DEVELOPMENT DEPT
I.C.M.A RETIREMENT TRUST 457
CALPERS 457 PLAN

122,557.47
19,415.62
1,506.70
2,899.76

0.00
0.00
0.00
0.00

Total

146,379.55

0.00

Payee Totals

146,379.55

0.00

Bank wire Totals (4 Forms)

146,379.55

0.00

Grand Total

179,208.20

346,303.41

Totals Checks and Direct Deposit (152 Forms)

525,511.61

Pay Period is Open (Locked)

Page 17

Page: 6

Page 18 of 179

pyChkLst
12/31/2025

Page: 7

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Benefit Checks - pending for pay period from 12/27/25 to 01/09/26 ID: 1,183
Check #

Date

Payee #

Name

Amount

1/16/2026
030
Source pay period: 12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26

MID-MANAGEMENT ASSN, DUES-MM
Doc source: midmgmtpay
ID: 1,182
ID: 1,182
midmgmtpay
ID: 1,182
midmgmtpay
ID: 1,182
midmgmtpay
ID: 1,182
midmgmtpay

1/16/2026
059
Source pay period: 12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26

TEXAS LIFE INSURANCE COMPANY
Doc source: hlthpay
ID: 1,182
ID: 1,182
hlthpay
ID: 1,182
hlthpay
ID: 1,182
hlthpay

1/16/2026
041
Source pay period: 12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26

GENERAL EMPLOYEES ASSN, DUES GEN EMPS
Doc source: genemppay
Bended code: gendue
ID: 1,182
ID: 1,182
genemppay
gendue

Bended code: mmdues
mmdues
mmdues
mmdues
mmdues

Fund: 101
261
611
621
712
Check Total:

Bended code: txslfe
txslfe
txslfe
txslfe

Fund: 101
208
261
712
Check Total:

Fund: 101
712
Check Total:

1/16/2026
008
Source pay period: 12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26

SANGER FIRE ASSOCIATION, DUES-FIRE
Doc source: firduepay
Bended code: freasn
ID: 1,182
ID: 1,182
firduepay
freasn
ID: 1,182
firduepay
freasn

Fund: 101
208
261
Check Total:

1/16/2026
012
Source pay period: 12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26

EXECUTIVE MGMT ORGANIZATION, EXE MGMT-DU
Doc source: sanexepay
Bended code: exdues
ID: 1,182
ID: 1,182
sanexepay
exdues

Fund: 101
712

114.22
19.50
20.52
21.26
39.00
214.50
156.94
169.07
11.24
86.27
423.52
5.00
5.00
10.00
1,137.12
500.00
75.00
1,712.12
80.00
40.00

Check Total:

120.00

Organization Total:

2,480.14

Pay Period Total (12/27/25 to 01/09/26 ID: 1,183):

2,480.14

Benefit Checks Grand Total:

2,480.14

Page 18

Page: 7

Page 19 of 179

pyChkLst
12/31/2025

Page: 8

Payroll Final Check List
1:28PM

City of Sanger
12/13/2025 to 12/26/2025- Type 1 Cycle 26

Page 19

Page: 8

Page 20 of 179

pyChkLst
01/15/2026

Page: 1

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68841
68842
68843
68844
68845
68846
68847
68848
68849
68850
68851
68852
68853
68854
68855
68856
68857
68858
68859
68860
68861
68862
68863
68864
68865
68866
68867
68868
68869
68870
68871
68872
68873
68874
68875
68876
68877
68878

1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026

Employee #

Name

CHAMPION, AMANDA
DELGADO, SIERRA
JACKSON, BRIONNE
MARTINEZ, LINA
OLSON, NATHAN
GONZALEZ, FRANK G
MARTINEZ, DANIEL
MELENDEZ, DOLORES
MONTELONGO, MICHAEL A
BARRAGAN, CASIMIRO
CUEVAS, ERIC
GOGGINS, JOSHUA
IRAZOQUI, MARIO
MURPHY, ROSE
SANDOVAL, PAUL
TOVAR, CARLOS
VIDRIO, JAVIER
CAMARENA, KARLA D.
CASILLAS-TORRES, SMALYNNE
DE ORTA, MICHELLE
FLORIAN, STEPHANIE
HARMON, VIRGINIA
NORIEGA, LESLIE
PEREZ ZUNIGA, MAYRA E
RAMIREZ, MICHELE
WAHL, LEICA KATHRINA LACAY
ALDAZ, MARCO
ALONSO, JULIA
CASTELLANOS, LINDSAY
CORONADO JR, JESUS
CUELLAR, ADRIANA
DELGADILLO, ANGEL
DOLAN, HAYDEN
ELLIS, SKYLER
ESCOBAR, MICHAEL
HOULE, BAILEY
JACKSON, COLBY
JAECKEL, AVA

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

3,882.38
2,300.70
2,267.42
1,917.03
4,654.53
307.56
312.56
312.56
312.56
1,555.57
1,709.01
3,297.11
1,887.46
1,786.80
2,077.71
2,131.62
584.42
4,801.34
2,161.78
1,463.66
1,701.43
3,323.14
833.81
1,725.21
1,356.02
2,137.50
2,336.45
3,355.54
2,440.19
3,905.80
1,764.79
2,134.62
2,969.98
2,256.88
2,080.38
2,540.97
1,792.73
2,182.47

Page 20

Page: 1

Page 21 of 179

pyChkLst
01/15/2026

Page: 2

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68879
68880
68881
68882
68883
68884
68885
68886
68887
68888
68889
68890
68891
68892
68893
68894
68895
68896
68897
68898
68899
68900
68901
68902
68903
68904
68905
68906
68907
68908
68909
68910
68911
68912
68913
68914
68915
68916

1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026

Employee #

Name

JONES, ANDY
LANG, JUSTIN
LORENTE, RYAN
MCWILLIAMS, SOFIA
MIRELES FLORES, MARIA
PALLAS, MICHAEL L
PISCHING, MARK G
PITTS, CRAIG
SALAZAR, GARRETT
SPANGLE, JENNIFER
TARASCOU, GREGORY
TREVINO, SANDRA
VELASQUEZ, SHERRY
WADDLE, CHRISTOPHER A.
WASHBURN, HAIDYN
WILHELM, AUBREE
WILLIAMS, KENNETH D.
WILSON, TODD
ZEPEDA, LEONARDO
ACEVES CRUZ, JULIAN
ARGUELLO, SERGIO
AYERS III, JOHN
BANDA-TOVAR, JOEL
BARRAGAN, MELISSA
BERNAL, SADIE
BISE, JEFFREY L.
BOUST, JASON
BURKDOLL, MARISA
CAMPBELL, SARAH L
CASTREJON, EDDIE
DIAZ, HENRY
EDWARDS, SHAELA
FRANCO, RICHARD
GARCIA, FERNANDO
GARZA, RAMIRO
GUILLEN, ROSARIO
HERNANDEZ, ANDREINA
HUGHES, TOBIAS

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

4,263.64
1,868.13
3,411.91
1,934.79
2,699.63
2,905.05
2,677.95
4,471.26
2,185.20
861.18
3,356.23
2,191.34
2,277.50
7,606.04
1,877.13
2,176.52
3,711.47
4,179.75
1,948.38
7,289.35
6,063.56
2,246.21
7,346.95
4,620.05
2,345.70
9,756.65
10,886.43
2,412.75
1,372.44
7,203.70
29,752.34
10,133.14
4,617.24
15,701.92
11,399.14
4,188.10
1,557.92
6,603.55

Page 21

Page: 2

Page 22 of 179

pyChkLst
01/15/2026

Page: 3

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68917
68918
68919
68920
68921
68922
68923
68924
68925
68926
68927
68928
68929
68930
68931
68932
68933
68934
68935
68936
68937
68938
68939
68940
68941
68942
68943
68944
68945
68946
68947
68948
68949
68950
68951
68952
68953
68954

1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026

Employee #

Name

INOSTROS, JESSICA
JOHNSON, JOSHUA D
JONES, KIMBERLY M.
KAUR, MANDEEP
MEDINA, JOSE
MENDEZ, GERARD
MORALES, JESSE
MORENO, LOUIS A
MUNOZ, BERTHA J
NELSON, AMANDA M
REYNOLDS, JOHN
ROARK, TYLER
RODRIGUEZ, JULIAN R
RYAN, NICOLE
SANCHEZ, KELSEY
SOTO, JOSE O.
THAO, MENOU A
TORRES, ROBERT C
TREVINO, CYNTHIA
VARELA, TERRI
WELCH, PAUL M.
YAMBUPAH, ANGELA C
ACOSTA, JAVIER
AVALOS, JORGE
BARBA CORTES, ERIKA
CABRERA, MARTIN
CHOLICO, EDGAR
EGGLESTON, STEVEN
FLUETSCH, JOHN
GONZALEZ, EDDIE
GONZALEZ, JUAN
HUERTA, PAUL
IRAZOQUI, DANIEL T
JASSO, GEORGE
LOPEZ, ALEX
LOPEZ, DIEGO
MARTIN, RAYMOND
MAZARIEGO, MANUEL

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

5,788.44
9,699.96
2,959.43
2,560.89
8,021.95
4,201.67
7,978.02
7,612.08
7,750.64
5,839.88
3,233.63
6,051.08
5,674.62
1,975.60
6,451.49
3,913.30
4,741.04
6,132.64
11,596.10
1,054.89
3,249.30
6,405.48
2,432.61
1,521.09
2,280.64
1,308.36
1,999.95
1,735.15
2,325.68
2,683.55
1,448.11
1,678.48
1,533.99
2,819.72
1,837.86
2,368.45
2,056.83
1,641.27

Page 22

Page: 3

Page 23 of 179

pyChkLst
01/15/2026

Page: 4

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68955
68956
68957
68958
68959
68960
68961
68962
68963
68964
68965
68966
68967
68968
68969

1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026

Employee #

Name

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

1,483.52
1,334.92
2,578.85
3,655.64
1,559.20
2,397.82
762.87
721.18
1,743.87
21.57
543.53
389.63
61.88
1,253.70
2,054.53

Employee Check Totals

0.00

457,788.51

Bank dirdep Totals (129 Forms)

0.00

457,788.51

ORONA, CATARINO
PIMENTEL, SEAN
REYES, ANTONIO P
ROSALES, ESPERANZA
SANTOS, WILLIAM
WOODS, STEVE
HERNANDEZ, KEITH
MENDOZA, GRICELDA
ALBARRAN-PEREZ, VIANEY
BARAJAS, LIZETTE
DENISTON, CATALINA
PETRILLE, BRIANA
PINA, CARLOS
VASQUEZ, APRIL
ZAMORA, JOAQUIN

Page 23

Page: 4

Page 24 of 179

pyChkLst
01/15/2026

Page: 5

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Bank: pybank - WESTAMERICA BANK
Check #

Date

60763
60764
60765
60766
60767
60768
60769
60770

1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026

Employee #

Name

Check Amt

Direct Deposit

266.00
1,862.68
2,165.74
1,885.07
8,428.31
2,735.48
1,315.14
612.23

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

19,270.65

0.00

Check Amt

Direct Deposit

98.86
3,253.86
240.00
31.90
20.00
429.00
3,424.24
954.50
1,972.11
994.14
410.41
847.04

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Total

12,676.06

0.00

Payee Totals

12,676.06

0.00

Bank pybank Totals (20 Forms)

31,946.71

0.00

HURTADO, ESMERALDA
FRIES, MATTHEW
LITTLE, LYNDSEE
MENDEZ, OSCAR
AYALA, RAMIRO
PEREZ, SILVESTRE
REYES, ALEJANDRO
PRADO, BRANDON
Employee Check Totals

Bank: pybank - WESTAMERICA BANK
Benefit Checks
Check #

Date

60771
60772
60773
60774
60775
60776
60777
60778
60779
60780
60781
60782

1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026
1/16/2026

Payee #

Name

026
057
012
021
041
030
008
052
010
045
007
059

AFLAC
AMERICAN FIDELITY ASSURANCE
EXECUTIVE MGMT ORGANIZATION, E
FRANCHISE TAX BOARD
GENERAL EMPLOYEES ASSN, DUES G
MID-MANAGEMENT ASSN, DUES-MM
SANGER FIRE ASSOCIATION, DUESSANGER FIRE ASSOCIATION, FOOD
SANGER POLICE ASSOCIATION, DUE
STATE DISBURSEMENT UNIT
STATIONARY ENGINEERS, LOCAL 39
TEXAS LIFE INSURANCE COMPANY

Page 24

Page: 5

Page 25 of 179

pyChkLst
01/15/2026

Page: 6

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Bank: wire - FEDERAL TAX PAYMENT
Benefit Checks
Check #

2186
2187
2188
2189

Date

1/16/2026
1/16/2026
1/16/2026
1/16/2026

Next Step: Account Posting (AP)

Payee #

Name

Check Amt

Direct Deposit

003
004
006
054

WESTAMERICA BANK
EMPLOYMENT DEVELOPMENT DEPT
I.C.M.A RETIREMENT TRUST 457
CALPERS 457 PLAN

134,108.65
25,374.94
1,507.57
4,210.99

0.00
0.00
0.00
0.00

Total

165,202.15

0.00

Payee Totals

165,202.15

0.00

Bank wire Totals (4 Forms)

165,202.15

0.00

Grand Total

197,148.86

457,788.51

Totals Checks and Direct Deposit (153 Forms)

654,937.37

Pay Period is Open (Locked)

Page 25

Page: 6

Page 26 of 179

pyChkLst
01/15/2026

Page: 7

Payroll Final Check List
11:19AM

City of Sanger
12/27/2025 to 01/09/2026- Type 2 Cycle 26

Benefit Checks - pending for pay period from 01/24/26 to 02/06/26 ID: 1,185
Check #

Date

Payee #

2/13/2026
010
Source pay period: 12/27/2025 to 01/09/2026 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/27/2025 to 01/09/2026 Cycle 26
12/27/2025 to 01/09/2026 Cycle 26

Name

Amount

SANGER POLICE ASSOCIATION, DUES-POLICE
Doc source: polassnpay
Bended code: poldue
ID: 1,183
ID: 1,210
polassnpay
poldue
ID: 1,182
polassnpay
poldue
ID: 1,183
polassnpay
poldue
ID: 1,183
polassnpay
poldue

Fund: 101
101
101
208
261

595.04
76.27
-76.27
77.33
77.33

Check Total:

749.70

Organization Total:

749.70

Pay Period Total (01/24/26 to 02/06/26 ID: 1,185):

749.70

Benefit Checks Grand Total:

749.70

Page 26

Page: 7

Page 27 of 179

pyChkLst
01/29/2026

Page: 1

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

68970
68971
68972
68973
68974
68975
68976
68977
68978
68979
68980
68981
68982
68983
68984
68985
68986
68987
68988
68989
68990
68991
68992
68993
68994
68995
68996
68997
68998
68999
69000
69001
69002
69003
69004
69005
69006
69007

1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026

Employee #

Name

CHAMPION, AMANDA
DELGADO, SIERRA
JACKSON, BRIONNE
MARTINEZ, LINA
OLSON, NATHAN
GONZALEZ, FRANK G
MARTINEZ, DANIEL
MELENDEZ, DOLORES
MONTELONGO, MICHAEL A
BARRAGAN, CASIMIRO
CUEVAS, ERIC
GOGGINS, JOSHUA
IRAZOQUI, MARIO
MURPHY, ROSE
SANDOVAL, PAUL
TOVAR, CARLOS
VIDRIO, JAVIER
CAMARENA, KARLA D.
CASILLAS-TORRES, SMALYNNE
DE ORTA, MICHELLE
FLORIAN, STEPHANIE
HARMON, VIRGINIA
NORIEGA, LESLIE
PEREZ ZUNIGA, MAYRA E
RAMIREZ, MICHELE
WAHL, LEICA KATHRINA LACAY
ALDAZ, MARCO
ALONSO, JULIA
CASTELLANOS, LINDSAY
CORONADO JR, JESUS
CUELLAR, ADRIANA
DELGADILLO, ANGEL
DOLAN, HAYDEN
ELLIS, SKYLER
ESCOBAR, MICHAEL
HOULE, BAILEY
JACKSON, COLBY
JAECKEL, AVA

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

2,881.79
0.00
2,443.42
2,100.55
4,671.59
127.86
127.86
127.86
127.86
1,555.57
1,709.01
3,328.66
1,816.58
1,537.44
2,077.71
2,131.62
584.42
4,869.70
2,378.65
1,351.21
1,660.35
3,354.70
584.11
1,550.56
1,454.58
2,212.56
2,681.29
3,065.72
1,668.27
5,578.44
1,621.70
1,905.35
3,140.48
2,093.70
1,524.27
2,400.75
1,517.11
1,890.94

Page 27

Page: 1

Page 28 of 179

pyChkLst
01/29/2026

Page: 2

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

69008
69009
69010
69011
69012
69013
69014
69015
69016
69017
69018
69019
69020
69021
69022
69023
69024
69025
69026
69027
69028
69029
69030
69031
69032
69033
69034
69035
69036
69037
69038
69039
69040
69041
69042
69043
69044
69045

1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026

Employee #

Name

JONES, ANDY
LANG, JUSTIN
LORENTE, RYAN
MCWILLIAMS, SOFIA
MIRELES FLORES, MARIA
PALLAS, MICHAEL L
PISCHING, MARK G
PITTS, CRAIG
SALAZAR, GARRETT
SPANGLE, JENNIFER
TARASCOU, GREGORY
TREVINO, SANDRA
VELASQUEZ, SHERRY
WADDLE, CHRISTOPHER A.
WASHBURN, HAIDYN
WILHELM, AUBREE
WILLIAMS, KENNETH D.
WILSON, TODD
ZEPEDA, LEONARDO
ACEVES CRUZ, JULIAN
ARGUELLO, SERGIO
AYERS III, JOHN
BANDA-TOVAR, JOEL
BARRAGAN, MELISSA
BERNAL, SADIE
BISE, JEFFREY L.
BOUST, JASON
BURKDOLL, MARISA
CAMPBELL, SARAH L
CASTREJON, EDDIE
DIAZ, HENRY
EDWARDS, SHAELA
FRANCO, RICHARD
GARCIA, FERNANDO
GARZA, RAMIRO
GUILLEN, ROSARIO
HERNANDEZ, ANDREINA
INOSTROS, JESSICA

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

3,213.59
1,618.45
3,357.58
2,228.29
3,029.00
3,008.58
2,634.07
3,258.15
2,140.73
861.18
7,889.02
2,249.75
2,052.33
3,469.26
1,659.87
2,608.70
3,537.99
3,935.49
2,963.84
4,364.29
4,576.82
2,621.28
5,303.63
3,795.11
2,595.97
4,918.58
5,150.41
2,621.30
1,191.90
5,718.50
5,496.91
4,724.96
3,220.09
4,672.32
7,603.42
4,705.69
2,269.76
4,700.10

Page 28

Page: 2

Page 29 of 179

pyChkLst
01/29/2026

Page: 3

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

69046
69047
69048
69049
69050
69051
69052
69053
69054
69055
69056
69057
69058
69059
69060
69061
69062
69063
69064
69065
69066
69067
69068
69069
69070
69071
69072
69073
69074
69075
69076
69077
69078
69079
69080
69081
69082
69083

1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026

Employee #

Name

JOHNSON, JOSHUA D
JONES, KIMBERLY M.
KAUR, MANDEEP
MEDINA, JOSE
MENDEZ, GERARD
MORALES, JESSE
MORENO, LOUIS A
MUNOZ, BERTHA J
NELSON, AMANDA M
REYNOLDS, JOHN
ROARK, TYLER
RODRIGUEZ, JULIAN R
RYAN, NICOLE
SANCHEZ, KELSEY
SOTO, JOSE O.
THAO, MENOU A
TORRES, ROBERT C
TREVINO, CYNTHIA
VARELA, TERRI
WELCH, PAUL M.
YAMBUPAH, ANGELA C
ACOSTA, JAVIER
AVALOS, JORGE
BARBA CORTES, ERIKA
CABRERA, MARTIN
CHOLICO, EDGAR
EGGLESTON, STEVEN
FLUETSCH, JOHN
GONZALEZ, EDDIE
GONZALEZ, JUAN
HUERTA, PAUL
IRAZOQUI, DANIEL T
JASSO, GEORGE
LOPEZ, ALEX
LOPEZ, DIEGO
MARTIN, RAYMOND
MAZARIEGO, MANUEL
ORONA, CATARINO

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

6,364.95
2,958.62
2,491.28
4,819.78
3,396.70
4,878.43
5,920.90
3,920.39
3,726.71
3,260.39
4,298.37
4,246.80
1,696.90
3,998.21
3,837.51
3,992.39
4,831.11
4,735.61
1,861.85
2,469.42
4,441.79
2,215.46
1,401.34
2,280.64
1,348.69
2,382.11
1,759.93
2,325.68
2,683.55
1,573.56
1,762.26
1,610.22
2,819.72
2,212.97
2,202.79
2,087.84
1,790.58
1,603.82

Page 29

Page: 3

Page 30 of 179

pyChkLst
01/29/2026

Page: 4

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Bank: dirdep - WESTAMERICA BANK
Check #

Date

69084
69085
69086
69087
69088
69089
69090
69091
69092
69093
69094
69095
69096
69097
69098

1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026

Employee #

Name

Check Amt

Direct Deposit

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

1,417.44
2,068.33
3,842.99
1,692.80
1,923.98
904.92
865.42
1,743.87
17.97
416.14
464.64
66.33
244.26
1,253.70
2,324.75

Employee Check Totals

0.00

347,277.96

Bank dirdep Totals (129 Forms)

0.00

347,277.96

PIMENTEL, SEAN
REYES, ANTONIO P
ROSALES, ESPERANZA
SANTOS, WILLIAM
WOODS, STEVE
HERNANDEZ, KEITH
MENDOZA, GRICELDA
ALBARRAN-PEREZ, VIANEY
BARAJAS, LIZETTE
DENISTON, CATALINA
JIMENEZ, AUBREY A
PETRILLE, BRIANA
PINA, CARLOS
VASQUEZ, APRIL
ZAMORA, JOAQUIN

Page 30

Page: 4

Page 31 of 179

pyChkLst
01/29/2026

Page: 5

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Bank: pybank - WESTAMERICA BANK
Check #

Date

60783
60784
60785
60786
60787
60788
60789
60790
60791
60792
60793
60794
60795
60796
60797

1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026

Employee #

Name

Check Amt

Direct Deposit

122.86
2,382.18
1,661.96
1,806.67
1,628.40
5,069.21
3,407.17
2,735.48
1,442.17
82.43
82.43
39.24
98.12
514.51
78.50

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

21,151.33

0.00

Check Amt

Direct Deposit

98.86
40.75
31.90
954.50
916.14

0.00
0.00
0.00
0.00
0.00

Total

2,042.15

0.00

Payee Totals

2,042.15

0.00

Bank pybank Totals (20 Forms)

23,193.48

0.00

HURTADO, ESMERALDA
DAVIS, THOMAS ETHAN
FRIES, MATTHEW
LITTLE, LYNDSEE
MENDEZ, OSCAR
AYALA, RAMIRO
HUGHES, TOBIAS
PEREZ, SILVESTRE
REYES, ALEJANDRO
CASTRO ROSALES, NANCY
AGUILAR, JOAQUIN
MARTINEZ, ALYSSA
MARTINEZ, XAVIER
PRADO, BRANDON
URIETA, AMY
Employee Check Totals

Bank: pybank - WESTAMERICA BANK
Benefit Checks
Check #

Date

60798
60799
60800
60801
60802

1/30/2026
1/30/2026
1/30/2026
1/30/2026
1/30/2026

Payee #

Name

026
057
021
052
045

AFLAC
AMERICAN FIDELITY ASSURANCE
FRANCHISE TAX BOARD
SANGER FIRE ASSOCIATION, FOOD
STATE DISBURSEMENT UNIT

Page 31

Page: 5

Page 32 of 179

pyChkLst
01/29/2026

Page: 6

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Bank: wire - FEDERAL TAX PAYMENT
Benefit Checks
Check #

2190
2191
2192
2193

Date

1/30/2026
1/30/2026
1/30/2026
1/30/2026

Next Step: Account Posting (AP)

Payee #

Name

Check Amt

Direct Deposit

003
004
006
054

WESTAMERICA BANK
EMPLOYMENT DEVELOPMENT DEPT
I.C.M.A RETIREMENT TRUST 457
CALPERS 457 PLAN

115,919.11
19,883.83
1,489.88
3,583.46

0.00
0.00
0.00
0.00

Total

140,876.28

0.00

Payee Totals

140,876.28

0.00

Bank wire Totals (4 Forms)

140,876.28

0.00

Grand Total

164,069.76

347,277.96

Totals Checks and Direct Deposit (153 Forms)

511,347.72

Pay Period is Open (Locked)

Page 32

Page: 6

Page 33 of 179

pyChkLst
01/29/2026

Page: 7

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26

Benefit Checks - pending for pay period from 01/24/26 to 02/06/26 ID: 1,185
Check #

Date

Payee #

Name

2/13/2026
010
Source pay period: 12/13/2025 to 12/26/2025 Cycle 26
12/13/2025 to 12/26/2025 Cycle 26
12/27/2025 to 01/09/2026 Cycle 26
12/27/2025 to 01/09/2026 Cycle 26
12/27/2025 to 01/09/2026 Cycle 26

Amount

SANGER POLICE ASSOCIATION, DUES-POLICE
Doc source: polassnpay
Bended code: poldue
ID: 1,182
ID: 1,210
polassnpay
poldue
ID: 1,183
polassnpay
poldue
ID: 1,183
polassnpay
poldue
ID: 1,183
polassnpay
poldue

Fund: 101
101
101
208
261

-76.27
76.27
595.04
77.33
77.33

Check Total:

749.70

Organization Total:

749.70

Pay Period Total (01/24/26 to 02/06/26 ID: 1,185):

749.70

Benefit Checks - pending for pay period from 02/07/26 to 02/20/26 ID: 1,186
Check #

Date

Payee #

2/27/2026
030
Source pay period: 01/10/2026 to 01/23/2026 Cycle 26
01/10/2026 to 01/23/2026 Cycle 26
01/10/2026 to 01/23/2026 Cycle 26
01/10/2026 to 01/23/2026 Cycle 26
01/10/2026 to 01/23/2026 Cycle 26

Name

MID-MANAGEMENT ASSN, DUES-MM
Doc source: midmgmtpay
ID: 1,184
ID: 1,184
midmgmtpay
ID: 1,184
midmgmtpay
ID: 1,184
midmgmtpay
ID: 1,184
midmgmtpay

Amount

Bended code: mmdues
mmdues
mmdues
mmdues
mmdues

Fund: 101
261
611
621
712
Check Total:

2/27/2026
041
Source pay period: 01/10/2026 to 01/23/2026 Cycle 26
01/10/2026 to 01/23/2026 Cycle 26

GENERAL EMPLOYEES ASSN, DUES GEN EMPS
Doc source: genemppay
Bended code: gendue
ID: 1,184
ID: 1,184
genemppay
gendue

Fund: 101
712
Check Total:

2/27/2026
012
Source pay period: 01/10/2026 to 01/23/2026 Cycle 26
01/10/2026 to 01/23/2026 Cycle 26

EXECUTIVE MGMT ORGANIZATION, EXE MGMT-DU
Doc source: sanexepay
Bended code: exdues
ID: 1,184
ID: 1,184
sanexepay
exdues

Fund: 101
712

135.14
19.50
20.18
20.18
39.00
234.00
5.00
5.00
10.00
80.00
40.00

Check Total:

120.00

Organization Total:

364.00

Page 33

Page: 7

Page 34 of 179

pyChkLst
01/29/2026

Page: 8

Payroll Final Check List
11:09AM

City of Sanger
01/10/2026 to 01/23/2026- Type 3 Cycle 26
Pay Period Total (02/07/26 to 02/20/26 ID: 1,186):

364.00

Benefit Checks Grand Total:

1,113.70

Page 34

Page: 8

Page 35 of 179

For the Meeting of: February 19, 2026
Agenda Item No.: E-3

CITY OF SANGER

REPORT TO THE CITY COUNCIL
To:

Mayor and City Council

From:

Karla Camarena, Finance Manager

Subject:

Warrants- January 2026

RECOMMENDATION:
Warrants, including Check Nos. 96331 through 96534, for the month of January 2026.

Prepared by: Lina Martinez

Approved by: _Nathan Olson_____________________

REVIEW: City Manager: _NCO_____
TYPE OF ITEM:

__X_
__X_
____
____
____

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Finance: __VH_____

City Attorney: ______

COUNCIL ACTION:  APPROVED  DENIED  NO ACTION

____
____
____
____

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 35

Page 36 of 179

apChklst

FinalGheck List
Gity of Sanger

0110912026 9:27:09AM

Bank
Check #
96331

96332
96333
96334
96335
96336

waap WESTAMERICA BANK

Date Vendor
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

VETS

lnvoice

lnv Date Description

95573

12t4t2025 VET CARE #170671

04418

2417 PET

11604

ADVENTIST HEALTH TOX 2676

10494
00025

LLC
ALERT-O-LITE, tNC.

04173
07024

96338
96339

96340
96341

96342
96343

96344
96345

119t2026

Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

Check Total
103.50

121312025 DRUG/ALCOHOL TESTING

1,111.00

1,111 .00

10t31t2025 oXYGEN
12t 16t2025 OXYGEN (MED|CAL)
1211912025 SUPPLIES FOR EQUIPMENT

293.59
127.00

599.70
127.00

ALL VALLEY SPRAY SERV 378207

1211212025 SVCS/ WEED ABATEMENT

2,175.00

2,175.00

AMERITAS

12t22t2025 DENTAL CLAIMS 12122125
12t15t2025 DENTAL CLAIMS 12112125
12t29t2025 DENTAL CLAIMS 12126125
't2t8t2025 DENTAL CLAIMS 1215125
1t30t2026 DENTALADMIN FEES JAN'26
12t19t2025 R&M/ NEUROS BLOWER-1

2,668.40
2,070.00
1,433.60
1 ,318.15
715.68
2,200.00

8,205.83
2,200.0o

SIGNAL LIGHT MAI NT/REPAI F
SIGNAL LIGHT MAINT/REPAI F
1 21 1 812025 LAB WATER ANALYS S

AIRGAS USA

5520520071

9167674829
0189167-tN

301379
301 379

0960

APGN INC

12958

BEAR ELECTRICAL SOLU 28749

1

Amount Paid
103.50

301379
301379
301 379
96337

Page:1

22992

11 I3OI2O25

306.11

13020

BURKDOLL, MARISA

REIMB

12t1t2025 GYM (DEC)

2,064.00
165.00
690.67
170.00
30.00
30.00

02285

CALED

300006884 lltl7t2025ECONOMICDEVELOPMENT"l

2,300.00

2,300.00

09934

CENCALAUTO & TRUCK DEC

11812026 AUTOMOTIVEPARTS

1,396.39

1,396.39

02464

CENTRAL VALLEY TOXIC( 343053

91912025 DRUG SCREEN

285.00

285.00

05051

CITY OF FRESNO

2,208.18
2,085.72
751.02

4,293.90
751.02

28735
00097

09872

BSK & ASSOCIATES INC. Ar32533

:

I

4132238

121 1612025 LAB:WATE R ANALYSI S

4t32544

1 21 1

I

COMCAST

11 I3OI2O25

812025 LAB:WATE R ANALYSI S

20010484

11 I 1212025

2001 0486

11 I 1212025

256937464

QTR4/FY25 TRAFFIC SIGNAL
QTR1 /FY26 TRAFFIC SIGNAL
121112025 ETHERNET SRV (DSPCH) #9€

2,229.00

890.67
30.00

Page: 1

Page 36

Page 37 of 179

apChklst

FinalGheck List
City of Sanger

0110912026 9:27:09AM

Bank : waap WESTAMERICA BANK

Gheck#
96346

(Continued)

Date Vendor

lnvoice

1t9t2026 08477

coMcAsToABLE 230483

Voucher:
96347
96348
96349
96350

96351

96352
96353
96354
96355

1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
119t2026

Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

96357
96358
96359

lnv Date Descriotion
12t3t2025

INTERNET CAM (501 ACAD) #

234428

12n/2025 INTERNET SRV.PD #81 55500,

5646

12t8t2025
1t2t2026

12962

coMcAST CABLE COMM| 001003227631

05241

CORELOGICSOLUTIONS

01611

COUNTY OF FRESNO, TR 383946

11727

CSG CONSULTANTS INC. 8251706

30824210

63857
F251317

CABLE SRV-PD #81 555001 60(
PHONE SERVICE - FD

Amount Paid

Check Total

278.19
257.98
28.64
572.88

564.81

572.88

llI3OI2O2SPROFESSIONALSERVICES

237.62

237.62

1212212025 AMB REGISTRATION

728.80

728.80

5,081.07
1,221.00
260.00
442,252.00

6,562.07
442,252.00

1211 12025 PROFESSIONAL

SERVICES
SERVICES
1211 12025 PROFESSIONAL SERVICES
12t19t2025 2025-26 3RD QTR |NVOTCE
121 1212025 PROFESSIONAL

11603

CSJVRMA

02324

CUMMINS SALESAND SE Y4-251236583 1212212025 E120 FUEL SENDER

1,916.24

1,916.24

00515

CURTIS&SONS, LN

1021372

2,174.50

2,174.50

08141

CVFCA

MEMBERSHIP 1012212025 CVFCA MEMBERSHIP

50.00

50.00

12162

DEFINITIVE STAFFING SC 16383
16341
16404
16425

INVO448

16362
96356

Page= 2

1211812025 THERMAL IMAGER

12t12t2025 TEMP LABOR SRV -PE 12I7I2I
11t28t2025 TEMP LABOR SRV- PE 111212(
12t19t2025 TEMP LABOR SRVS -PE 1211.
12t26t2025 TEMP LABOR SRVS - PE 1212
12t5t2025 TEMP LABOR SRVS -PE 11131
TEMP LABOR SRVS -PE 1212,
1t2t2026
T120 WATER TANK FILL SCRI
1t5t2026

4,1 93.1 0

35,913.15

445.40

445.40

100.00

100.00

12t3t2025 CAR RENTL (J. JOHNSON) #6

1,665.20

1,665.20

1211912025 OPEN PO - FINANCIAL SERVI

1,025.00

1,025.00

1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

11435

16441
DEROTIC EMERGENCY E NO-6598

12792

DON'S MINISTORAGE JAN

11112026 HR STORAGE

11324

ENTERPRISE FM TRUST 120325

1t912026

12941

ESJ SERVICES

2505

7,078.50
7.057.80
6,788.25
6,098.40
4,697.10

Voucher:

Page.2

Page 37

Page 38 of 179

apGhkLst
0110912026 9:27:09AM

FinalCheck List
City of Sanger

Bank: waap WESTAMERICA BANK

Gheck#
96360

96361

(Continued)

Date Vendor

lnvoice

119t2026 04821

FERGUSON ENTERPRISE OO5O7O3
6402459

Voucher:

1t9t2026
Voucher:
1t9t2026
Voucher:

12997

FLOCK GROUP

00299

INC

0050837
0050758
INV-78456

1t9t2026
Voucher:
1t9t2026
Voucher:

00318

FRESNO CITY COLLEGE 19712893
1 9694935
1 9501435
FRESNO COUNTY DEPT I P-6O74

10105

FRESNO COUNTY EDC

96365

1t9t2026
Voucher:

96366

1t912026

96362

96363
96364

96367
96368
96369

Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

Page: 3

Amount Paid

lnv Date Description
12t12t2025 R&M/ PARTS FOR BW LEAK
1211112025 CC KITCHEN SINK
12t15t2025 WELL 25
12t15t2025 R&M/ PARTS FOR BW LEAK
11t3t2025 LPR FLOCK CAMERASYSTEN
1211112025 REGIST. A. NELSON

121812025 REGIST. J. BOUST
911512025 REGIST. J. ACEVES-CRUZ
121512025 DISPATCHING SERVICES - DI
121 1 OI2O25 MEMBER

DU ES/QTR2

12253

HALICO GOLD LLC

Q22025-2026
Q32024-2025
Q42024-2025
sAN20251130

3I1OI2O25 MEMBER DUES/QTR3
512312025 MEMBER DUES/QTR4
11t30t2025 K-9 FOOD

08753

HARTFORD-PRIORITY AC 56459 1 1 37366

113112025 EE DISABILITY/ LIFE

0739

HOFFMAN SECURIry 753403

11071

IMSALLIANCE

1212212025 SERVICE CALL CHARGE
1212212025 SECU RITY SERVICES
11 121 12025 NAM ETAGS-PASSPO RT

06804

INDUSTRIAL ELECTRICAI. PI-O88O2O

1

752946
25-2823

INSURA

1112612025 R&M/ REPLACE BLOCK HEAT

Check Total

621.O2

293.63
130.02
124.21

22,400.00

1,168.88
22,400.00

105.00
84.00
61.00
1,533.50

250.00
1,533.50

1,421.81
1,421.81
1,421.81

4,265.43

443.42

443.42

3,798.41

3,798.41

150.00
65.00
204.72

215.00
204.72

1,796.13

1,796.13

Page:3

Page 38

Page 39 of 179

apGhkLst
0110912026 9:27:09AM

FinalGheck List
City of Sanger

Bank : waap WESTAMERICA BANK

Check#
96370

(Continued)

Date Vendor
1t9t2026 10972

lnvoice
JOHNSON,

JOSHUA PERDIEM

Voucher:

96371

96372
96373

96374
96375

1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

96376

119t2026

96377

Voucher:
1t9t2026
Voucher:

96378
96379
96380
96381

1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

Page: 4

PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM
PERDIEM

lnv Date Description
1t6t2026
1t6t2026
1t6t2026
1t6t2026
1t6t2026
1t6t2026
1t6t2026
1t6t2026
1t6t2026
1t6t2026

PERDTEM 3t7t26-3t8t26
PERDT EM 3t 1 4t26-3t 1 5t26

116t2026

PERDIEM 1119126

1t6t2026
12t5t2025

PERDIEM 2116126
PRE-EM PLOYEE PHYSICALS

PERDT EM 1 I 1 0t26-1 I 1't t2026
PERDT EM 1 I 17 t26-1 I 1 8t26

PERD| EM 1 t24t26-1 t25t26
PERDT EM 1 t31 t26-2t 1 t26
PERDTEM 2t7t26-2t8t26
PERDT EM 2t 1 4t26-2t 1 5t26
PERDT EM 2t21 t26-2t22t26
PERDT EM 2t28t26-3t 1 t26

11757

KINGS INDUSTRIAL OCCI 320243

11627

KOEFRAN INDUSTRIES II\ 0000690935 1113012025 ACO FREEZERS

02223

LANGUAGE LINE SERVIC 11784483

10019

LES SCHWAB

12029

LEXIS NEXIS COPLOGIC I 1030003279 11130/2025 ONLINE REPORTING SYST

00533

LIEBERT CASSIDY WHIT]\ 31 0931
310930
LIFEASSIST,
2032647

11 t30t2025 NEGOTTATTONS

2038522
2038524

1212612025 EMS SU PPLI ES
1212612025 EMS SUPPLI ES

00534

INC.

LIGHTHOUSE ELECTRICI 5D226

02614

LOZANO

SMTTH

2264591

2264590

10564

TRANSLATION SRV

TIRES 56400429756 12t24t2025 TTRES - UN|T #132 & 11

12706

02317

11 I3OI2O25

LYNN PEAVEY COMPANY 422993
423419
MAC GENERAL ENGINEEI 1

11 I3OI2O25 LEGAL SERVICES

121 1212025 EMS SUPPLIES

1211812025 XMAS DECOR/ BREHLER SQI

121912025 PROF LEGAL SRVS. NOV
121912025 PROF LEGAL SRVS - NOV
121812025 SUPPLIES
1213012025 LARG SHOE CVRS
12t24t2025 LOCAL STREET CtP 23-02

Amount Paid

Check Total

102.00
102.00
102.00

102.00
102.00
102.00
102.00
102.00
102.00
102.00
34.00
34.00
3,231.90

1,088.00
3,231.90

350.00

350.00

2.64

2.64

776.32

776.32

988.80

988.80

3,015.00
810.00
4,887.53
3,540.69
1,831.06
6,837.69
6,517.50
2,590.96
234.94
85.35
173,819.22

3,825.00

10,259.28
6,837.69

9,108.46
320.29
173,819.22

Page:4

Page 39

Page 40 of 179

apChklst

FinalCheck List
City of Sanger

0110912026 9:27:09AM
BanK : waap WESTAMERICA BANK

Check#
96382

(Continued)

Date Vendor
1t9t2026 06571
Voucher:

Page: 5

lnv Date Description

lnvoice
METRO UNIFORM & ACCI 303077

11t25t2025 UNrF SUPPLTES (PD)
11t25t2025 UNtF SUPPLTES (PD)
11t25t2025 UN|F SUPPLTES (PD)
1OI3I2O25 M. KAUR UNIFORM
11t25t2025 UNIF SUppLtES (S. BERNAL)
11t25t2025 UN|F SUppLtES (M. BURKDOT

Amount Paid

Check Total

1,224.19

96383

119t2026

11146

303089
303084
300973
303109
303104
MGT OF AMERICA CONST 65880

96384

Voucher:
1t9t2026
Voucher:

06909

MIGHTY MART INC

96385

119t2026

00596

MISSION LINEN SUPPLY DEC

96386

Voucher:
1t9t2026
Voucher:

08962

12436

MOORE TWINING ASSOC 00068278
2506496
2512774
MV TRANSPORTATION IN 10212025

11735

NAVIA BENEFIT SOLUTIO 11052937

1213012025 COBRACOVERAGE - DEC'25

200.00

200.00

03356

OFFICE DEPOT

11t21t2025 DRY ERASE BOARD
12t2t2025 OFFICE SUPPLIES
12t3t2025 OFFICE SUPPLIES
11t21t2025 OFFICE SUPPLIES
11t21t2025 OFFICE SUPPLIES
12t5t2025 OFFICE SUPPLIES
12t22t2025 GYM (DEC)

215.50
148.47
105.94
89.99
69.14
57.36
24.99

686.40
24.99

23,325.81
7,923.82
7,501.50
3,029.50
462.75

42,243.38

96387
96388
96389

1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

11302025

450047828001
447498478001
449363175001
44661 391 5001

96390
96391

1t9t2026
Voucher:
1t9t2026
Voucher:

12s97

OLSON, NATHAN

12830

OLSSON, INC

445012674001
447161452001
REIMB
546287
56041 0

549805

557182
562449

1,213.21
1 ,194.89

11t20t2025 SB-90 CLATMS FY26

145.58
76.05
76.05
1,300.00

3,929.97
1,300.00

11t30t2025 FUEL - PD

1,038.80

1,038.80

1213112025 DEC - PW UNIFORM/ LINEN S

1 ,639.10

1

1013112025 DOM & IND/ PERMIT SAMPLII

I3OI2O25 INDUSTRYS/ PERMIT SAMPLI
1211512025 INDUSTRYS / PERMIT SAMPL
1012112025 SENIOR CENTER - PUMPKIN

6,741.00
202.00
136.00
135.00

7

7t27t2025 PROVIDE TRAFFIC SIGNAL TI
11t24t2025 PROVIDE TRAFFIC SIGNAL TI
8t25t2025 PROVIDE TRAFFIC SIGNAL TI
10t26t2025 PROVIDE TRAFFIC SIGNAL TI
1211612025 PROVIDE TRAFFIC SIGNAL TI

,639.10

7,079.00
135.00

Page: 5

Page 40

Page 41 of 179

apchklst

FinalCheck List
City of Sanger

0110912026 9:27:09AM
BanK : waap WESTAMERIGA BANK

Gheck#
96392

(Continued)

Date Vendor
1t9t2026 08739

96394
96395

96396
96397
96398

'1t9t2026

Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

1t9t2026
Voucher:
1t9t2026
Voucher:
11912026

lnv Date Description

lnvoice
O'REILLYAUTO PARTS 2774-236493

Voucher:

96393

Page: 6

1211612025 BATTERY

Check Total

171.70
49.99
49.80
43.48
4,800.00

314.97
4,800.00

129.00

129.00

3,808.15
1,196.50
1,142.04
660.75
500.00

6,807.44
500.00

RS-13575 1211712025 LIDAR SERVICE

250.50

250.50

s144098999.001 12t10t2025 R&M / UNtTAp FOR AERATOR

295.45

295.45

2774-237477

12121 12025 WIPER BLADES

2774-237032
2774-237655
13022

PAYLESS TRANSMISSION 21 O9O

1211912025 DEF FOR SEWER TRUCK
12I23I2O25INSTALL REC TUBE FOR TRA
121 17 12025 TRANSMISSI ON ASSEBLY

12062

PEREZ, SILVESTRE REIMB

1211512025 CWEA RENEWAL FEE

10475

PMSI

10777

PRETZER FARMS & SER\ 684

07260

RADAR SHOP,

12513

REXEL USA INC

279393
279303
279406
279408

THE

Amount Paid

PELICI
121512025 BOYS & GIRLS CLUBA.C.
1211512025 CM-CITY HALL HVAC REPAIRI
12t16t2025 BOYS & GTRLS CLUBA.C.
111312026 ANNUAL EMPLOYEE PESTICI
121 11 12025 HVAC THERMOSTATS

Voucher:
96399

119t2026

12659

ROCKEEZ ENGINEERING 12488A

1213012025 MINOR EQUIP/ ELECTRICAL (

2,674.69

2,674.69

96400

Voucher:
1t9t2026
Voucher:

00433

SANGER CHAMBER OF C 6213

121 1912025 PROF SERVICES-JAN

119t2026

12634

SANGER GROCERY OUTI 1OO8

12t19t2025 TREK TO THE TREE (COUNC
12t17t2025 PET FOOD

6,666.67
595.00
899.38

7,261.67
899.38

09368

SEQUOIACOUNCIL

1212212025 REN EWAL K.ZARAGOZA

95.00

95.00

03709

SILVA'S OIL COMPANY IN( 479493
477072
STRYKER SALES CORP 9211183327

96401

96402
96403
96404

Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

6214

04287

1

535

1211612025 OIL: WELL MAINT

1,570.91

91812025 BLUE DEF DIESEL

238.00
4,665.39

1

2129 12025 G U RN EY MATTRESS/R ESTRI

1,808.91

4,665.39

Page:6

Page 41

Page 42 of 179

apchkLst

FinalGheck List
City of Sanger

0110912026 9:27:09AM

Bank : waap WESTAMERICA BANK

Check#
96405

(Continued)

Date Vendor
1t9t2026 10973

lnvoice
SUPERIOR POOL PRODU Q2033442

Voucher:

96406
96407
96408
96409
96410
96411

96412
96413

96414
96415
96416

1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:
1t9t2026
Voucher:

Page: 7

Amount Paid

lnv Date Descriotion

Check Total

12t8t2025 BULK CHLORINE - WELL 9
12t15t2025 BULK CHLORINE - WELL 25
12t5t2025 BULK CHLORINE - WELL 8
12t212025 BULK CHLORINE - WELL 2A
12t15t2025 BULK CHLORINE - WELL 7A
12t4t2025 CREDIT-BULK CHLORINE - W
12t9t2025 VEHIC MAINT'17 FORD EXPL

1,005.57
868.12
757.60
752.37
653.98
-16.59
1,990.74

4,021.05
1,990.74

9510883003 12t1t2025 10 DRTLL / 10 YEAR REPLACE

1,625.44

1,625.44

1,650.00

1,650.00

1211612025 OVERHEAD PAGING SYSTEM

59.66

59.66

Q2033491
Q2033434
Q2033398
Q2033490
08757

Q2033422
SWANSON FAHRNEY FOI 256367

11596

TELEFLEX LLC

12252

TELSTAR INSTRUMENTS 129957

08821

UN|TY

09239

UNLIMITED TECHNOLOG 82091

121112025 ALARM MONITOR. NOV

32.00

32.00

10j48

UNWIRED BROADBAND II 02578559

1213012025 BROADBAND YRD (JAN'26)

259.99

259.99

11840

VALLEY SHREDDING 216127

11 I3OI2O25 DOC SHREDDING

45.00

45.00

08709

VERIZONWIRELESS 6130957554

121 1 312025 TOUGH BOOK COMPUTERS

266.07

266.07

13019

VEZINA INDUSTRIES INC 104489

121 1212025 AN I MAL SH ELTER

9,500.00

9,500.00

01086

VIDEO INSPECTION SER\ 9993

1211812025 R&M / CLARIFIER MAINT
1211812025 R&M / CLARIFIER MAINT

3,600.00
1,050.00
9,413.40

4,650.00
9,413.40

tT

111925

9992
11213

WEST VALLEY CONSTRU 9

121 17 12025 SCADA REPORTI

12t4t2025 WELL 22

NG

Page: 7

Page 42

Page 43 of 179

apchklst

FinalCheck List
Gity of Sanger

0110912026 9:27:09AM

Bank : waap WESTAMERICA BANK

#
96418

Check

Date

Vendor

1t9t2026 00931
Voucher:

Page: 8

(Continued)

lnvoice
YAMABE & HORN ENGINE 54818
54821
54830
54837
54817

54826
54844
54843
54838

54845
54835
54850
54841
54819

54846
58414
54823
54847

54832
54842
54836
54827
54840

54834
54848
548'13

54854

54822
54815
54583

54825
54855
54833
54811

54828

Amount Paid

lnv Date Description
12t17t2025 TOMBSTONE WATER CONNE
12t17t2025 LOCAL STREET IMPR PROJ 2
12t17t2025 LOCAL STREETS IMPR CIP 2z
12t17t2025 TRACT 6493
12t17t2025 WELL 19
12t17t2025 SOMERSET SUBDIV
12t17t2025 CENTRALAVE RECONSTRUC
12t17t2025 BETHEL AVE REHAB-ANNADI
12t17t2025 VETS MEM PLMA P2
12t17t2025 CMAQ RESIDENTIAL PAVING
12t17t2025 AHSC I NFRASTRUCTURE IM[
12t17t2025 LOCAL STREETS IMPR CIP 2{
12t17t2025 SOMERSET SUBDIV PHASE 2
12t17t2025 WELL22
12t17t2025 GRNWD/JENSEN INTERSEC
12t17t2025 NORTH & GREENWOOD SWF
12t17t2025 ALMONDAVE REPONSTA(BE
I

12t17t2025 ACAD-JENSEN-GRNWD BI KE
12t17t2025 PITMAN FARMS HATCHERY
12t17t2025 SERENADE II SUBDIVISION
12t17t2025 JENSEN RECONSTRUCTION
1211712025 HSIP CYCLE 11 PROJECT
12t17t2025 SPR 2024-16 AUTRY PLUMBII
12t17t2025 SANGER LEAD & COPPER
12t17t2025 SPR 2025-08 TRACTOR SUPF
12t17t2025 TRACT 5826 - GREENWOOD
12t17t2025 LOCAL LIMIT STUDY
12t1712025 BETHEL AVE REHAB-CITY LIN
12t17t2025 TRACT 6327-GRNWD ESTATE
11t11t2025 ACADEMY & 7TH EV CHRG S'
12t17t2025 BETHEL & ALMOND TRAFFIC
12t17t2025 SANGER GENERAL GIS SRVS
12t17t2025 SPR 2024.08 SANGER FENCE
12t17t2025 SGMA IMPLEMENTATION
12t17t2025 SPR 2023-1 4-STORAGE STAT

Gheck Total

29,516.60
26,677.70
22,134.68
21,462.50
15,303.75
13,688.70
13,500.00
13,032.50
11,787.50

9,713.75
6,467.40
6,425.00
6,095.00
5,614.95
5,574.60
5,119.55
3,445.00
2,940.00
2,905.00
2,537.50
2,528.95
2,457.50
2,156.10
1,883.75
1,867.50
1,727.35
1,600.00
1,520.25
1,518.40
1,470.00
1,406.25
1,161.25
1,102.50
840.00
595.00

Page:8

Page 43

Page 44 of 179

apChkLst
0110912026 9:27:09AM
Bank
Check #

FinalCheck List
City of Sanger

waap WESTAMERICA BANK

Date Vendor

(Continued)

lnvoice

Inv Date Descriotion

54852

12t17t2025 ACADEMY & 7TH EV CHARGII
12t17t2025 2024 ENCROACHMENT PERI\J
12t17t2025 JENSEN & INDIANOLA TRAFF
12t17t2025 STANDARD PLAN UPDATES
12t17t2025 LOCAL STREETS IMPR PROJ
12t17t2025 JENSEN AVE DENTAL OFF
11t11t2025 TRACT 6504
12t17t2025 TRACT 6504
12t17t2025 2025 ENCROACHMENT PERIV
12t5t2025 TOI LET/HANDWASH (RANGE

54831

54824
54816
54829
54820
54579

54849
96419

1t9t2026 04596

Page: 9

ZWEIGLE SEPTIC SERVI( ;;33?

Amount Paid

Gheck Total

420.00
307.60
280.00
245.00
210.00
175.00
140.00
140.00
72.30
225.00

249,766.38
225.00

Voucher:

Sub total foTWESTAMERICA

BANK: 1,139,872.54

Page:9

Page 44

Page 45 of 179

apchklst
01r09t2026 9:27:09AM

88 checks in this report.

FinalCheck List
Gity of Sanger

Page: 10

Grand TotalAll

Checks: 1,139,872.54

Page: 10

Page 45

Page 46 of 179

apGhkLst
0111212026 2:22=O3PM
Bank
Check #
96420

FinalGheck List
Gity of Sanger

Page: 1

waap WESTAMERICA BANK

Date Vendor
1t12t2026 07711

lnvoice

lnv Date Description

Amount Paid

Check Total

82,400.00

82,400.00

CALGON CARBON CORP. 90214323

11t6t2025

GAC WELL 7A- CARBSORB 3

GARCIA, FERNANDO PERDIEM

1t12t2026

PER DtEM 1 t13t26-1 t15t26

149.00

149.00

1t12t2026

PER DtEM 1 t13t26-1 I 15t26

149.00

149.00

Sub total for WESTAMERICA BANK:

82,698.00

Voucher:
96421

1t1212026 10742
Voucher:

96422

1t12t2026 08151

GARZA,

RAMIRO

PERDIEM

Voucher:

Page: 1

Page 46

Page 47 of 179

apGhklst
0111212026 2:22:O3PM

3 checks in this report.

FinalGheck List
Gity of Sanger

Page: 2

Grand Total All Ghecks:

82,698.00

Page:2

Page 47

Page 48 of 179

apchklst

FinalCheck List
Gity of Sanger

01113//2026 8:49:40AM

Page: 1

Bank : waap WESTAMERICA BANK

Check#
96423

Date Vendor
1t13t2026 13023

lnvoice

lnv Date Descriotion

Amount Paid

Gheck Total

LIBERTY CHEVROLET VIN#162780 111212026 2026 CHEVROLET SILVERAD( 38,821.00

38,821.00

Sub total for WESTAMERICA BANK:

38,821.00

Voucher:

Page:1

Page 48

Page 49 of 179

apchkLst

0l,nU2026 8:49:40AM

I checks in this report.

FinalGheck List
City of Sanger

Page: 2

Grand TotalAll Checks:

38,821.00

Page:2

Page 49

Page 50 of 179

apChkLst

FinalCheck List
City of Sanger

0112612026 9:14:34AM

Page: I

Bank : waap WESTAMERICA BANK

Check#
96424

Date Vendor
1126t2026 04418

lnvoice

lnv Date Description

2417 PET VETS

95839

12t21t2025 VET CARE #171082

ACTION TOWNG DIVE

1

064

12t31t2025 VEHC EVID STOMGE
10t31t2025 VEHC EVID STORAGE
11t30t2025 VEHC EVID STORAGE
12t31t2025 ALARM MONITORING (YARD)
12131t2025 ALARM MONITORING (SYC)
1t6t2026
DRUG/ALCOHOL TESTING

Amount Paid

Check Total

257.40

257.40

Voucher:

96425

1126t2026 09470
Voucher:

1062

96426

1t26t2026 12806

ADS SECURITY

96427

Voucher:
112612026 11604
Voucher:

1063
013926
013927

ADVENTIST HEALTH

2705

1t26t2026 04482

ALEX FOOD MART &

SEPT
OCT-NOV

96428

Voucher:
96429
96430
96431

1t26t2026 04701
Voucher:
1t26t2026 07501
Voucher:

APACHE SMOG INC

1t26t2026 07501

AT&T MOBILIW

DEC
056505

9I3OI2O25 CAR WASHES (PD) SEPT
11t30t2025 CAR WASHES (pD) OCT-NOV
12t31t2025 CAR WASHES (PD) DEC

11512026 F-250 otl CHANGE
1t8t2026
12t8t2025

AT&T MOBILITY

287286160185
287286160185
287305911613

AT&T MOBILITY

831514171

CELL PHN CHRGS. PD
CELL PHN CHRGS - PD
CELL PHN CHRGS

1,207.50
1,162.00
1,125.00
150.00
105.00
1,158.00

3,494.50
255.00
1 ,1 58.00

468.00
378.00
198.00
151.18

1,044.00
151.18

4J80.76
4,030.03
799.82

8,210.79
799.82

1212712025 CELL PHN CHRGS

654.34

654.34

1t2t2026

Voucher:

96432

1t26t2026 07501
Voucher:

96433

1t26t2026 07501

AT&T MOBILIry

287288454255

111012026 CELL PHN CHRGS-FD

48f .87

487.87

96434

Voucher:
1t26t2026
Voucher:

AUTOZONE, INC

02862897342

11112026 WPER BLADES

42.38

42.38

B&M SUPPLIERS LLC

JRP-0113

121212025 NITRILE GLOVES

910.00

910.00

BERNAL, SADIE

REIMB

1t9r2026 GYM (DEC/JAN)

60.00

60.00

BLUETRITON BRANDS

0648930276838
0518730001059
06A8730276837

11612026 BOTTLED WATER

REIMB

11112026 FOOD FOR CRIME SCENE

150.30
140.26
96.68
102.64

387.24
102.64

96435

04311

1t26t2026 12694
Voucher:

96436

1t26t2026 13025
Voucher:

96437

1t26t2026 12877
Voucher:

96438

1126t2026 04721

BOUST, JASON

12t20t202s BOTTLED WATER (PD)

1r6t2026 BOTTLED WATER (FTNANCE)

Voucher:

Page: 1

Page 50

Page 51 of 179

apchkLst
0112612026 9:14:34AM

FinalGheck List
Gity of Sanger

Bank: waap WESTAMERICA BANK

Check#
96439
96440
96441

96442

1t26t2026 10678

lnvoice
MILAGE

111312026 MTLAGE 12t12t2s

1 1599

CANON FINANCIAL

42303684

00922

CHEVROLET BUICK GMC CVCS2O6O89

1t26t2026 09872
1t26t2026 08477

1211212025 COPIER LEASES & USAGE

1,640.40

1,640.40

5646
CONSERVATION TECHNIX 1258
1265
coRELOGtC SOLUTTONS 30827356

12t30t2025 VEHIC MAINT'17 CHEVY
12t3'v2025 VEHIC MAINT '19 CHEVY
12t15t2025 ETHERNET SRVS (501 ACAD)
1t1t2026
ETHERNET SRV (DSPCH)
12118t2025 INTERNET SRV-FINANCE
1t3t2026
INTERNET CAM (501 ACAD)
1ni2026
INTERNET SRV.PD
1t8r2026
CABLE SRV-PD
12t2t2025 PROFESSIONAL SERVICES
1t2t2026
PROFESSIONAL SERVICES
12t31t2025 COMPUTER SOFTWARE

3,340.64
1,009.78
770.60
758.16
565.65
278.19
257.98
56.80
12,170.90
3,062.76
336.35

15,233.66
336.35

CRISCOM COMPANY, THE 271656

111512026 GRANT WRITING SVCS FOR

7,000.00

7,000.00

PROFESSIONAL SERVICES
PROFESSIONAL SERVICES
RECREATION SOFTWARE

7,241.39
943.50
5,000.04

8,184.89
5,000.04

coMcAsT
coMcAsT CABLE

cvcs206748
258822612
259286585
215',t87

234428

Voucher:

96445

1t26t2026 05241

96446

Voucher:
1t26t2026
Voucher:

96447

11262

1t26t2026 11727

CSG CONSULTANTS INC.

1t26t2026 12975

8251 868

1t5t2026

64276

4,350.42
1,528.76

1,158.62

DASH PLATFORM LLC

tNVo1543576

1t7t2026
10t6t2025

DELRAY TIRE &

5001 6551 9

12t19t2025 TTRES-PD VEH#SI 1 6

513.99

5'13.99

DOLAN, HAYDEN

REIMB

111512026 DOLAN- SYMPOSIUM

225.00

225.00

EAGLESHIELD PEST

221874

811912025 PEST CONTROL SERVICES

546.00

546.00

ENTERPRISE FM TRUST

010626

11612026 CAR RENTL (J. JOHNSON)

2,083.28

2,083.28

FEDERAL EXPRESS

9-1 09-57314

1211912025 DELIVERY SRV-PD

123.78

123.78

FIRE APPARATUS

0205\ /20697

11512026 E12O FUEL ISSUES

776.37

776.37

Voucher:
96448

Check Total
84.28

230483

1t26t2026 12912

Amount Paid
84.28

Voucher:

96444

lnv Date Description

CAMARENA, KARLA

Voucher:

96443

(Continued)

Date Vendor
Voucher:
1t26t2026
Voucher:
1t26t2026
Voucher:

Page: 2

Voucher:
96449

1t26t2026 02798
Voucher:

96450

1t26t2026 12661
Voucher:

96451

1t26t2026 12559
Voucher:

96452
96453
96454

1t26t2026 11324
Voucher:
1t26t2026 00300
Voucher:
1t26t2026 09586
Voucher:

Page:2

Page 51

Page 52 of 179

apChkLst

FinalCheck List
City of Sanger

0112612026 9:14:34AM
Bank
Check #
96455

wAapWESTAMERICA BANK

(Continued)

Date Vendor
1t26t2026 10423

Page: 3

Amount Paid

lnvoice

lnv Date

FLEETZOOM

F211225

11612026 SVCS/NORTH & GRNWOOD

Description

Check Total

360.00

360.00

1,128.85

1,128.85

Voucher:
96456

1t26t2026 08816

FOREMOST

741995

1OI7I2O25 CRIME PREV SUPPLIES

96457

Voucher:
1t26t2026
Voucher:

FRESNO COUNTY

so23294

113112026 DISPATCHING SERVICES FY

40,581.68

so23242

12131 12025 DISPATCHING

FRESNO OXYGEN, INC.

009173541 1

12t31t2025 AQUATTCS CO2

39,271.93
32.32

79,853.61
32.32

FRESNO TRUCK CENTER

R001230802:01

1t15t2026

4359 PREVENTATIVE MAINT

1,876.17

1,876.17

FRONTIER

JAN

1t31t2025

TELEPHONE SRV

5,593.31

5,593.31

96458

04867

1t26t2026 00331

SERVICES FY

Voucher:
96459

1126t2026

07174

Voucher:
96460

1t26t2026 10345
Voucher:

96461

1t26t2026

1

3029

GIERLICH-MITCHELL, INC 16916

12t11t2025 MINOR EQUIP

3,085.44

3,085.44

HALICO GOLD LLC

sAN20251231

1t30t2026

SUPPLIES (K9)

279.98

279.98

PER D|EM 2t24t26-2t27 t26

675.00

675.00

Voucher:

96462

1t26t2026 12253
Voucher:

96463

1t26t2026 12994

HARMON, VIRGINIA

PER DIEM

1t21t2026

96464

Voucher:
1t26t2026
Voucher:

12424

HOULE, BAILEY

REIMB

12t15t2025 STATE FIRE TRAINING CERT

100.00

100.00

1t26t2026

01 933

IAFC MEMBERSHIP

000293880

12t31t2025 IAFC ANNUAL MEMBERSHIP

285.00

285.00

10651

IAPE

M26-C426675

1t11t2026

CSO KIM JONES

65.00

65.00

INNOVATIVE

4

1t7t2026

CESAR CHAVEZ PARK

132,213.88

132,213.88

96465

Voucher:
96466

1126t2026

Voucher:
96467

1t26t2026 12801
Voucher:

96468

1t26t2026 09085

INTERWEST

2924657

12t31t2025 PROFESSIONAL SERVICES

130.00

130.00

96469

Voucher:
1t26t2026
Voucher:

00445

JACK'S REFRIGERATION,

80151

9t29t2025

WATER DIVA.C.

1,321.50

1,321.50

1t26t2026 13024

JONES CONSTRUCTION

2822

11t12t2025 TOMBSTONE PROJ. - TANK

650.40

650.40

KOEFRAN INDUSTRIES

0000696001

12t31t2025 ACO FREEZERS

350.00

350.00

96470

Voucher:
96471

1t26t2026 11627
Voucher:

Page: 3

Page 52

Page 53 of 179

apchkLst
0112612026 9:14:34AM
Bank
Gheck #
96472

FinalCheck List
City of Sanger
(Continued)

waap WESTAMERICA BANK

Date Vendor
1126t2026

lnvoice

T|RE

1126t2026

56400431525 1t12t2026 NEWTTRES (4\'23 NTSSAN
56400431092 1t8t2026 NEWTTRES'25 FORD UN|T

LES SCHWAB

09489

LESLIE'S POOLMART INC 00166-01-09169 11212026 PLANT CHEMICALS

wPR9099427-00 8t18t2025 AQUATTCS - COUNry

Voucher:

96474

Inv Date Description

10019

Voucher:
96473

Page: 4

1t26t2026 12029

LEXIS NEXIS COPLOGIC 1030003534 1213112025 ONLINE REPORTING SYST

Amount Paid

Check Total

1,075.18
760.11
427.17
210.03
988.80

1,835.29
637.20
988.80

Voucher:

96475

1t26t2026 02317

LYNN PEAVEY COMPANY 423805

111512026 HEAT SEAL

67.41

67.41

MARTINEZ, LINA

PER DIEM

1t16t2026 PER DIEM 2t5t26-2t6t26

219.05

219.05

MCWLLIAMS, SOFIA

REIMB

111012026 MCWLLIAMS. SYMPOSIUM

875.00

875.00

METRO UNIFORM &

303482
303839
303812
303908

12312025

1,065.29
483.77
483.77
93.45
274,163.47
272,693.45
2,360.70

2,126.28

3392743

12t8t2025 UNIF SUPPLIES (PD)
12t16t2025 J. ALONSO BOOTS
12t16t2025 M. FRIES BOOTS
12t1812025 UNIF SUPPLIES (PD)
12t31t2025 DISPOSAL SRVS - DEC 2025
11t30t2025 DISPOSAL SRVS - NOV 2025
12t31t2025 FUEL. PD

546,856.92
2,360.70

720997

1t8t2026 PUBLTC NOTTCE- PH

720745

12t18t2025 PUBLTC NOTTCE - TRACT 6531
1t21t2026 PER D|EM 2t22t26-2t26t26

960.00
729.00
207.00

1,689.00
207.00

1,062.00
60.00
75.00

Voucher:
96476

1t26t2026 12956
Voucher:

96477

1t26t2026 12550
Voucher:

96478

1t26t2026 06571
Voucher:

96479

1t26t2026 09920

MID VALLEY DISPOSAL

96480

Voucher:
1t26t2026
Voucher:

MIGHTY MART INC.

96481

1t26t2026 0081 1

33801 73

06909

MINERAL KING

Voucher:

96482

1t26t2026 11795

MIRELES, MARIA NATALI

PERDIEM

MOORE TWNING

25'13290
2513291

Voucher:
96483

1t26t2026 08962
Voucher:

96484

1t26t2026 12164

MUNOZ, BERTHA

2512932

12t24t2025 \MA/TP/P ERM IT SAM PLI NG
12t24t2025 INDUSTRYS / PERMIT
12t17t2025 INDUSTRYS / PERMIT

2600046

1t2t2026

2513292
2600278
2512942

12t24t2025 INDUSTRYS / PERMIT
\AAA'TP/ PERMIT SAMPLING
1t8t2026
12t18t2025 \MA/TP/PERM IT SAM PLI NG
1t16t2026 GYM (DEC'2s-JAN'26)

220.00
202.00
202.00
202.00
108.00
108.00
20.00
60.00

121912025 SENIOR CENTER FIELD TRIP

75.00

REIMB

INDUSTRYS / PERMIT

Voucher:
96485

1t26t2026 12436

MV TRANSPORTATION 11252025

Voucher:

Page:4

Page 53

Page 54 of 179

apGhklst
0112612026 9:14:34AM

FinalGheck List
City of Sanger

Bank: waap WESTAMERTCA BANK
Check #
96486

(Continued)

Date Vendor
1t26t2026 07909

Page: 5

lnvoice

lnv Date Description

Amount Paid

NFPA

2757329

1211912025 NFPA ANNUAL MEMBERSHIP

225.00

OFFICE DEPOT

12130t2025 OFFICE SUPPLIES
1t5t2026
SUPPLIES (PD)
12t15t2025 OFFICE SUPPLIES
12119t2025 SUPPLIES (PD)
12t31t2025 OFFICE SUPPLIES
1211712025 OFFICE SUPPLIES - REC
1t8t2026
SUPPLIES (PD)
12t18t2025 OFFICE SUPPLIES. REC
1120t2026
PER Dt EM 2t 1 1 t26-2t 13t26

478.37
244.27
136.27
100.07

OLSON, NATHAN

450482844001
453517566001
452125273001
453090605001
45345301 3001
450741704001
4521 83885001
450716044001
PERDIEM

O'REILLYAUTO PARTS

2774-239627

11512026 BATTERY FOR PARKS

2774-236795
2774-239600
2774-238854

1211812025 BATTERY FOR PREVENTION
11512026 MOTOR OIL FOR VEHICLES
1213112025 WPER BLADES
111312026 WPER FLUID AC TRUCK
1 t21 t2026 PER DIEM 2t22t26-2t26t26

Check Total
225.00

Voucher:
96487

'U26t2026 03356
Voucher:

96488
96489

96490

112612026 12597
Voucher:
1t26t2026 08739
Voucher:

1t26t2026 06199

PITTS, CRAIG

2774-241241
PERDIEM

PMSI

279453

PROFESSIONAL PRINT &

279461
128191

86.91

49.24
46.41

15.96
458.15

1,157.50
458.15

195.16
188.62
84.68
82.61

5.64
207.00

556.71

207.00

Voucher:
96491

1t26t2026 10475
Voucher:

96492

1t26t2026 03989
Voucher:

96493

1t26t2026 09429

1t2t2026
1t5t2026
111512026

128176

1t20t2026

128251
128249

1fi9t2026

CITY YARD OFFICE HVAC
CITY HALL PW HVAC REPAIR
INSD SNGR INSERTS
UTILIry BILLING SRVS - DEC
UB LATE NOTICES (JAN)
UB SHUT OFF NOTICES - JAN

128248

1t19t2026
1t9t2026

QUADIENT INC

6251 1 903

1t1t2026

REYES, ROSA

DEC

1212312025 ZUMBA INSTRUCTOR

INSERTS (SHUT OFF) - JAN
POSTAGE METER RENTAL

712.00
507.00
2,106.04
1,283.74
941.35
407.52
253.37
173.38

4,992.02
173.38

205.80

205.80

2,270.00

2,270.00

1,219.00

Voucher:
96494

1t2612026 10823
Voucher:

96495

1t26t2026 126s9

ROCKEEZ ENGINEERING'12-492A

1213012025 R&M/ SLUDGE BED PIPING

Voucher:

Page:5

Page 54

Page 55 of 179

apchklst

FinalGheck List
Gity of Sanger

0112612026 9:14:34AM

Bank: waap WESTAMERTCA BANK

Check#
96496

(Continued)

Date Vendor
112612026 04766
Voucher:

Page: 6

lnvoice
SANCHEZ AUTO REPAIR

1570
1574
1577

Inv Date

Description

Amount Paid
39.75
39.75
39.75
39.75
39.75
39.75
39.75
39.75
39.75
39.75
39.75
39.75
6,666.67

477.00
6,666.67

500.17

500.17

Gheck Total

96497

1t26t2026 00433

SANGER CHAMBER OF

1552
6214

11t24t2025 SMOG INSPECTION
11t25t2025 SMOG INSPECTION
11t25t2025 SMOG INSPECTION
11t26t2025 SMOG INSPECTION
12t1t2025 SMOG INSPECTION
12t2t2025 SMOG INSPECTION
12t8t2025 SMOG INSPECTION
1112t2026
SMOG INSPECTION
11t19t2025 SMOG INSPECTION
1112012025 SMOG INSPECTION
11t20t2025 SMOG INSPECTION
11t20t2025 SMOG INSPECTION
1t21t2026 PROF SERVICES-FEB

96498

Voucher:
'U26t2026
Voucher:

SANGER GROCERY

1

009

1t7t2026 PET FOOD

SCA OF CA, LLC

2025-117000 11t30t2025 pWST SWEEP|NG - NOV

8,064.00

8,064.00

SANADM (JUL 25)
SANADM (NOV 25)
VEHIC MAINT'23 NISSAN

903.50
865.50
429.98

1,769.00
429.98

100.00

100.00

1,278.00

1,278.00

30.00

30.00

897.76

897.76

5,290.54

5,290.54

378.00
295.00
166.00

839.00

1

581

1590

1602
1624
1838
1546
1560
1557

96499

't2634

1t26t2026 03531
Voucher:

96500

1t26t2026 09567

SELF HELP

SANADMOT25
SANADM1125

96501

Voucher:
1t26t2026
Voucher:

SELMA NISSAN

N1cs339106

8t7t2025
12t9t2025
12t4t2025

SEQUOIA COUNCIL

1537

1t12t2026 2026 CHARTER FEE

09507

sEsAc rNc

747443

12t31t2026 MUSTC LIC FEE

3026

SHUFFORD, STACY

6260

1213012025 YBB 14U PA|D 10.18.25

SITEONE LANDSCAPE

161714887-001 1t7t2026 HERBTCTDE LLMD

SORELLISTAFFING

4

11912026 TEMP LABOR SRVS PE

SOUTH CO VETERINARY

DGT-3797
DGT-3773
DGT-3696

1t8t2026

EUTHANASIA

1n/2026

EUTHANASIA

1t2t2026

EUTHANASIA

96502
96503
96504
96505
96506
96507

13028

1t26t2026 09368
Voucher:
1t26t2026
Voucher:
1t26t2026
Voucher:

1

1t26t2026 09290
Voucher:
1t26t2026 13021
Voucher:
1t26t2026 07309
Voucher:

Page:6

Page 55

Page 56 of 179

apchkLst
0112612026 9:14:34AM
Bank
Gheck #
96508
96509
96510
9651 1

FinalGheck List
City of Sanger

waap WESTAMERICA BANK

(Continued)

Date Vendor
1t26t2026 11796
Voucher:
1t26t2026 08757
Voucher:
1t26r2026 05015
Voucher:
1t26t2026 12167
Voucher:

lnvoice

2,799.30

SWANSON FAHRNEY

256709
256824

1ni2026

1,444.91
94.10
175.00

1,539.01

VEHIC MAINT'25 FORD
VEHIC MAINT'25 FORD 5141
PER DtEM 5t5t26-5t8t26

TARASCOU, GREG

PERDIEM

1t5t2026
1t16t2026

TARGET SOLUTIONS

tNV134617

211212026 MEMBERSHIP

2,400.00

2,400.00

1

301 31

11612026 R&M/ BLOWER BLDG NORTH

9,480.10

9,480.10

11812026 ONLINETRAINING

1,467.06

1,467.06

179.45
144.65
116.25
90.00

440.35
90.00

96513

THE BRIEFING ROOM LLC 1498

TMNS UNION RISK &

175.00

TREVINO, CYNTHIA

62151-202511-1 12t1t2025
62151-202510-1 11tlt2025
62151-202512-1 1t1t2026
REIMB
1t9t2026

TREVINO, SANDRA

PERDIEM

1t16t2026 PER D|EM 5t5t26-5t8t26

449.05

449.05

TRI-SIGNAL

c168654

1113012025 FIRE ALARM SVS (SYC)

1,430.00

1,430.00

TYLER TECHNOLOGIES

045-549629

2561 8661 3-001

12t31t2025 TYLER TECHONOLOGIES :
12t10t2025 TYLER TECHONOLOGIES :
1211812025 TYLER TECHONOLOGIES :
12t23t2025 TYLER TECHONOLOGIES :
12t2t2025 W RI NG/LIGHTS/BOARDS/PAI

7,700.00
1,400.00
1,400.00
700.00
2,762.04

11,200.00
2,762.04

111984

1t5t2026 rT SRVS - DEC

1 1 1986

11512026 oFF|CE 365 - DEC
11512026 FIREWALL. DEC

6,317.18
1,919.67
384.49
239.76
21.44
32.00

8,882.54
32.00

Voucher:

1t26t2026 10180

Check Totat

2,799.30

TELSTAR INSTRUMENTS

96515

Amount Paid

1213012025 UTILIry/ PROPANE

1t26t2026 12252

1t26t2026 09880

Description

16170547079

Voucher:
1t26t2026
Voucher:

96514

lnv Date

SUBURBAN PROPANE

96512

12770

Page: 7

INVESTIGATIVE ACCESS
INVESTIGATIVE ACCESS
INVESTIGATIVE ACCESS
GYM (OCT/NOV/DEC)

Voucher:
96516

1t26t2026 10592
Voucher:

96517

1t26t2026 08547
Voucher:

96518

1t26t2026 04091
Voucher:

045-547603
045-548324
045548937

96519

1126t2026 04365

UNITED RENTALS

Voucher:
96520

1t26t2026 08821

UNITY IT

Voucher:

111985

111924
112053
96521

1t26t2026 09239

UNLIMITED

82128

1211612025 SSL RENEWAL
11512026 OVERHEAD PAGING SYSTEM
11112026 ALARM MONITOR - DEC

Voucher:

Page:7

Page 56

Page 57 of 179

apchklst

FinalGheck List
Gity of Sanger

0112612026 9:{4:34AM
Bank : waap WESTAMERTCA BANK

Gheck#
96522

(Continued)

Date Vendor
1t26t2026 10448

lnvoice

UNWREDBROADBAND INVO26O9199

Voucher:
96523

1t26t2026 09303

US

Page: 8

BANK

lnv Date Description

1t30t2026 BROADBAND YRD (FEB)

1126t2026

12674

1t26t2026 11840
Voucher:

96526

1t26t2026 01086

1t26t2026 13027

259.99
29,368.19

29,368.19

7870662

WATER EDUCATION FOR 2025-143

8t25t2025 BOND ADMIN FEES 25-26
7t25t2A25 BOND ADMIN FEES 25-26
12t31t2025 DOC SHREDDING
12t31t2025 DOC SHREDDING
12t18t2025 R&M/ COLLECTION SYSTEM
1211712025 R&M/ALLEY COLLECTION
12t31t2025 R&M/ SSB 2 3W LEAK ON
12t15t2025 FELLOWSHIP - COUNCIL MBR

3,025.00
2,500.00
135.00
45.00
5,250.00
2,825.00
2,220.75
3,500.00

10,295.75
3,500.00

XYLEMWATER

1211112025 DIFFUSER FOR AERATION

32,264.44

32,264.44

30.00

30.00

350.00
225.00
125.00
195,547.19

700.00
195,547.19

us BANK

7831 91 0

VALLEY SHREDDING 216512
216499
VIDEO INSPECTION 9991

Voucher:
96527

259.99

1211512025 CAL CARD PMT

Voucher:
96525

Check Total

6244

Voucher:

96524

Amount Paid

9986
1 0005

5,525.00
180.00

Voucher:
96528

1t26t2026 13012

3556E02871

Voucher:
96529

1t26t2026 12619

YBARRA, STEPHANIE 6272

1213012025 YBARRA-YBB 7U PAID

ZWEIGLE SEPTIC

912712025 TOILET RENTAL/ NATIONAL

Voucher:
96530

1t26t2026 04596
Voucher:

1232026

1t23t2026 02737

41378
42125
42109

PACIFIC GAS & ELECTRIC DEC

1t2t2026 TOTLET/HANDWASH (RANGE)
1212412025 R&M/ PORT-O-POTry MAINT
1213112025 GAS & ELECTRIC SRV

Voucher:

SubtotalforWESTAMER|CA BANK: 1,212,484.80

Page: 8

Page 57

Page 58 of 179

apChklst
0112612026 9:14:34AM

108 checks in this report.

FinalCheck List
Gity of Sanger

Page: 9

Grand TotalAllGhecks:

1,212,484.80

Page: 9

Page 58

Page 59 of 179

apchklst

FinalGheck List
Gity of Sanger

0112912026 9:55:58AM

Page:1

Bank : waap WESTAMERICA BANK
Check
96531

96532
96533
96534

#

Date Vendor
1t29t2026
Voucher:
1t29t2026
Voucher:
1t29t2026
Voucher:
1t29t2026
Voucher:

lnvoice

lnv Date Descriotion

Amount Paid

Check Total

001 75

ACADEMYHARDWARE DEC

12131 12025 HARDWARE/JAN ITORIAL SU F

1,728.35

1,728.35

08352

CA BLDG STANDARDS C( SB1473 ATR 4

1t23t2026 SB1473 ATR 4 2025

1,238.50

1,238.50

00243

DEPARTMENT OF CONSE SMIP QTR 4

1t23t2026 SM|P QTR 42025

3,968.74

3,968.74

03709

SILVA'S OIL COMPANY IN( NOV

11t30t2025 GASOLTNE

13,550.12

13,550.12

Sub total for WESTAMERICA BANK:

20,485.71

Page: 1

Page 59

Page 60 of 179

apchklst
0112912026 9:55:58AM

4 checks in this report.

FinalGheck List
Gity of Sanger

Page: 2

Grand TotalAll Ghecks:

20,485.71

Page:2

Page 60

Page 61 of 179

E-4
City of Sanger Fire Department
Greg Tarascou, Fire Chief

1700 7th Street • Sanger, CA 93657 • Phone (559) 875-6568 • Fax (559) 875-6611
February 12, 2026
To:

Honorable Mayor and Council Members
Nathan Olson, City Manager

From: Greg Tarascou, Fire Chief
RE:

FIRE DEPARTMENT REPORT FOR JANUARY

For the month of January there were 288 calls for services for ambulance services within our area and within
surrounding areas. Crews were also dispatched to 544 requests for services in January for fire calls, including
house fires, trash and warming fires, building fires, vehicle fires and unintentional or false alarm calls. This
total equates to 332 calls in January, or just over 10 calls per day.
Chute times are measured from the time the station is notified of an alarm to the time the unit goes enroute.
For the month of January our chute time was 77 seconds, just below our benchmark of 90 seconds.
Approximately 25% of the time our chute time was measured at less than 45 seconds. Our travel time is
measured from the time the unit is enroute to the time that we arrive on scene. For January our median
response time was 6 minutes, 44 seconds within the City. This is just over our benchmark of under 6 minutes
within the City. Our total call time for the month of January for EMS calls was measured at one hour, 5
minutes per call.
The Fire Department continued our recruitment efforts with our vacancies at single-role Paramedic and
Firefighter. In January we opened the recruitment for Paramedic and moved one of our Non-Safety EMTs into
a vacant Firefighter spot. We started the internal fire academy at the beginning of February and hope to finish
by the beginning of March. In addition, we will be interviewing and testing for the vacant Paramedic spots in
February with the hope of hiring by the end of May. Aside from the vacancies at the Non-Safety role, we are
fully staffed on the suppression side.
Administratively our staff have started working on end-of-the-year reporting requirements and are looking
forward to making mid-year adjustments. In addition, we started our State required inspections of our local
schools and multi-family dwellings. We continued our education into the new Federal reporting system called
NERIS and will look to start implementing other State-mandated programs into the Fire Department, including
a system that tracks personnel qualifications and Fire Department resources at a State level.
I am always available if you have any questions.

Page 61

Page 62 of 179

E-5
SANGER POLICE DEPARTMENT
Monthly Report
January 2026
John Reynolds
Chief of Police

Summary:
Self-initiated activity increased this month by 11% in response to several serious firearm / gang
related incidents, reflecting a proactive posture. These efforts resulted in arrests and the
recovery of evidence, with follow-up investigations ongoing. Traffic collisions remained
consistent, with no fatal or DUI related collisions reported.
Calls for Service:
Call Type
Total Calls
SelfInitiated

Current
Month
2594
1074

Previous
Month
2564
964

% Change
1%
11.4%

Crime Statistics:
Crime Type

Current Month

Homicide
Assault
Robberies
Burglaries

0
7
0
4

Previous Month %
Change
0
0%
7
0%
0
0%
2
100%

Traffic Collisions:
Collision Type

Current Month

Previous Month

Year to Date

Non-Injury
Injury
Fatal
DUI Related

8
4
0
0

8
4
0
0

8
4
0
0

Percentage
Change
0%
0%
0%
0%

1
Page 62

Page 63 of 179

Arrest and Citations:
Category
Felony Arrests
Misdemeanor
Arrests
DUI Arrests
Traffic Citations

Count
23
19
3
73

Notable Incidents:
December 31. 2025-January 1, 2026
Officers responded to the 600 block of I St regarding an assault with a deadly weapon with
gunshots fired. Upon arrival, officers located a male victim with gunshot wounds. The male
victim was transported to Community Regional Medical Center for his injuries while officers
and detectives searched the scene, collected evidence and interviewed numerous
uncooperative persons. Three firearms were located during the investigation and detectives
are conducting follow-up investigation.
January 4, 2026
Officers responded to multiple callers reporting shots fired around J St. and Edgar St. Officer
determined that a late model white PT Cruiser with heavy set male fired ten (10) shots in the
parking lot of 1410 J. St toward 3 adults and one juvenile before leaving the area.
Investigative leads were developed quickly, and detectives are conducting follow up
investigations.
January 14, 2026
Officers were dispatched to the 1600 block of J St. regarding a brandishing of a firearm by
suspect in a black Nissan. Officers spotted the vehicle, conducted a traffic stop and detained
all the occupants. A replica firearm resembling a Glock handgun was located and suspect was
arrested.
January 17, 2025
Officers were dispatched to the area of Jensen and Bethel for a report of possible shots fired.
Further information revealed that the brandishing of a firearm occurred at the Laundry Mat next
to Grocery Outlet. The suspect had left the immediate area and was contacted by officers in
the Walmart parking lot. He was found to be in possession of a replica firearm and had multiple
warrants for his arrest. He was arrested, booked, and cited out.
January 23, 2026
Officers with the Sanger Police Department along with the Multi-Agency Gang Enforcement
Consortium (MAGEC) served multiple search warrants throughout the city as a follow up to a
gang related shooting that occurred in the 400 block of K St. in the evening hours of January
18th. Four juvenile gang members were arrested, and evidence connected to the shooting was
recovered.

2
Page 63

Page 64 of 179

January 25, 2026
Officers were dispatched to the 200 block of Academy Ave. for a report of a shots fired
disturbance. While responding, another call was received regarding a stabbing in the 900
block of Sterling, and a short time later, the victim of a stabbing had been dropped off at the
Sanger Fire Department. The disturbance was determined to be gang related. The victim was
transported to the Community Regional Medical Center with non-life-threatening injuries.
Detectives working with the Multi-Agency Gang Enforcement Consortium have been
conducting follow-up investigations. The incident drew media attention and involved Academy
Ave. being shut down while evidence was searched for, located, and collected.
Personnel and Staffing:

Officers Marissa Burkdoll and John Ayers successfully completed field training and
began solo patrol duties.
Current recruitments are active for Police Officer and Police Cadet Positions with four
police officer vacancies.

3
Page 64

Page 65 of 179

For the Meeting of: February 19, 2026
Agenda Item No.: E-6

CITY OF SANGER

REPORT TO THE CITY COUNCIL
To:

Mayor and City Council Members

From:

Nathan Olson, City Manager

Subject:

Receipt of Update on Emergency Repairs at Wastewater Treatment Plant
Pursuant to Resolution No. 2026-04 and Request to Continue Declaration of
Emergency

Attachments:

1. Resolution No. 2026-04 and Resolution No. 2026-11

CONFLICT OF INTEREST:
None known.
RECOMMENDATION:
Staff recommend that the City Council adopt Resolution 2026-11, Continuing the Declaration of
Emergency in connection with Emergency Repairs at the Domestic/Industrial Treatment Facilities under
Resolution 2026-04.
EXECUTIVE SUMMARY:
The purpose of this staff report is to provide an updated status on the emergency repairs initiated under the
Determination of Emergency to address the Sanger Domestic/Industrial Wastewater Treatment Facility
(WWTF). This report summarizes the progress made, challenges encountered, and financial implications
of the ongoing repair efforts. Based on the status and projected needs, it is recommended to continue with
emergency actions under Resolution No. 2026-04 to ensure timely and effective completion of the repairs.
Reports on actions taken and status of the emergency will continue to be made at each regular meeting of
the City Council.

Prepared by:

Raymond Martin____

REVIEW: City Manager: ______
TYPE OF ITEM:

_X__
____
_X__
____
____

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Approved by: _____________________
Finance: _______

City Attorney: ______

COUNCIL ACTION:  APPROVED  DENIED  NO ACTION

____
____
____
____

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 65

Page 66 of 179

BACKGROUND:





July 18, 2024: City Manager Nathan Olson (as the Director of Emergency Services) declared an emergency
at the Sanger Domestic/Industrial Wastewater Treatment Facility, requiring emergency repairs. Immediate
emergency repairs were identified for the WWTF Digester, the Industrial/Domestic Headworks, and WWTF
Bypass Pump. Reference Resolution 2024-48.
August 2024: Repairs commenced, starting with the cleaning of the Digester, followed by work on the
Industrial Headworks. The Digester was cleaned out, and its valves were replaced.
November 21, 2024: City Council reviewed and ratified agreements with Rockeez and VIS for work on the
Industrial Headworks and cross-contamination emergency repairs. A new bypass pump was installed during
this time to correct cross-contamination issues after the thickening clarifier.
December 2024: Repairs on the Industrial Headworks were completed, including epoxy coating, installation
of a new line, concrete pit repairs, and valve replacements. Work immediately began on the Domestic
Headworks.
Early 2025: Domestic Headworks received attention due to debris buildup caused by a malfunctioning Bar
Screen. The Bar Screen was under warranty; parts were ordered and fixed.
January 16, 2025: City Council renewed the proclamation of emergency to address additional contracts
required for completing emergency repairs. This renewal emphasized the necessity for continued immediate
repairs without formal competitive requirements. Reference Resolution 2025-03.
March 20, 2025: City Council reviewed and ratified the agreement with Rockeez for Domestic Headworks
repairs. Work began on the Primary Effluent Pump Chambers related to the clarifiers.
April 17, 2025: City Council renewed the proclamation of emergency to address additional contracts required
for completing emergency repairs. This renewal emphasized the necessity for continued immediate repairs
without formal competitive requirements. Reference Resolution 2025-28.
April 17, 2025: Work on the Primary Effluent Pump Chambers was completed in early April. City Council
reviewed and ratified the agreement with Rockeez for the Primary Effluent Pump Chambers. Reference
Resolution 2025-29.
May 15, 2025: City Council renewed the proclamation of emergency to address additional contracts required
for completing emergency repairs. This renewal emphasized the necessity for continued immediate repairs
without formal competitive requirements. Reference Resolution 2025-35.
May 2025: Clarifiers are being prepped for their extensive rehab and epoxy coatings. Distribution box #7
was rehabbed and epoxied.
June 2025: VIS spearheaded a free testing and demonstration of new sealant technology on the decayed lines
of the Wastewater Treatment Facility to promising results. A contract with Telstar for Scada repairs and
upgrades is in review.
June 27, 2025: City Council renewed the proclamation of emergency to address additional contracts required
for completing emergency repairs and approved a budget amendment to the 2024/25 fiscal year appropriating
$800,000 in funds for the Wastewater Treatment Facility emergency repairs. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-43.
July 17, 2025: City Council renewed the proclamation of emergency to address additional contracts required
for completing emergency repairs. The renewal emphasized the necessity for continued immediate repairs
without formal competitive requirements. Reference Resolution 2025-55.
July/August 2025: Repairs are underway on Clarifier #2, which has also received extensive coating with
Mainstay for enhanced durability. Preparations have begun for the Digester rehabilitation project, a
comprehensive effort expected to span over 30 days. The scope includes mechanical repairs, replacement of

Page 66

Page 67 of 179




various pipes and valves, and application of Mainstay coating to the dome structure. Staff have been meeting
with Telstar and are preparing to upgrade the SCADA system.
August 7, 2025: City Council approved the contract with Diamond Weld to construct a new Sludge Tank.
This addition is a key component of the broader Digester rehabilitation initiative.
August 21, 2025: City Council renewed the proclamation of emergency to address additional contracts
required for completing emergency repairs. The renewal emphasized the necessity for continued immediate
repairs without formal competitive requirements. Reference Resolution 2025-70.
August 22, 2025: VIS has initiated cleaning operations on the digester in preparation for the upcoming
rehabilitation project. Rockeez has placed orders for the necessary materials, and epoxy application to the
digester dome is expected to last approximately five weeks, marking a key phase in completing the digester
rehabilitation effort.
September 4, 2025: City Council renewed the proclamation of emergency. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-72.
September 18, 2025: Diamond Weld Industries met with the City and went over scope to demolition the
existing sludge tank and fabricate a new one on site. Work is scheduled to begin September 29,2025 and will
last approximately 3 weeks. VIS finalized their cleaning operations of the Digester. Rockeez began the
process of repairing and replacing piping, valves and gauges on the Digester as well as mobilizing for the
Digester Dome rehab project. Clarifier #2 warranty work commenced and is scheduled for completion
September 21 & 22, 2025. City Council renewed the proclamation of emergency. The renewal emphasized
the necessity for continued immediate repairs without formal competitive requirements. Reference
Resolution 2025-75.
September 19, 2025: Clarifier #2 was reinforced with a chicken wire concrete bottom and then Mainstay
coating was applied. The Mainstay has cured, and the mechanicals components and arms will be reinstalled
9/23. Ongoing repair and replacing of piping, valves and gauges on the Digester. Several parts on order and
completion date depended on the arrival of said parts.
September 30, 2025: Clarifier #2 is back in service. The sludge tank is demolished, and materials are being
brought for the onsite construction of the new tank to begin on 10/2.
October 2, 2025: City Council renewed the proclamation of emergency. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-79.
October 13, 2025: Clarifier 2 was previously taken out of service for warranty repairs and is now back in
service. Sludge Tank is complete and undergoing testing. Thickener Clarifier and Digester Dome
rehabilitation are still on schedule for November 2025.
October 16, 2025: City Council renewed the proclamation of emergency. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-82.
October 20, 2025: Contractor commenced scaffolding set up for Digester Dome Rehab and the Draining of
Thickener Clarifier commenced, with sludge temporarily routed to the sludge drying beds.
November 4, 2025: Contractor commenced sandblasting of Digester in preparation for epoxy coating. The
Thickener Clarifier is offline, and the mechanicals have been removed in preparation for sandblasting and
epoxy. The mechanical components will need to be fabricated and repaired.
November 6, 2025: City Council renewed the proclamation of emergency. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-86.
November 20, 2025: Scaffolding scheduled to be removed first week in December. Working to fix piping,
gauges and meters. Working to get quotes for DAF, Roughing Filter and Clarifier 3.

Page 67

Page 68 of 179


November 25, 2025: Scaffolding removed. Repairs to Digester still ongoing with parts on order.
December 2, 2025: Received quote for Thickener rebuild in stainless steel, $55,380.43. Repairing and
replacing the skimmer arms, rakes and column with stainless steel extends the lifespan of these critical
components. Stainless steel resists rust and chemical attack far better than carbon steel, especially in
wastewater environments where exposure to moisture, sludge, and chemicals is constant.
December 4, 2025: City Council renewed the proclamation of emergency. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-89.
December 2025: Digester columns repaired and dome is epoxy sealed. Repairs are underway for the valves,
meters, cracked lines and plugged lines. SCADA PLC programming is complete, upgrade progress meeting
set for January 8th. Thickener Clarifier work continues.
December 18, 2025: City Council renewed the proclamation of emergency. The renewal emphasized the
necessity for continued immediate repairs without formal competitive requirements. Reference Resolution
2025-95.
January 2026: VIS inspected Digester piping and found a significant portion is still usable, which will reduce
the extra amount of repairs and additional cost needed to replace piping. Approximately 60% of the Thickener
Clarifier project is completed.
January 12, 2026: Telstar performed fiber optics terminations and is working with the City’s IT, Unity, to
verify the fiber optics connections for the new PLC cutovers and system. PLC Cutover’s for PLC B and
Industrial began 1/27/2026 and the next follow up meeting is scheduled for 2/3/2026.
January 29, 2026: Telstar has completed approximately 45% of the SCADA upgrades. Work is still
expected to be completed by end of March 2026. Rockeez is custom fabricating parts for the Thickener
Clarifier and staff are working to replace several broken valves.
February 2026: As work on the Digester is wrapping up, staff will be seeking an outside expert consultant
to assistant in the start up of the Digester as well as train staff for proper use and maintenance. Staff are
working to bring a contract and quote for the DAF unit repairs and coating.

Note: Due to the age and condition of existing infrastructure at the Wastewater Treatment Facility,
additional deficiencies may be identified as work progresses. As such, all dates and milestones are subject
to revision in response to emerging operational needs, safety considerations, or unforeseen complications.
REASON FOR RECOMMENDATION:
These emergency repairs are critical to ensure the protection of health, safety, and welfare of City residents
and to protect the Wastewater Treatment Facilities. The City’s Domestic and Industrial Wastewater
Page 68

Page 69 of 179

Treatment Plant are still undergoing critical maintenance and repair. Remaining tasks include cleaning,
inspecting, repairing, and applying new epoxy remaining clarifiers, the thickener, and the DAF unit coating
and repairs, inspecting, repairing, and replacing the decayed lines leading from Headworks as well as
refurbishing. Additionally, as repair and maintenance efforts progress, previously unanticipated
deficiencies and infrastructure issues have continued to emerge, necessitating immediate attention to
prevent further system degradation and ensure uninterrupted plant operations.
FISCAL IMPACT:
The exact fiscal impact is not fully known at this time as the work is being performed on a Time and
Material basis due to the time sensitivity, but Staff will provide an updated budget for the project at further
upcoming Council meetings.
Any additional costs for more repairs and materials will be brought back to City Council and addressed
appropriately. The costs will be funded from Sewer Enterprise funds.
ALTERNATIVES:
No recommended alternatives. Until all repairs and maintenance are done, the Wastewater Treatment Plant
remains non-compliant.
ACTIONS FOLLOWING APPROVAL:
Per the Resolution, Staff will provide Council updates and seek ratification of any contracts at those meetings.

Page 69

Page 70 of 179

ATTACHMENT 1

Page 70

Page 71 of 179

RESOLUTION NO. 2026.04
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SANGER CONTINUING
THE DECLARATION PROCLAIMING THE EXISTENCE OF A LOCAL EMERGENCY
REGARDING THE SANGER DOMESTIC WASTEWATER TREATMENT FACILITY
AND THE INDUSTRIAL WASTEWATER TREATMENT FACILITY
WHEREAS, the City of Sanger operates the Sanger Domestic Wastewater Treatment
Facility and the Industrial Wastewater Treatment Facility (hereafter "Domestic and Industrial
Wastewater Facilities" ; and
WHEREAS, the City Manager to serve as the Director of Emergency Services issued a
proclamation of local emergency for emergency repairs, which included (but is not limited to) the
following: Digester repairs as needed after inspection; repairs as needed to the domestic headworks
including epoxy coating to headwork; draining and inspection of all clarifiers; as well as repairing
mechanical components and epoxy coating to clarifiers, and inspecting, repairing, and replacing
the decayed lines leading from Headworks as well as refurbishing.; and
WHEREAS, the City Council approved and renewed the Director of Emergency Services'
determination on January 15,2026, pursuant to Resolution No. 2026-01 and,
WHEREAS, the City Council has regularly received reports regarding the emergency and
reviewed the need for continuing the local emergency and intended for the same; and

WHEREAS, the City Manager requests that the City Council continue the declaration of a
state of local emergency for the City as impacts regarding emergency repairs to the wastewater
treatment facility continue to be evaluated, repaired, and or mitigated; and
WHEREAS, the existing SCADA system needs upgrading, and the status of the needed
repairs include cleaning, inspecting, repairing, and applying new epoxy to anaerobic digester
including DAF Unit, clarifiers, the thickener, and, inspecting, repairing, and replacing the de-ayed
lines leading from Headworks as well as refurbishing; and
WHEREAS, there is a need to continue the emergency for purposes of procurement to
ensure the City is able to procure the necessary equipment, services, and supplies for those
purposes, without giving notice for bids to let contracts.

WHEREAS, the City Council desires to continue the duration of the declaration of
emergency as there is a need for the same as set forth above.
NOW, THEREFORE the City Council resolves as follows:
Section

1.

The recitals herein are incorporated herein by reference.

2.

Section
The City Council has reviewed the need for continuing the local emergency
and finds that the state of emergency conditions related to the Domestic and Industrial Wastewater

Page 71

Page 72 of 179

Facilities are ongoing and are recognized as an imminent threat to our citizens. In accordance with
Public Contracts Code Secti on 22050 and Sanger City Code Section 2-206 (h), the public interest
and necessity demand the immediate expenditure of public money to safeguard life, health, or
property. As such, the City Council extends and continues the declaration of a local emergency
regarding the Domestic Wastewater Treatment Facility and the Industrial Wastewater Treatment
Facility.

3.

The emergency will not permit a delay resulting from a competitive
Section
solicitation for bids, and that the action is necessary to respond to the emergency.

4.

Section
Per Public Contract Code Section 22050 (c ) (1) the City Council shall
review the emergency action at its next regularly scheduled meeting and at every regularly
scheduled meeting thereafter until the action is terminated.
Section

5.

This Resolution shall become effeotive upon adoption.

The foregoing Resolution was considered by the City Council for the City of Sanger at a
regular meeting of said Council held on the 5th day of February 2026, and approved by the
following vote:

AYES:
NOES:
ABSTAIN:
ABSENT:

GONZALEZ, MARTINEZ, HURTADO, MONTELONGO, MELENDEZ
l\l.J-t\,tr

NONE
NONE

a rmrdT_

AI l-DDI:

Lina Martinez, City Clerk

Page 72

Page 73 of 179

RESOLUTION NO. 2026-11
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SANGER CONTINUING
THE DECLARATION PROCLAIMING THE EXISTENCE OF A LOCAL EMERGENCY
REGARDING THE SANGER DOMESTIC WASTEWATER TREATMENT FACILITY
AND THE INDUSTRIAL WASTEWATER TREATMENT FACILITY
WHEREAS, the City of Sanger operates the Sanger Domestic Wastewater Treatment
Facility and the Industrial Wastewater Treatment Facility (hereafter “Domestic and Industrial
Wastewater Facilities”); and
WHEREAS, the City Manager serves as the Director of Emergency Services and issued a
proclamation of local emergency for emergency repairs, which included (but is not limited to) the
following: Digester repairs as needed after inspection; repairs as needed to the domestic headworks
including epoxy coating to headwork; draining and inspection of all clarifiers; as well as repairing
mechanical components and epoxy coating to clarifiers, and inspecting, repairing, and replacing
the decayed lines leading from Headworks as well as refurbishing.; and
WHEREAS, the City Council approved and renewed the Director of Emergency Services’
determination on February 5, 2026, pursuant to Resolution No. 2026-04; and
WHEREAS, the City Council has regularly received reports regarding the emergency and
reviewed the need for continuing the local emergency and intended for the same; and
WHEREAS, the City Manager requests that the City Council continue the declaration of a
state of local emergency for the City as impacts regarding emergency repairs to the wastewater
treatment facility continue to be evaluated, repaired, and or mitigated; and
WHEREAS, the existing Supervisory Control and Data Acquisition (SCADA) system
needs upgrading, and the status of the needed repairs include cleaning, inspecting, repairing, and
applying new epoxy to anaerobic digester including DAF Unit, clarifiers, the thickener, and,
inspecting, repairing, and replacing the decayed lines leading from Headworks as well as
refurbishing; and
WHEREAS, there is a need to continue the emergency for purposes of procurement to
ensure the City is able to procure the necessary equipment, services, and supplies for those
purposes, without giving notice for bids to let contracts.
WHEREAS, the City Council desires to continue the duration of the declaration of
emergency as there is a need for the same as set forth above.
NOW, THEREFORE the City Council resolves as follows:
Section 1.

The recitals herein are incorporated herein by reference.

Page 73

Page 74 of 179

Section 2.
The City Council has reviewed the need for continuing the local emergency
and finds that the state of emergency conditions related to the Domestic and Industrial Wastewater
Facilities are ongoing and are recognized as an imminent threat to our citizens. In accordance with
Public Contracts Code Section 22050 and Sanger City Code Section 2-206 (h), the public interest
and necessity demand the immediate expenditure of public money to safeguard life, health, or
property. As such, the City Council extends and continues the declaration of a local emergency
regarding the Domestic and Industrial Wastewater Facility.
Section 3.
The emergency will not permit a delay resulting from a competitive
solicitation for bids, and that the action is necessary to respond to the emergency.
Section 4.
Per Public Contract Code Section 22050(c)(1) the City Council shall
review the emergency action at its next regularly scheduled meeting and at every regularly
scheduled meeting thereafter until the action is terminated.
Section 5.

This Resolution shall become effective upon adoption.

The foregoing Resolution was considered by the City Council for the City of Sanger at a
regular meeting of said Council held on the 19th day of February 2026, and approved by the
following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:
ATTEST:

Lina Martinez, City Clerk

Page 74

Page 75 of 179

For the Meeting of:
Agenda Item No.:

February 19, 2026

E-7

CITY OF SANGER
REPORT TO THE CITY COUNCIL
To:

Mayor and City Council

From:

Esperanza Rosales, Public Works Director

Subject:

Authorization for Out of State Travel – Water Operations Manager

CONFLICT OF INTEREST
None known.
RECOMMENDATION
Staff recommend that the City Council authorize out of state travel for Water Operations Manager to attend
the California Rural Water Association (CRWA) Education and Exhibitor Expo in South Lake Tahoe,
Nevada from April 27 – 30, 2026.
EXECUTIVE SUMMARY
The CRWA Expo is a premier event for water and wastewater professionals, providing essential technical
training, regulatory updates, and exposure to new industry technologies. For the Water Operations
Manager, this conference offers a specialized platform to engage with state and federal regulators and
industry peers to ensure Sanger’s water infrastructure remains compliant and efficient.
BACKGROUND
The California Rural Water Association is dedicated to supporting small to medium-sized water and
wastewater systems through specialized training and legislative advocacy. Their annual Expo serves as a
critical hub for continuing education units (CEUs) required for state certifications and offers workshops
on the latest advancements in water quality management and infrastructure sustainability.
Prepared by:

Esperanza Rosales____

REVIEW: City Manager: ______
TYPE OF ITEM:
ACTION

_X__
____
_X__
____
____

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Approved by: __Esperanza Rosales_________________
Finance: _______

City Attorney: ______

COUNCIL ACTION:  APPROVED  DENIED  NO

____
____
____
____

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 75

Page 76 of 179

REASON FOR RECOMMENDATION
Authorizing the Water Operations Manager’s attendance provides several key benefits to the City:


Ability to earn required contact hours to maintain state mandated water distribution and treatment
certifications.
Provides direct access to sessions regarding upcoming changes in State Water Resources Control
Board regulations, ensuring the City remains proactive in its compliance efforts.
The exhibition portion of the conference allows for the evaluation of new technologies in leak
detection, meter reading, and SCADA systems, which can lead to long-term cost savings for the
City’s utility operations.
Collaboration with managers from similar municipalities for the exchange of best practices
regarding drought management and infrastructure aging.

FISCAL IMPACT
The total estimated fiscal impact for this travel is $1,800, which includes registration fees, lodging, meals,
and transportation. Sufficient funds have been budgeted and are currently available in the FY 2025-2026
Water Enterprise Fund.
ALTERNATIVES
The City Council could choose not to authorize the travel; however, this may require the Water
Operations Manager to seek alternative opportunities.
ACTIONS FOLLOWING APPROVAL
The Public Works Department will confirm registration, travel arrangements, and lodging
accommodations.

Page 76

Page 77 of 179

For the Meeting of:
Agenda Item No.:

CITY OF SANGER

February 19, 2026

E-8

REPORT TO THE CITY COUNCIL
To:

Mayor and Councilmembers

From:

Shaffer Fluetsch, Management Analyst

Subject:

Water Valve Assessment Project

Attachments:

1) Agreement
2) Memo
3) Quote Comparison

CONFLICT OF INTEREST:
None known.
RECOMMENDATION:
Staff recommend that the City Council authorize the City Manager to enter into an agreement with
Specialized Utility Services Program (SUSP) for the Water Valve Assessment Project in an amount not
to exceed $95,000, and find that the award of the same is in compliance with the City’s purchasing
policies for the reasons set forth herein, and is in the best interests of the City.
EXECUTIVE SUMMARY:
Staff requests that the City Council approve agreement with Specialized Utility Services Program
(SUSP) to assess the mapping, condition, and functionality of 200 high priority water valves. Based on
the number of hours that the consultant estimates it will take to perform the assessment, the city estimates
the assessment will cost approximately $80,350 with the clause that the total project cost does not exceed
$95,000. Fund for this project are currently appropriated in the FY 2025/26 in the Water Enterprise
Fund.
BACKGROUND:
Prepared by: _Shaffer Fluetsch

_

REVIEW: City Manager: ______
TYPE OF ITEM:

_X _
____
_X__
____
____

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Approved by: __Esperanza Rosales________________
Finance: _______

City Attorney: ______

COUNCIL ACTION:  APPROVED  DENIED  NO ACTION

____
____
____
____

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 77

Page 78 of 179

Having carefully chosen water valves assessed is a strategic investment that will enhance the efficiency of
our operations, provide a safer working environment for our staff, and will create a more reliable
infrastructure within our water distribution system.
Staff researched and held meetings with several contractors including Specialized Utility Services Program
(SUSP), ME Simpson, and Valve Kings to ascertain if they had the ability to perform the scope of work
the City of Sanger requires on this project. Public Works staff meticulously evaluated the information and
proposals each contractor presented; and after reviewing cost, staffing and equipment to be used, and the
ability to effectively perform the necessary scope of work, it is recommended that SUSP is the best choice
for the City and our team.
Staff obtained quotes from different contractors in order to compare who could provide the best value to
the City of Sanger. Items considered when evaluating the total cost of the project were the number of days
the project would take, the number of staff that would be provided for the project, and if there were any
mobilization fees involved.
SUSP is going to provide a minimum of four operators and one GIS technical specialist for the water valve
assessment project. The scope of services includes:




Exercising and documenting valves within the boundaries predetermined by the City
Providing the City with a complete GIS map and updating city plats with accurate valve locations
Providing detailed notes about the condition of each valve
Documenting shutdown capabilities and identifying areas where isolation is currently unachievable.
Preparing a corrective action plan based on assessment findings.

In many high-priority areas of the City, achieving a water shutdown is currently difficult or impossible due
to aged infrastructure, missing valves, or inaccurate mapping. When a valve fails to isolate an area, staff
must seek out more distant valves, often repeating the process several times. This creates issues such as
extended downtime, increased labor hours, and delays in repairs.
Reliable valve isolation is essential not only for emergency maintenance but also to support City growth
as we currently have numerous street Capital Improvement Program (CIP) Projects and Private Developer
Projects that depend on this system’s reliability to stay on schedule and within budget.
By doing this assessment, we will provide staff with a more functional distribution system, and the project
will greatly enhance the capabilities of the Public Works Department and provide improvements to our
water valve inventory.
REASON FOR RECOMMENDATION:
Currently, City staff must rely on a system of water valves that cannot always provide a reliable water
shutdown greatly reducing operating efficiency and the ability to perform inspections or make repairs. By
investing in this assessment, we can greatly increase our efficiency and create a safer working environment
for our staff.
FISCAL IMPACT:
The FY2025/26 budget has existing appropriations in the Water Division Enterprise Fund, account #611Page 78

Page 79 of 179

070-401-7205, for the water valve assessment project. The total cost of the project is not to exceed $95,000.
ALTERNATIVES:
Do not approve the project. Staff will continue working with valves that aren’t fully functional and maps
that aren’t up-to-date.
ACTIONS FOLLOWING APPROVAL:
Once approved the City Manager will sign the agreement on behalf of the City, and the project can then
commence in April 2026. The project is expected to be completed by the end of the 2026 fiscal year (June
30, 2026).

Page 79

Page 80 of 179

ATTACHMENT 1

Page 80

Page 81 of 179

CITY OF SANGER
CONSULTANT SERVICES AGREEMENT
This Consultant Services Agreement ("Agreement”) is entered into between the CITY OF
SANGER, a California general law city (“City”) and SPECIALIZED UTILITY SERVICES
PROGRAM, INC. ("Consultant”). This Agreement shall be effective on the date signed by City
which shall occur after execution by Consultant (“Effective Date”).
RECITALS
A.
City desires to ensure its water system is in working order, especially in high-priority
areas of the City where achieving a water shutdown is currently difficult or impossible due to aged
infrastructure, missing valves, or inaccurate mapping. As part of this purpose, the City desires to
have assessments performed for key locations as identified by the City.
B.
Consultant is engaged in the business of furnishing such services as a consultant and
warrants and represents that it is qualified, licensed, and professionally capable of performing the
Services called for in this Agreement.
C.
City has selected Consultant to perform the requested Scope of Services on the basis
of Consultant's demonstrated competence and professional qualifications.
D.
City desires to retain Consultant, and Consultant desires to provide City with the
Services, on the terms and conditions as set forth in this Agreement.
NOW, THEREFORE, in consideration of the promises and mutual agreements herein, City
and Consultant agree as follows:
AGREEMENT
1.
Scope of Services. Consultant shall perform, to the satisfaction of City in accordance with
this Agreement, the Services described in the “Scope of Services” set forth in Exhibit A attached
hereto and incorporated by reference herein, and as may be revised by mutual agreement of the
parties. Consultant warrants that it is qualified to perform the Services under this Agreement.
Consultant shall be familiar with and shall comply with all State and Federal laws and regulations
applicable to the work to be performed under this Agreement.
2.
Commencement of Services; Term of Agreement. Consultant shall commence the Services
upon City’s issuance of a written "Notice to Proceed" and shall continue with the Services until
Consultant, as determined by City, has satisfactorily performed and completed the Services, or until
such time as the Agreement is terminated by either party in accordance with this Agreement,
whichever is earlier.
(a)
Continuity of Personnel. Consultant shall make every reasonable effort to maintain
the stability and continuity of Consultant's staff and subcontractors assigned to perform the
Services under this Agreement. Consultant shall notify City of any changes in Consultant's
staff and subcontractors assigned to perform the Services under this Agreement.
01484.0021 2089486.1

1

Page 81

Page 82 of 179

(b)
Additional Services. Consultant shall not be compensated for any services rendered in
connection with its performance of this Agreement which are in addition to or outside of those set
forth in this Agreement or listed in Exhibit "A," unless such additional services are authorized in
advance and in writing by the City Manager of City. Consultant shall be compensated for any such
additional services in the amounts and in the manner agreed to by the City and Consultant.
3.
Compensation for Services. City shall compensate Consultant for rendering the Services as
follows:
(a)
Subject to any limitations set forth in this Agreement, City agrees to pay Consultant per
one invoice. Both parties agree that Consultant’s proposal to complete the Services is not to
exceed ninety five thousand dollars and no cents ($95,000) and that the Services are anticipated
to be completed by June 30, 2026.
(b)
Each month Consultant shall invoice City for all work performed and expenses incurred
during the preceding month. The invoice shall detail charges by the following categories: labor
(by subcategory), travel, materials, equipment, supplies, and sub-consultant contracts.
(c)
City shall independently review each invoice submitted by the Consultant to determine
whether the work performed and expenses incurred are in compliance with the provisions of this
Agreement. The invoiced amount shall be paid within 30 calendar days unless City disputes any
charges or expenses. If any charges or expenses are disputed, City shall pay the undisputed
amount and notify Consultant of the nature and amount of the disputed charge or expense. The
parties shall seek to resolve the disputed items(s) by mutual agreement.

4.
Independent Contractor Status. Consultant and its subcontractors shall perform the Services
as independent contractors and not as officers, employees, agents or volunteers of City. Nothing
contained in this Agreement shall be deemed to create any contractual relationship between City and
Consultant’s employees or subcontractors, nor shall anything contained in this Agreement be deemed
to give any third party, including but not limited to Consultant’s employees or subcontractors, any
claim or right of action against City.
5.
Standard of Care. Consultant represents and warrants that it has the qualifications, experience
and facilities necessary to properly perform the services required under this Agreement in a thorough,
competent and professional manner. Consultant shall at all times faithfully, competently and to the
best of its ability, experience and talent, perform all services described herein. In meeting its
obligations under this Agreement, Consultant shall employ, at a minimum, generally accepted
standards and practices utilized by persons engaged in providing services similar to those required of
Consultant under this Agreement. Consultant represents that to the extent Consultant utilizes
subcontractors, such subcontractors are, and will be, qualified in their fields. Consultant also
expressly represents that both Consultant and its subcontractors, if any, are now, and will be
throughout their performance of the Services under this Agreement, properly licensed or otherwise
qualified and authorized to perform the Services required and contemplated by this Agreement.
Consultant and its subcontractors, if any, shall utilize the standard of care and skill customarily
exercised by members of their profession, shall use reasonable diligence and best judgment while
performing the Services, and shall comply with and keep themselves informed of all applicable laws
and regulations.
01484.0021 2089486.1

2

Page 82

Page 83 of 179

6.
Identity of Subcontractors and Sub-Consultants. Consultant shall, before commencing any
work under this Agreement, provide to City in writing: (a) the identity of all subcontractors and
sub-consultants (collectively referred to as "subcontractors"), if any, Consultant intends to utilize in
Consultant's performance of this Agreement; and (b) a detailed description of the full scope of work
to be provided by such subcontractors. Consultant shall only employ subcontractors pre-approved by
City and in no event shall Consultant replace an approved subcontractor without the advance written
permission of City, with the understanding that City’s permission will not be unreasonably withheld.
Notwithstanding any other provisions in this Agreement, Consultant shall be liable to City for the
performance of Consultant's subcontractors.
7.
Subcontractor Provisions. Consultant shall include in its written agreements with its
subcontractors, if any, provisions which: (a) impose upon the subcontractors the obligation to provide
to City the same insurance and indemnity obligations that Consultant owes to City; (b) make clear
that City intends to rely upon the reports, opinions, conclusions and other work product prepared and
performed by subcontractors for Consultant; and (c) entitle City to impose upon subcontractors the
assignment rights found elsewhere in this Agreement.
8.
Power to Act on Behalf of City. Consultant shall not have any right, power, or authority to
create any obligation, express or implied, or make representations on behalf of City except as may be
expressly authorized in advance in writing from time to time by City and then only to the extent of
such authorization.
9.
Record Keeping; Reports. Consultant shall keep complete records showing the type of
Services performed. Consultant shall be responsible and shall require its subcontractors to keep
similar records. City shall be given reasonable access to the records of Consultant and its
subcontractors for inspection and audit purposes. Consultant shall provide City with a working draft
of all reports and five (5) copies of all final reports prepared by Consultant under this Agreement.
10.
Ownership and Inspection of Documents. All data, tests, reports, documents, conclusions,
opinions, recommendations and other work product generated by or produced for Consultant or its
subcontractors in connection with the Services, regardless of the medium, including physical
drawings and materials recorded on computer discs (“Work Product”), shall be and remain the
property of City. City shall have the right to use, copy, modify, and reuse the Work Product as it sees
fit. Upon City’s request, Consultant shall make available for inspection and copying all such Work
Product and all Work Product shall be turned over to City promptly at City’s request or upon
termination of this Agreement, whichever occurs first. Consultant shall not release any Work Product
to third parties without prior written approval of the City Manager. This obligation shall survive
termination of this Agreement and shall survive for four (4) years from the date of expiration or
termination of this Agreement.
11.
Confidentiality. All data, reports, conclusions, opinions, recommendations and other work
product prepared and performed by and on behalf of Consultant in connection with the Services
performed pursuant to this Agreement shall be kept confidential and shall be disclosed only to City,
unless otherwise provided by law or expressly authorized by City. Consultant shall not disclose or
permit the disclosure of any confidential information acquired during performance of the Services,
except to its agents, employees, affiliates, and subcontractors who need such confidential information
01484.0021 2089486.1

3

Page 83

Page 84 of 179

in order to properly perform their duties relative to this Agreement. Consultant shall also require its
subcontractors to be bound to these confidentiality provisions.
12.
City Name and Logo. Consultant shall not use City’s name or insignia, photographs relating
to the City projects for which Consultant’s services are rendered, or any publicity pertaining to the
Consultant’s services under this Agreement in any magazine, trade paper, newspaper, television or
radio production or other similar medium without the prior written consent of City.
13.
Conflicts of Interest. Consultant warrants that neither Consultant nor any of its employees
have an interest, present or contemplated, in the Services. Consultant further warrants that neither
Consultant nor any of its employees have real property, business interests or income that will be
affected by the Services. Consultant covenants that no person having any such interest, whether an
employee or subcontractor shall perform the Services under this Agreement. During the performance
of the Services, Consultant shall not employ or retain the services of any person who is employed by
the City or a member of any City Board or Commission. City understands and acknowledges that
Consultant is, as of the date of execution of this Agreement, independently involved in the
performance of non-related services for other governmental agencies and private parties. Consultant
is unaware of any stated position of City relative to such projects. Any future position of City on
such projects shall not be considered a conflict of interest for purposes of this section. City
understands and acknowledges that Consultant will, perform non-related services for other
governmental agencies and private parties following the completion of the Services under this
Agreement, and any such future service shall not be considered a conflict of interest for purposes of
this section.
14.
Non-liability of Officers and Employees. No officer or employee of City shall be personally
liable to Consultant, or any successors in interest, in the event of a default or breach by City for any
amount which may become due Consultant or its successor, or for any breach of any obligation under
the terms of this Agreement.
15.
City Right to Employ Other Consultants. This Agreement is non-exclusive with Consultant.
City reserves the right to employ other consultants in connection with the Services.
16.
Termination of Agreement. This Agreement shall terminate upon completion of the Services,
or earlier pursuant to the following.
a..
Termination by City: Without Cause. This Agreement may be terminated by City at
its discretion upon thirty (30) days prior written notice to Consultant.
b.
Termination by City or Consultant: For Cause. Either party may terminate this
Agreement upon twenty (20) days prior written notice to the other party of a material breach, and a
failure to cure within that time period.
c.
Compensation to Consultant Upon Termination. In the event termination is not due to
fault attributable to Consultant and provided all other conditions for payment have been met,
Consultant shall be paid compensation for services performed prior to notice of termination. As to
any phase partially performed but for which the applicable portion of Consultant's compensation has
not become due, Consultant shall be paid the reasonable value of its services provided. However, in
01484.0021 2089486.1

4

Page 84

Page 85 of 179

no event shall such payment when added to any other payment due under the applicable part of the
work exceed the total compensation of such part as specified in Section 3 herein. In the event of
termination due to Consultant’s failure to perform in accordance with the terms of this Agreement
through no fault of City, City may withhold an amount that would otherwise be payable as an offset
to City's damages caused by such failure.
d.
Effect of Termination. Upon receipt of a termination notice (or completion of this
Agreement), Consultant shall: (i) promptly discontinue all Services affected (unless the notice directs
otherwise); and (ii) deliver or otherwise make available to the City, without additional compensation,
all data, documents, procedures, reports, estimates, summaries, and such other information and
materials as may have been accumulated by the Consultant in performing this Agreement, whether
completed or in process. Following the termination of this Agreement for any reason whatsoever,
City shall have the right to utilize such information and other documents, or any other works of
authorship fixed in any tangible medium of expression, including but not limited to physical drawings,
data magnetically or otherwise recorded on computer disks, or other writings prepared or caused to
be prepared under this Agreement by Consultant. Consultant may not refuse to provide such writings
or materials for any reason whatsoever.
17.
Insurance. Consultant shall obtain and maintain in full force and effect during the term of this
Agreement the insurance policies set forth in Exhibit "B" attached hereto and incorporated herein
by this reference. All insurance policies shall be subject to City approval as to form and content.
Consultant shall provide City with copies of required certificates of insurance upon request.
18.
Indemnity and Defense. Consultant hereby agrees to indemnify, defend and hold the City, its
officials, officers, employees, agents, and volunteers harmless from and against all claims, demands,
causes of action, actions, damages, losses, expenses, and other liabilities, (including without
limitation reasonable attorney fees and costs of litigation) of every nature arising out of the acts,
errors, or omissions constituting negligence, gross negligence, willful misconduct or fraud of
Consultant or its subcontractors relating to the performance of Services described herein. Consultant's
duty to defend and indemnify City shall not extend to injuries or damages that are the result of City's
sole negligence or willful misconduct.
Consultant’s duty to defend shall immediately arise when a claim is asserted and/or a lawsuit
is initiated against the City arising out of or occurring in connection with the acts, errors, or omissions
constituting negligence, gross negligence, fraud or willful misconduct of Consultant or its
subcontractors relating to the performance of Services described herein and regardless of whether
others may owe the City a duty of defense and/or indemnity. Consultant and City agree that said
indemnity and defense obligations shall survive the expiration or termination of this Agreement for
any items specified herein that arose or occurred during the term of this Agreement for a period of
two (2) years.
19.
Assignment. Neither this Agreement nor any duties or obligations hereunder shall be
assignable by Consultant without the prior written consent of City. In the event of an assignment to
which City has consented, the assignee shall agree in writing to personally assume and perform the
covenants, obligations, and agreements herein contained. In addition, Consultant shall not assign the
payment of any monies due Consultant from City under the terms of this Agreement to any other
01484.0021 2089486.1

5

Page 85

Page 86 of 179

individual, corporation or entity. City retains the right to pay any and all monies due Consultant
directly to Consultant.
20.
Form and Service of Notices. All notices required or permitted to be given under this
Agreement shall be in writing and shall be personally delivered, or sent by certified mail, postage
prepaid and return receipt requested, addressed as follows:
To City:

Public Works Department
City of Sanger
1700 7th Street
Sanger, CA 93637

To Consultant: Dan DeMoss
Specialized Utility Services Program
1234 North Market Blvd
Sacramento, CA 95834

Notice shall be deemed effective on the date personally delivered or transmitted by facsimile, or if
mailed, three (3) days after deposit of the same in the custody of the United States Postal Service.
21.
Entire Agreement. This Agreement, including the attachments, represents the entire
Agreement between City and Consultant and supersedes all prior negotiations, representations or
agreements, either written or oral with respect to the subject matter herein. This Agreement may be
amended only by written instrument signed by both City and Consultant.
22.
Successors and Assigns. This Agreement shall be binding upon and shall inure to the benefit
of the parties hereto and their respective successors and assigns.
23.
Authority. The signatories to this Agreement warrant and represent that they have the legal
right, power, and authority to execute this Agreement and bind their respective entities.
24.
Severability. In the event any term or provision of this Agreement is declared to be invalid or
illegal for any reason, this Agreement will remain in full force and effect and will be interpreted as
though such invalid or illegal provision were not a part of this Agreement. The remaining provisions
will be construed to preserve the intent and purpose of this Agreement and the parties will negotiate
in good faith to modify any invalidated provisions to preserve each party’s anticipated benefits.
25.
Applicable Law and Interpretation and Venue. This Agreement shall be interpreted in
accordance with the laws of the State of California. The language of all parts of this Agreement shall,
in all cases, be construed as a whole, according to its fair meaning, and not strictly for or against either
party. This Agreement is entered into by City and Consultant in the County of Fresno, California.
Consultant shall perform the Services required under this Agreement in the County of Fresno,
California. Thus, in the event of litigation, venue shall only lie with the appropriate state or federal
court in Fresno County.
26.
Attorneys Fees. If either party is required to commence any proceeding or legal action to
enforce or interpret any term, covenant, or condition of this Agreement, the prevailing party in such
proceeding or action shall be entitled to recover from the other party its reasonable attorneys’ fees
and legal expenses.
27.
Amendments and Waiver. This Agreement shall not be modified or amended in any way, and
no provision shall be waived, except in writing signed by the parties hereto. No waiver of any
01484.0021 2089486.1

6

Page 86

Page 87 of 179

provision of this Agreement shall be deemed, or shall constitute, a waiver of any other provision,
whether or not similar, nor shall any such waiver constitute a continuing or subsequent waiver of the
same provision. Failure of either party to enforce any provision of this Agreement shall not constitute
a waiver of the right to compel enforcement of the remaining provisions of this Agreement.
28.
Third Party Beneficiaries. Nothing in this Agreement shall be construed to confer any rights
upon any party not a signatory to this Agreement.
29.
Execution in Counterparts. This Agreement may be executed in counterparts such that the
signatures may appear on separate signature pages. A copy or an original, with all signatures
appended together, shall be deemed a fully executed Agreement.
30.
Non-Discrimination. Consultant shall not discriminate on the basis of any protected class
under federal or State law in the provision of the Services or with respect to any Consultant employees
or applicants for employment. Consultant shall ensure that any subcontractors are bound to this
provision. A protected class, includes, but is not necessarily limited to race, color, national origin,
ancestry, religion, age, sex, sexual orientation, marital status, and disability.
31.
Compliance with All Laws. In providing the services required under this Agreement,
Consultant shall at all times comply with all applicable laws of the United States, the State of
California, and with all applicable regulations promulgated by federal, state, regional, or local
administrative and regulatory agencies, now in force and as they may be enacted, issued, or amended
during the term of this Agreement.
Now, therefore, the City and Consultant have executed this Agreement on the date(s) set forth below.
SPECIALIZED UTILITY SERVICES
PROGRAM, INC.

CITY OF SANGER

By:___________________________
Name & Title: __________________

By:______________________________
Nathan Olson, City Manager

Date: __________________

Date: __________________

01484.0021 2089486.1

7

Page 87

Page 88 of 179

EXHIBIT A

SCOPE OF SERVICES
Consultant will provide four operators and one technical specialist to perform the following work
for City:
a.

Consultant will exercise and document valves located with the boundaries
predetermined by the City.

b.

Consultant will provde the City with a complete GIS map as well as update the City
Plats with accurate valve locations.

c.

Consultant will include notes about the condition of each valve.

d.

Consultant will verify valve shutdowns or lack thereof if there is no shutdown.
Consultant will document how to get proper isolation with each valve.

e.

Consultant will provide the City with a Corrective Action Plan Outlining the findings
of the assessment.

The Parties anticipate the scope of work will require 150 hours of work onsite, as well as 20 hours
of GIS/Mapping and reporting (20-30 hours if current adapting current GIS mapping in ESRI).
Consultant shall provide the services at the following rates, not to exceed the total compensation
authorized by this agreement:
Operator Grades 1-2
Travel

$95.00/hr./operator
Travel to the site location will be
charged at $95.00/hr./operator
$145.00 per hour

GIS/Mapping work and Corrective
Action Plan

01484.0021 2089486.1

8

Page 88

Page 89 of 179

EXHIBIT B
A.

Insurance Requirements

INSURANCE

i.
Consultant shall maintain commercial general liability insurance with coverage at
least as broad as Insurance Services Office form CG 00 01, in an amount not less than two
million dollars ($2,000,000) per occurrence for bodily injury, personal injury, and property
damage, including without limitation, blanket contractual liability. If a general aggregate
limit applies, either the general aggregate limit shall apply separately to this project/location
or the general aggregate limit shall be twice the required occurrence limit. Consultant’s
general liability policies shall be endorsed using Insurance Services Office form CG 20 10
(or equivalent) to provide that City and its officers, officials, employees, and agents shall be
additional insureds under such policies. For construction projects, an endorsement
providing completed operations coverage for the additional insured, ISO form CG 20 37 (or
equivalent), is also required.
ii.
Any failure to comply with reporting provisions of the policies by Consultant shall
not affect coverage provided by the City.
iii.
Coverage shall state that Consultant insurance shall apply separately to each insured
against whom claim is made or suit is brought, except with respects to the limits of the
insurer’s liability.
iv.
Coverage shall contain a waiver of subrogation in favor of the City.
B.

Business Automobile Liability
i.
Consultant shall provide auto liability coverage for owned, non-owned, and hired
autos using ISP Business Auto Coverage form CA 00 01 (or equivalent) with a limit of no
less than two million dollars ($2,000,000) per accident.

C.

Workers’ Compensation and Employers’ Liability
i.
Consultant shall maintain Workers’ Compensation Insurance (Statutory Limits) and
Employers’ Liability Insurance with limits of at least one million dollars ($1,000,000).
Consultant shall submit to City, along with the certificate of insurance, a waiver of
subrogation endorsement in favor of City, its officers, agents, employees, and volunteers.

D.

All Coverages
i.
Each insurance policy required by the agreement shall be endorsed to state that
coverage shall not be suspended, voided, cancelled, or reduced in limits except after thirty
(30) days’ prior written notice has been given to the City, except that ten (10) days’ prior
written notice shall apply in the event of cancellation for nonpayment of premium.
ii.
All self-insurance, self-insured retentions, and deductibles must be declared and
approved by the City.
iii.
Evidence of Insurance – Prior to commencement of work, the Consultant shall
furnish the City with certificates, additional insured endorsements, and waivers of
subrogation evidencing compliance with the insurance requirements above. The Consultant

01484.0021 2089486.1

9

Page 89

Page 90 of 179

must agree to provide complete, certified copies of all required insurance policies of
requested by the City.
iv.
Acceptability of Insurers – Insurance shall be placed with insurers admitted in the
State of California with an AM Best rating of A- VII or higher.

01484.0021 2089486.1

10

Page 90

Page 91 of 179

ATTACHMENT 2

Page 91

Page 92 of 179

MEMORANDUM
PUBLIC WORKS DEPARTMENT
ESPERANZA ROSALES – PUBLIC WORKS DIRECTOR

Date:

February 3, 2026

To:

Esperanza Rosales, Public Works Director

From:

Shaffer Fluetsch, Public Works Management Analyst

Subject:

Water Valve Assessment Project

Please let this memo serve as justification for only using two proposals when deciding which vendor presents
the best value for the water valve assessment project. Staff researched a number of companies to determine if
they had the ability to perform the scope of work the city is wanting to complete. Companies such as McMor
and IWater informed us they wouldn’t be able to perform the work required. Hydromax doesn’t work in
California, and Wachs Utility Products informed us that they only manufacture and don’t perform any services.
After an exhaustive search, we were able to obtain three qualified candidates: Valve King, ME Simpson, and
SUSP. ME Simpson and SUSP were able to provide the city their proposals; however, after many attempts to
get a proposal from Valve King unsuccessfully.
Given the specialized nature of the work and lack of other viable service providers in the region, these two
submissions represent a competitive environment sufficient to determine “best value” for the City. Proceeding
at this time ensures the project remains on schedule and the city’s water infrastructure receives necessary
assessment without further administrative delay.

Page 92

Page 93 of 179

ATTACHMENT 3

Page 93

Page 94 of 179

2/11/2026

City of Sanger
Quote Comparison
Quote #2
Quote #1
ME Simpson
Contractor Name: SUSP
Address:
1234 North Market Blvd 3406 Enterprise Ave
City, St, Zip:
Sacramento, CA 95834 Valparaiso, IN 46383
Phone:
916-553-4900
800-255-1521
Item Description
4 person crew
2 person crew
GIS staff

Sub Total

Options
Report fee
Mobilization

Quote #1
$

76,000.00

$

4,350.00

$

80,350.00 $

Sub Total of Options
GRAND TOTAL
Quote Date
Lead Time
Approximate Start Date
Approximate Completion Date

$

Quote #2
$

Quote #3
Valve King USA
6352 Industry Way
Westminster, CA 92683
310-714-1308
Quote #3

75,000.00

75,000.00 $

$
$

4,000.00
16,400.00

$

20,400.00

80,350.00 $

95,400.00 $

11/18/2025

11/3/2025

-

-

4/1/2025
5/5/2025

Quote Valid until
NOTES:

Costs based on four
Costs based on two
Proposal never
workers onsite for 150 workers onsite for
submitted.
hours and one GIS staff approximately 20 days.
working for 30 hours.

Page 94

Page 95 of 179

1234 North Market Blvd.
Sacramento, CA 95834
toll-free: 800.833.0322
phone: 916.553.4900
fax: 916.553.4904
www.suspinc.org

City of Sanger
Water Valve Assessment Services
November 18, 2025

1. Scope of Services

2. Price Proposal

3. Summary Proposal

Page 95

Page 96 of 179

1. Scope of Services

General Services – Specialized Utility Services Program, Inc. (SUSP) was requested to provide a

proposal for water valve assessment services in the central part of the City of Sanger (City). SUSP
will provide a minimum of four (4) operators and one (1) technical specialist to conduct the
following scope.

a. SUSP will exercise and document valves located within the boundaries predetermined
by the City.
b. SUSP will provide the City with a complete GIS map as well as update the City Plats
with accurate valve locations
c. SUSP will include notes about the condition of each valve.
d. SUSP will verify valve shutdowns or lack thereof if there is no shutdown. SUSP will
document how to get proper isolation with each valve.
e. SUSP will provide the City with a Corrective Action Plan outlining the findings of the
assessment.
2. Price Proposal
SUSP will provide the General Services outlined in Section 1 – Scope of Services, under contract.
This fee is payable within 30 days of receipt of the SUSP invoice for services provided. SUSP
anticipates 150 hours of onsite, as well as 20 hours of GIS/Mapping and reporting.
Operator Grades 1-2
Travel
GIS/Mapping work and
Corrective Action Plan

$95.00/hr./operator
Travel to the site location will be charged at
the above-listed price.
$145.00 per hour
SUSP engineering estimates 20-30 hours
minimum if we adapt current GIS mapping
in ESRI.

3. Proposal Summary
We are flexible in providing services, so please feel free to discuss any aspect of this price proposal
with us for clarification. Upon signing, you agree to the terms outlined in this proposal. This
proposal will act as formal consent for SUSP to facilitate the services listed under Section 1. If
you have any questions or wish to discuss this proposal, please contact Fernando Saenz, SUSP
Operations Manager, [email protected], or Dan DeMoss, SUSP and California Rural Water
Association Executive Director, [email protected].

Page 96

Page 97 of 179

Submitted by:
________________________________
Dan DeMoss, Executive Director
Specialized Utility Services Program, Inc.

11/18/2025
Date

Accepted by:
________________________________
Signature

________________

Date

________________________________
Print Name

________________________________

Title

Page 97

Page 98 of 179

November 3, 2025

Mr. Shaffer Fluetsch
Management Analyst
City of Sanger
1700 7th St
Sanger, CA 93657-2804
RE: PROPOSAL FOR A VALVE ASSESSMENT AND EXERCISING PROGRAM
Dear Mr. Fluetsch,
M.E. Simpson Co., Inc. is delighted to present our proposal to the City of Sanger, CA for a Water
Distribution System Valve Assessment and Exercising Program. We feel privileged to be considered for
this endeavor and are confident that our team will contribute to the success of the project.
As a Professional Services Firm, our primary focus is on developing and delivering programs and services
that optimize the performance of our clients' water distribution systems. Many of these programs are
recognized globally as Best Management Practices (BMPs) for utilities. We take pride in providing robust
solutions through the utilization of top-tier technical and professional services, leveraging state-of-the-art
technology, and employing a highly skilled and well-trained staff of professionals. Our team of educated
engineers and technical experts is fully dedicated to the success of this project and ready to alleviate the
burden on your staff, ensuring a seamless continuation of services.
Our services have been meticulously developed and refined to cater to the specific needs of utilities.
Whether it's offering comprehensive turn-key solutions or assisting in the development of in-house
programs, M.E. Simpson Co., Inc. strives to fulfill one overarching goal: to instill public confidence by
ensuring the safety and quality of drinking water.
We sincerely appreciate your consideration and the opportunity to introduce our valve assessment
services through this proposal. We are committed to surpassing your expectations and delivering
exceptional results.
Sincerely,

Michael Simpson
CEO

Michael Simpson
CEO
3406 Enterprise Avenue
Valparaiso, IN 46383
800.255.1521 P
888.531.2444 F
[email protected]

Page 98

Page 99 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

SCOPE OF SERVICES
Valve Assessment and Exercising Program
At M.E. Simpson Co., Inc., our Valve Assessment and Exercising Program is designed to help utilities ensure
the operability, accuracy, and reliability of critical valve assets across their water distribution systems.
Much like other buried infrastructure, water valves are subject to deterioration, corrosion, and neglect—
issues that can lead to severe service disruptions if left unaddressed. Our program combines decades of
field expertise with disciplined procedures and precision tools to provide water utilities with precise,
actionable data to maintain and optimize their valve networks.

Field Scope of Service
M.E. Simpson Co., Inc. will conduct comprehensive valve assessments in the water distribution system as
determined by the Utility. Here's a condensed breakdown of our field scope of service:
Item

Description

Resource Provisions


Safety Measures


Valve Location





M.E. Simpson Co., Inc. will supply all necessary resources, including
labor, materials, transportation, tools, and equipment
A minimum of Two Persons per team will work on the valve assessment
at all times
Field staff will work in an orderly and safe manner, wearing readily
observable identification badges
We will adhere to the safety specifications outlined for equipment use
Review water maps to locate valves as indicated
Conduct visual inspections and utilize appropriate equipment to locate
valves accurately
Document mapping discrepancies and update existing maps accordingly
Maintain a progression map indicating valves that have been assessed
Apply environmentally formulated paint for future identification

Valve Exercising




Operate valves manually following AWWA M-44 guidelines
Clean valve enclosures for maintenance and inspection purposes
Perform valve operations with minimum torque to prevent damage
Use hydraulic valve machines for valves requiring torque exceeding
specified limits

Valves to be Assessed

Conduct assessments according to the designated areas and report any
issues promptly.

Page 99

Page 100 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

Maintain confidentiality of all collected data and share information with
the Utility as required.


Digitally document all valve inspections based on current AWWA
standards
Record valve operations, locations, and any issues encountered

Quality Control



Maintain strict adherence to a systematic valve assessment procedure
Two-Person Teams to ensure oversight
Advanced correlator technology allows for comprehensive leak coverage

Final Reports and
Communication


Regular meetings with the Utility will ensure ongoing communication
Final reports will include all valve documentation, total number of valves
operated, valves requiring maintenance, and other problems found in
the system during the course of the program that need the attention of
the Utility
Reports provided within thirty (20) working days of project completion

Documentation of
Valve Operations


Assumptions and
Services Provided by
the Utility



Equipment Used








Furnish necessary maps, records, and information for valve assessment
Assist in gaining access to sites and provide personnel with water system
knowledge as needed
Provide Valve ID numbers, map references, and additional information
to facilitate the assessment process
All necessary hand tools
Truck mounted Arrow Board/Signage, and warning lights on trucks
Traffic control equipment, including properly sized traffic cones with
reflective stripes, when needed or required
A “Schonstedt”/“Chicago Tape” magnetic locator
Truck mounted or trailer mounted hydraulic valve operator with
adjustable torque control
Portable hydraulic valve operator adjustable torque control
Truck mounted or trailer mounted Vacuum capable of 300 CFM
Trucks are equipped with either a Honda 6.5 horsepower pump capable
of discharging 150 GPM or a Stanley Hydraulic pump capable of
discharging 450 GPM
Extendable valve keys for manual operation

Page 100

Page 101 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

Field Scope of Service – Shutdowns
M.E. Simpson Co., Inc. will conduct shutdown services on the segments of water main designated through
the comprehensive valve assessment program. Here's a condensed breakdown of our field scope of
service: The crew will isolate specific segments of the water main between two valves, beginning by
setting up a secure traffic and work zone, and preparing the selected valves. They will observe and follow
system hydraulics as closely as possible. They will slowly close the upstream valve, then close the
downstream valve in the same manner, ensuring the valves are fully seated. Once both valves are closed,
bleed the pressure from the isolated segment by installing a pressure gauge and then opening the nearest
hydrant on that pipe segment or blow-off to ensure the flow ceases, and the pressure gauge reads zero.
Once the shutdown has been verified, re-energize the line by slowly opening the selected valves that
created the shutdown.

Page 101

Page 102 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

PROJECT SAFETY PLAN
M.E. Simpson Co., Inc.’s Safety Programs cover all aspects of the work performed by M.E. Simpson Co.,
Inc. We take great pride in our safety program, and that is evident in our EMR scores over the last five
years. The safety of our employees, the utilities employees, and that of the general public is our #1
priority.

“Safety is a significant part of any project. M.E. Simpson Co., Inc. consistently provides a safe work
environment for its employees. Our staff is trained in General Industry OSHA rules, Confined Space
Entry & Self-Rescue, First Responder First Aid, CPR, and Traffic Control. While in the field on your
project, M.E. Simpson Co., Inc., and its employees will follow all of the necessary safety procedures to
protect themselves, your staff, and the general public.”
Our Safety Program, with all of its parts, is 140 pages in length. To be more efficient and less wasteful, we
do not print copies of the safety program for RFPs. There is nothing secretive or proprietary contained
within our safety program, and we are happy to share its contents. If you would like a PDF copy, please
contact Terrence Williams, Operations Manager, at (800) 255-1521, and a copy will be sent to you via
email.
M.E. Simpson Co., Inc. uses Two-Man Teams for Safety and Quality Assurance.
The use of a “one-person” team is dangerous. Many of the utilities' assets are located in roadways,
treatment facilities, and confined spaces. For safety, M.E. Simpson Co., Inc. always deploys a two-person
team.
M.E. Simpson Co., Inc. adheres to the following:
The Project Manager and the Field Manager will be trained in accordance with OSHA Standard 1910
(General Industry) and have an OSHA 10-Hour or 30-Hour Card.
Any activity located in a "confined space", such as pit and vault installations that require entry, will be
treated per the safety rules regarding Confined Space Entry, designated by the Utility, the Department
of Labor, and OSHA. All personnel are trained and certified in Confined Space Entry & Self-Rescue.
We will follow all safety rules regarding First Responder First Aid & CPR, designated by the Utility, the
Department of Labor, and OSHA. All personnel are trained and certified in First Responder First Aid &
CPR.
We will follow all traffic safety rules designated by the Utility, the Department of Labor, OSHA, and
the Department of Transportation. All personnel are trained and certified by the AMERICAN TRAFFIC
SAFETY SERVICES ASSOCIATION (ATSSA) in Traffic Control and Safety.

Current documentation of safety training and certifications can be provided for all project personnel for
the Utility. These certifications are current and up-to-date for all project personnel.

Page 102

Page 103 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

PROPOSED PROJECT SCHEDULE
Project Start Date:

TBD.

Kick-Off Meeting:

TBD after the Project Start Date is finalized.

Completion of Field-Work:

Approximately 20 days.

Final Reports:

Within 20 Business days of Project Completion.

Page 103

Page 104 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

INVESTMENT
A commitment to improving and maximizing the City of
Sanger’s water distribution system for future generations.
M.E. Simpson Co., Inc. is pleased to offer the City of Sanger, CA our proposal for a Valve Assessment and
Exercising program. This program is based on locating, exercising, assessing, and documenting approximately
200 Valves in the City of Sanger’s water distribution system.

2025 Valve Program Fee
Valves Exercised at $3,750.00 daily (Approx. 20 days)

$75,000.00

Report Fee

$ 4,000.00

Mobilization

$16,400.00

Total

$95,400.00

These fees are all based on approximate numbers of valves to be exercised and assessed. The total price will
change according to the actual number of valves completed. All procedures will be followed according to
the above scope of services.
We thank you for this opportunity to introduce our Valve Exercising and Assessment Program and offer
this proposal. If you have further inquiries or would like to discuss our service further, do not hesitate to
call us.

Page 104

Page 105 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

IN WITNESS WHEREOF, the parties hereto have caused this Agreement, the scope and proposal above
for the City of Sanger, CA, to be executed on ________________________________ 2025.

Owner

Service Provider

City of Sanger, CA

M.E. Simpson Company, Inc.

By:

By:
Name: ________________________

Name: Michael D. Simpson

Title: _________________________

Title: Chief Executive Officer

Attest:

Attest:
Name: ________________________

Name: Joe Nepras

Title: _________________________

Title: Regional Manager

Page 105

Page 106 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program

TERMS & CONDITIONS
The following terms and conditions of sale (“Terms”) govern all sales of services, as detailed in this proposal (“Services”) by M.E. Simpson Co.,
Inc. These Terms supersede any prior written or oral agreement, understanding, representation or promise, and any pre-printed or standard
terms and conditions included in Buyer’s request for quote, purchase order, invoice, order acknowledgment or similar document. These Terms
may not be amended or modified, except by concurrent or subsequent written agreement signed by an authorized representative of M.E. Simpson
Co., Inc. and Buyer. M.E. Simpson Co., Inc.’s acknowledgement of Buyer’s purchase order will not constitute acceptance of any terms and
conditions contained therein, regardless of how such terms and conditions may be prefaced or described.
1.

Scope of Work: M.E. Simpson Co., Inc. agrees to conduct a [PROJECT NAME] as outlined in the proposal document, utilizing state-of-theart technologies and experienced personnel to identify and address water losses within the designated water distribution system.
2. Project Timeline: The project timeline provided in the proposal is an estimate and subject to change based on weather conditions, site
accessibility, and unforeseen circumstances. M.E. Simpson Co., Inc. will make reasonable efforts to adhere to the proposed schedule but
cannot guarantee strict adherence.
3. Client Cooperation: The successful completion of the [PROJECT NAME] is contingent upon the full cooperation and support of the client,
including providing access to necessary infrastructure, data, and personnel as requested by M.E. Simpson Co., Inc.
4. Confidentiality: All information and data obtained during the [PROJECT NAME] will be treated as confidential and used solely for the
project. M.E. Simpson Co., Inc. will not disclose any sensitive information to third parties without prior consent from the client.
5. Payment Terms: Payment for services rendered by M.E. Simpson Co., Inc. shall be made by the terms outlined in the proposal document.
Any additional costs incurred due to changes in project scope or unforeseen circumstances shall be agreed upon by both parties in writing
before implementation.
6. Liability: While every effort will be made to minimize risks and ensure the safety of personnel and property during the [PROJECT NAME],
M.E. Simpson Co., Inc. shall not be held liable for any damages, losses, or injuries arising from the performance of the project, except in
cases of proven negligence.
7. Intellectual Property: Any intellectual property rights associated with the findings, reports, or recommendations resulting from the
[PROJECT NAME] shall remain the property of M.E. Simpson Co., Inc. unless otherwise agreed upon in writing.
8. Termination: Either party reserves the right to terminate the agreement upon written notice in case of a material breach by the other
party or if circumstances make it impossible to continue the project.
9. Governing Law: This agreement shall be governed by and construed by the jurisdiction's laws where the project is conducted without
regard to its conflict of law provisions.
10. Amendments: Any amendments or modifications to the terms and conditions of this agreement must be made in writing and signed by
authorized representatives of both parties.

PURCHASE AND SALE
M.E. SIMPSON CO., INC. hereby agrees to deliver Services and Buyer agrees to purchase Services on the terms set forth in the proposal and
subject to these Terms. Subject to the proposal, Buyer may issue M.E. SIMPSON CO., INC. purchase orders for the purchase of Services from M.E.
SIMPSON CO., INC. All purchase orders are subject to acceptance by M.E. SIMPSON CO., INC. and will reference this proposal and agreement and
will describe at a minimum Services being purchased, the purchase price and requested performance date.

PURCHASE PRICE AND TAXES
(a) Price: The price to be paid by Buyer for Services is set forth in this proposal or, if the parties intend to contract using purchase orders, will be
set forth in one or more purchase orders. The purchase price excludes any applicable taxes.
(b) Taxes: M.E. SIMPSON CO., INC.’s price, unless otherwise agreed, will be fixed and does not include, and M.E. SIMPSON CO., INC. is not
responsible for, payment of any tax levied for sales, use, excise, value-added, goods and services, business (franchise or privilege) or any duties,
charges or other such taxes.
(c) Payment Terms: Payment is due within Net 30 days from the invoice delivery date.
(d) Additional Services. The proposed cost of Services, as set forth in this proposal, is provided based on Services outlined in this proposal. Any
work requested by Buyer must reflect the Services and otherwise fall within the terms and the conditions of the proposal. Any requests for
additional services will be invoiced separately.

Page 106

Page 107 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program
(e) Set Off. All amounts that Buyer owes M.E. SIMPSON CO., INC. under an Order will be due and payable according to the terms, state above, of
the Order. Buyer may not set-off such amounts or any portion thereof, whether or not liquidated, against sums that Buyer asserts are due it or
any of its affiliates under other transactions with M.E. SIMPSON CO., INC. or any of its affiliates.

TIMING OF DELIVERY
M.E. SIMPSON CO., INC. will use commercially reasonable efforts to complete the Services within the timeframe, if any, indicated in this proposal.
Actual delivery times may vary, and M.E. SIMPSON CO., INC. will be liable for a delay in delivery only to the extent that M.E. SIMPSON CO., INC.
fails to exercise commercially reasonable efforts in performing the Services. Failure to deliver Services by any mutually agreed date will not be a
sufficient cause for cancellation of this agreement. M.E. SIMPSON CO., INC. will not be liable for delay in delivery due to causes beyond its
reasonable control, including, but not limited to, acts of God, acts of government, acts of Buyer, fires, labor disputes, boycotts, floods, epidemics,
quarantine restrictions, war, insurrection, terrorism, riot, civil or military authority, freight embargos, transportation shortages or delays,
unusually severe weather or inability to obtain necessary labor, materials or manufacturing facilities due to such causes. In the event of any such
delay, the date of delivery will be extended for a length of time equal to the period of the delay.

LIMITATION OF LIABILITY
(a) Consequential Damages: IN NO EVENT WILL M.E. SIMPSON CO., INC. BE LIABLE FOR ANY LOST REVENUE, LOST PROFITS, LOST SAVINGS OR
CONSEQUENTIAL, INCIDENTAL, EXEMPLARY OR PUNITIVE DAMAGES EVEN IF ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES.
(b) Limitation of Direct Damages: IN RESPECT OF ANY CLAIM, DEMAND OR ACTION BY BUYER AGAINST M.E. SIMPSON CO., INC. OR ANY OF ITS
EMPLOYEES, DIRECTORS, OFFICERS, AFFILIATES OR AGENTS (THE “PROTECTED PARTIES”) WHETHER BASED IN CONTRACT, TORT (INCLUDING
NEGLIGENCE), OR OTHERWISE, INCLUDING A BREACH BY M.E. SIMPSON CO., INC. OF ANY OF ITS OBLIGATIONS (WHETHER OR NOT A
FUNDAMENTAL BREACH), BUYER’S EXCLUSIVE REMEDY WILL BE TO RECEIVE FROM M.E. SIMPSON CO., INC. PAYMENT FOR ACTUAL AND DIRECT
DAMAGES TO A MAXIMUM AGGREGATE AMOUNT EQUAL TO THE PURCHASE PRICE PAID BY BUYER TO M.E. SIMPSON CO., INC. FOR THE SERVICES
IN QUESTION.
(c) Asbestos: During the course of delivering Services, M.E. SIMPSON CO., INC. may conduct tests on asbestos cement pipe. Any information
provided to Buyer by M.E. SIMPSON CO., INC. regarding the condition or serviceability of such pipe relates only to its capacity to hold and transport
water. As between the parties, Buyer is solely responsible for complying with all laws and regulations related to asbestos and asbestos cement
pipe. Buyer will protect, indemnify and hold harmless the Protected Parties from and against any and all actions, causes of action, proceedings,
losses, damages, judgments, penalties and expenses that may be imposed on, incurred by or asserted or threatened against the Protected Parties
that are related to asbestos or asbestos cement pipe and M.E. SIMPSON CO., INC.’s performance of this contract.
(d) Buyer agrees to look exclusively to Buyer’s insurer to recover for injuries or damage in the event of any loss or injury and Buyer releases and
waives all right of recovery against M.E. SIMPSON CO., INC. arising by way of subrogation.

INDEMNITY
Buyer agrees to indemnify, hold harmless and defend M.E. SIMPSON CO., INC., and its directors, officers, employees, agents, successors, assigns,
customers, users and those for whom it acts as agent (together, the “Indemnified Parties”) against any and all judgments, losses, damages,
violations, penalties, expenses, costs, including defense costs and legal fees, arising from any and all lawsuits, demands, or claims for personal
injury, death, property damage, or other liability arising or claimed to arise from any act or omission of the Buyer, its agents or its employees that
is related to the performance of this Agreement.

DISCLAIMER
All forms of non-destructive testing involve an inherent and unavoidable level of uncertainty. The results provided by M.E. SIMPSON CO., INC.
are not guaranteed. The methods used are highly dependent on input parameters and provided data; therefore, it is not possible to certify the
results. M.E. SIMPSON CO., INC. is not responsible for any actions taken or recommendations made by Buyer based on the results presented in
the report.

INTELLECTUAL PROPERTY RIGHTS
(a) M.E. SIMPSON CO., INC. owns all right, title and interest in and to the Services, including all components thereof, and all derivative works,
modifications and all Intellectual Property Rights related thereto or derived therefrom. Intellectual Property Rights means all inventions,
processes, business models, methods of doing business, know-how, works of authorship, copy, artwork, designs, software, code, and other
material, and all patents, trademarks, service marks, copyrights, trade secrets, moral rights, and other intellectual property and proprietary rights
therein.

Page 107

Page 108 of 179

M.E. Simpson Co., Inc. | Valve Assessment Program
(b) Each party hereto will keep and own its Intellectual Property Rights existing prior to the Effective Date of this Agreement. Except as expressly
set forth herein, none of the execution, delivery nor performance of this Agreement will be construed as granting or conferring to either party
hereto, or any other third party, any interest, right or license of any kind or nature in or to the other party’s Intellectual Property Rights.
(c) All information, technology, materials and other work, including the Intellectual Property Rights related thereto, conceived, discovered,
developed or created pursuant to this Agreement, alone or in conjunction with a third party (“Project Work”), is and will be owned exclusively by
M.E. SIMPSON CO., INC. Buyer hereby unconditionally and irrevocably transfers and assigns and upon the future creation thereof transfers and
assigns to M.E. SIMPSON CO., INC. all right, title and interest in or to any Project Work. M.E. SIMPSON CO., INC. hereby grants Buyer a worldwide,
non-exclusive, non-transferable, non-sub-licensable, perpetual right to use, copy or modify any report or other deliverable provided by M.E.
SIMPSON CO., INC. in the course of performing the Services. All rights not expressly granted to Buyer under this agreement are expressly reserved
by M.E. SIMPSON CO., INC.
MISCELLANEOUS
(a) These Terms will be binding upon and will inure to the benefit of M.E. SIMPSON CO., INC. and Buyer and their respective successors and
permitted assigns. Buyer will not assign this agreement or its rights or obligations hereunder without the prior written consent of M.E. SIMPSON
CO., INC.
(b) Governing Law; Time Limit to Bring Claims: These Terms will be governed by, and construed and enforced in accordance with, in the case of
M.E. Simpson Co., Inc., the laws in force in the State of Indiana (in each case, excluding any conflict of laws rule or principle which might refer
such construction to the laws of another jurisdiction). The parties agree to submit to the jurisdiction of the courts of the of the State of Indiana,
respectively, and in each case waive any objection relating to improper venue or forum non conveniens to the conduct of any proceeding in any
such court. It is agreed that no suit or cause of action or other proceeding will be brought against either party more than 1 year after accrual of
the cause of action or 1 year after the claim arises, whichever is shorter, whether known or unknown when the claim arises or whether based on
tort, contract or any other legal theory.
(c) Severability: If any portion of these Terms is determined to be illegal, invalid or unenforceable for any reason, then such provision will be
deemed stricken for purposes of the dispute in question and all other provisions will remain in full force and effect.
(d) Waiver: Failure by M.E. SIMPSON CO., INC. to assert all or any of its rights upon any breach of this agreement will not be deemed a waiver of
such rights either with respect to such breach or any subsequent breach, nor will any waiver be implied from the acceptance of any payment of
service. No waiver of any right will extend to or affect any other right M.E. SIMPSON CO., INC. may possess, nor will such waver extend to any
subsequent similar or dissimilar breach.

Page 108

Page 109 of 179

From:
To:
Cc:
Subject:
Date:

Shaffer Fluetsch
Andy Alvarez
George Jasso
RE: Valve King Valve Exercising Program
Wednesday, January 7, 2026 11:24:00 AM

Hi Andy. I hope you had a Merry Christmas and a Happy New Years! Just want to check back in to see
if you have any updates for us. Thank you very much.
From: Shaffer Fluetsch
Sent: Tuesday, December 16, 2025 9:30 AM
To: Andy Alvarez <[email protected]>
Cc: George Jasso <[email protected]>
Subject: RE: Valve King Valve Exercising Program
Hi Andy. Just wanted to check in on your proposal. Please let me know if you have any questions.
Thanks!
From: Shaffer Fluetsch
Sent: Monday, December 1, 2025 3:52 PM
To: Andy Alvarez <[email protected]>
Cc: George Jasso <[email protected]>
Subject: RE: Valve King Valve Exercising Program
Hi Andy. Just want to follow up on your proposal. Thank you!
From: Andy Alvarez <[email protected]>
Sent: Thursday, October 30, 2025 10:23 AM
To: Shaffer Fluetsch <[email protected]>
Subject: Re: Valve King Valve Exercising Program
EXTERNAL EMAIL - This email was sent by a person from outside your organization. Exercise caution when
clicking links, opening attachments or taking further action, before validating its authenticity.

Hello Shaffer,
We are working with our GIS team on getting that quote sent out to you.
Andy Alvarez
VALVE KING inc.
[email protected]
310-493-0046

Page 109

Page 110 of 179

Inline image

On Tue, Oct 28, 2025 at 10:50 AM Shaffer Fluetsch <[email protected]> wrote:

Hi Andy. Just want to reach back out to see if you’ve had a chance to evaluate the data. Thank
you!
From: George Jasso <[email protected]>
Sent: Thursday, October 16, 2025 3:21 PM
To: Shaffer Fluetsch <[email protected]>; Andy Alvarez
<[email protected]>
Subject: Re: Valve King Valve Exercising Program
Nope, You hit all the highlights Shaffer,
George
From: Shaffer Fluetsch <[email protected]>
Sent: Thursday, October 16, 2025 3:12 PM
To: Andy Alvarez <[email protected]>
Cc: George Jasso <[email protected]>
Subject: RE: Valve King Valve Exercising Program

Hi Andy. Attached are the shapefiles we’ve had our GIS staff put together for specific sections in
the city that are of the most concern to us. We have it narrowed down to about 200 valves within
our distribution system that will need addressing. As a reminder, here is the scope of work we are
looking for:

Getting our valves accurately mapped in GIS
Noting the condition of each valve with recommendations if
Verifying shutdowns
Having a corrective action plan put in place once valves have been mapped, exercised, and
shutdowns have been confirmed

George, please let me know if I’m missing anything.

Please let me know if you need anything else in order to review and provide us a quote. Thank you

Page 110

Page 111 of 179

very much!

From: Shaffer Fluetsch
Sent: Friday, October 3, 2025 1:28 PM
To: Andy Alvarez <[email protected]>
Cc: George Jasso <[email protected]>
Subject: RE: Valve King Valve Exercising Program

Hi Andy. Thank you for following up. We are actually mapping the sections of town of most
concern and will be checking with our GIS consultant on creating a file based on those sections for
your review. Once I get some more information, I will let you know.

From: Andy Alvarez <[email protected]>
Sent: Friday, October 3, 2025 12:11 PM
To: Shaffer Fluetsch <[email protected]>
Subject: Re: Valve King Valve Exercising Program

EXTERNAL EMAIL - This email was sent by a person from outside your organization. Exercise caution
when clicking links, opening attachments or taking further action, before validating its authenticity.

Shaffer,

Following up on our meeting. Could we get the GIS database so we can complete our quote?

Thank you,

Andy Alvarez

VALVE KING inc.
[email protected]

Page 111

Page 112 of 179

310-493-0046

On Wed, Sep 17, 2025 at 8:18 AM Shaffer Fluetsch <[email protected]> wrote:

Hi Andy. Yes, it’s set up for 1-2 PM today. It looks like you’ve also accepted the meeting. Thank
you for following up.

From: Andy Alvarez <[email protected]>
Sent: Tuesday, September 16, 2025 7:40 PM
To: Shaffer Fluetsch <[email protected]>
Subject: Re: Valve King Valve Exercising Program

EXTERNAL EMAIL - This email was sent by a person from outside your organization. Exercise caution
when clicking links, opening attachments or taking further action, before validating its authenticity.

Shaffer,

Are you still open this week for a teams call? Both of your emails were sent to my spam for some reason and I
did not see the teams invitation. Sorry for any inconvenience.

Thank you,

Andy Alvarez

VALVE KING inc.
[email protected]

Page 112

Page 113 of 179

310-493-0046

On Thu, Sep 4, 2025 at 2:51 PM Shaffer Fluetsch <[email protected]> wrote:

Hi Andy. I spoke to Russ, and I’ll set up a Teams Meeting for Sept 17 from 1-2 PM. Thank you
all.

From: Shaffer Fluetsch
Sent: Tuesday, September 2, 2025 9:10 AM
To: Andy Alvarez <[email protected]>
Subject: RE: Valve King Valve Exercising Program

Yes, let’s please have a meeting. Would Teams work for you? We are pretty open the week
of September 15. Also, could you resend the quote for review? Thank you very much!

From: Andy Alvarez <[email protected]>
Sent: Friday, August 29, 2025 6:43 PM
To: Shaffer Fluetsch <[email protected]>
Subject: Valve King Valve Exercising Program

EXTERNAL EMAIL - This email was sent by a person from outside your organization. Exercise
caution when clicking links, opening attachments or taking further action, before validating its
authenticity.

Dear Shaffer,

Page 113

Page 114 of 179

My name is Andy Alvarez, and I am with Valve King. I spoke with George last year about implementing a
valve exercising program. At that time, he suggested reaching out before July 1st. I’ve tried contacting him
but haven’t been able to get through. We also sent a quote for valve maintenance last year.

I’d like to discuss this further and explore how we can assist you. Could we schedule a meeting at your
convenience? Please let me know a suitable time.

Thank you for your time and consideration.

Best regards,

Andy Alvarez

Valve King

Andy Alvarez

VALVE KING inc.
[email protected]

310-493-0046

Page 114

Page 115 of 179

For the Meeting of: February 19, 2026
Agenda Item No.: E-9

CITY OF SANGER

REPORT TO THE CITY COUNCIL
To:

Mayor and Councilmembers

From:

Greg Tarascou, Fire Chief

Subject:

Out of State Travel Request

Attachments:

None

CONFLICT OF INTEREST:
None known.
RECOMMENDATION:
That the City Council approves the out of State travel and training for the Fire Department Fire Chief,
Paramedic Liaison Officer and Fire Inspector to attend the ESO Training Academy and Wave
Conference from April 6-10, 2026, in Austin, Texas.
EXECUTIVE SUMMARY:
The ESO Wave Conference is a four-day industry-leading event focused on data-driven emergency
response improvements, bringing together Fire, EMS, hospital and government professionals to learn,
network and shape future operations. This training aligns directly with the Fire Department’s
organizational goals to enhance operational effectiveness, data usage, interoperability, inspection and
compliance processes and community outcomes.
BACKGROUND:
The Fire Department has utilized ESO Solutions as our software platform for nearly a decade. Software
tools such as our electronic patient care reporting software, fire incident documentation, inspections and
prevention documentation, quality improvement and ambulance billing are used by staff daily and
provide for the mandated reporting we are required to do. These informative sessions during the
Prepared by: _Greg Tarascou

_

REVIEW: City Manager: ______
TYPE OF ITEM:

__X_
____
__X_
____
____

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Approved by: _______________________
Finance: _______

City Attorney: ______

COUNCIL ACTION:  APPROVED  DENIED  NO ACTION

____
____
____
____

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 115

Page 116 of 179

conference show how modern data tools and analytics that are currently available can improve
emergency response outcomes, resource deployment, documentation quality and integrated emergency
workflows. Understanding these tools supports data-informed decision making that drives better
community service delivery, performance measurement and appropriate allocation of budgeted dollars.
REASON FOR RECOMMENDATION:
This training and educational event is only offered in Austin. Conferences such as this create long-term
organizational impact by learning how to leverage the available technology to remain forward-thinking and
adaptable, especially in areas such as data analytics, electronic records and maintaining compliance with
Federal and State laws and guidelines.
FISCAL IMPACT:
The total cost to attend this conference including flight, hotel, per diem and conference registration is $3,500
per person. There are sufficient funds to cover the cost of this training within the General Fund and Measure
“R” training budgets.
ALTERNATIVES:
Do not approve the request in which case the staff will not attend the conference.
ACTIONS FOLLOWING APPROVAL:
Upon approval the normal travel and training forms will circulate through the City Manager’s Office.

\\nas1\shared\Forms & Templates

Page 116

Page 117 of 179

For the Meeting of: February 19, 2026
Agenda Item No.: F-1

CITY OF SANGER
REPORT TO THE CITY COUNCIL
To:

Mayor and City Council

From:

Esperanza Rosales, Public Works Director

Subject:

Review and Acceptance of the City of Sanger – Industrial Pretreatment
Program Local Limits Evaluation Report

Attachments:

1) Industrial Pretreatment Program Local Limits Evaluation Report

CONFLICT OF INTEREST
None known.
RECOMMENDATION
Staff recommend that the City Council, by motion, accept the City of Sanger - Industrial Pretreatment
Program Local Limits Evaluation Report conducted by AM Consulting Engineers and authorize the Public
Works Director or designee to submit the report and propose updated local limits to the Regional Water
Quality Control Board for review and approval.
EXECUTIVE SUMMARY
The City of Sanger contracted AM Consulting Engineers to conduct a comprehensive local limit study.
This study was federally and state mandated to update the City’s outdated industrial discharge limits
ensuring that industrial pollutants do not interfere with the treatment process, cause the City to violate its
Waste Discharge Requirements (WDRs), or contaminate biosolids.

Prepared by:

Esperanza Rosales____

REVIEW: City Manager: ______
TYPE OF ITEM:
ACTION

____
____
_X__
_X__
____

Consent
Info Item
Action Item
Department Report
Redevelopment Agency

Approved by: __Esperanza Rosales_________________
Finance: _______

City Attorney: ______

COUNCIL ACTION:  APPROVED  DENIED  NO

____
____
____
____

Public Hearing
Matter Initiated by a Council Member
Other
Continued to: __________

Page 117

Page 118 of 179

BACKGROUND
The City of Sanger contracted with AM Consulting Engineers to conduct a comprehensive local limit
study. The City of Sanger operates two separate wastewater treatment facilities:

Domestic WWTF: Operating under Waste Discharge Requirements (WDR) R5-2014-0004.
Industrial WWTF: Operating under Waste Discharge Requirements (WDR) 98-131

The City’s Industrial Pretreatment Program is mandated by federal and state regulations (40CFR 403) to
ensure industries do not discharge pollutants that could:


Interfere with the Wastewater Treatment Facility treatment processes.
Cause the City to violate its WDR permit limits or water quality standards.
Contaminate biosolids (sludge) or impact public health and safety.

Local Limits
Local Limits are specific pollutant concentration limits set by the City for industrial discharges into the
sanitary sewer system. They are the primary tool used to protect the treatment facilities, the environment,
and public health. The City’s previous local limits were outdated. This comprehensive study was
required and conducted using current monitoring data and US Environmental Protection Agency (EPA)
guidance to update them.
Study Objectives
The Study was performed with the following key objectives:


Evaluate Existing Conditions: Assess current wastewater pollutant loading at both the Domestic
and the Industrial Treatment Facilities.
Determine Capacity: Establish available treatment capacity based on current WDR design criteria.
Update Pollutant Limits: Develop new industrial discharge limits that:
o Protect each facilities treatment performance.
o Maintain compliance with state and federal regulations.
o Preserve capacity for future industrial and residential growth.

Development of Local Limits
The development process involved two distinct phases:
Phase I: Evaluation of WDR-Based Local Limit
This phase focused on pollutants regulated by the City’s current WDRs.

Domestic WWTF Evaluation: The analysis centered on Biochemical Oxygen Demand (BOD),
Total Suspended Solids (TSS), and Electrical Conductivity (EC). Recent sampling data from the
plant and collection system were used to partition the load between residential and industrial
sources. The findings were compared against the facility’s design capacity to confirm available
capacity and develop updated industrial limits that remain within WDR compliance.
Industrial WWTF Evaluation: A similar approach was used, comparing monitoring data to the
facility’s design flow and treatment capacity, particularly focusing on the strength of wastewater
from major industries.
Page 118

Page 119 of 179

Phase II: Evaluation of Local Limits Using EPA Guidance
This phase applied the U.S. EPA’s Local Limits Development Guidance (2004) to evaluate additional
Pollutants of Concern that may affect: treatment performance, biosolid quality, and receiving water
quality. The process involved:



Identifying Pollutants of Concern not directly regulated by the WDR’s (e.g metals).
Determining pollutant removal efficiency at each facility.
Calculating Maximum Allowable Headworks Loadings (MAHLs) the highest pollutant load that
can enter the facility without causing interference or environmental harm.
Using the most conservative MAHL results to recommend protective local limits.

Proposed Local Limits
The study recommends the following updated local limits for both the Domestic and Industrial WWTF’s,
derived from the WDR, facility design data, and EPA guidance:
Comparison of Existing and Proposed Local Limits
Industrial WWTF
Pollutant

Existing Local
Limit(1)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium

Domestic WWTF

Proposed
Local Limit

Required
Local Limit

Proposed
Local Limit

Required
Local Limit

1.0 mg/L
0.7 mg/L
1.0 mg/L
1.0 mg/L
1.0 mg/L
0.4 mg/L
0.01 mg/L
1.0 mg/L
0.7 mg/L
1.0 mg/L
None
2.0 mg/L

0.012 mg/L
0.006 mg/L
0.05 mg/L
0.058 mg/L
0.015 mg/L
0.006 mg/L
0.002 mg/L
0.081 mg/L
0.00 mg/L
0.343 mg/L
0.024 mg/L
0.009 mg/L

No
No
No
Yes
Yes
Yes
No
No
No
Yes
No
Yes

0.22 mg/L
0.11 mg/L
0.93 mg/L
0.03 mg/L
0.25 mg/L
0.07 mg/L
0.03 mg/L
1.53 mg/L
0.00 mg/L
2.71 mg/L
0.45 mg/L
0.04 mg/L

No
No
No
Yes
No
No
No
No
No
Yes
No
Yes

BOD5

300 mg/L

Total Suspended Solids
Ammonia
EC
pH
FOG

300 mg/L
0.32 mg/L
700 µmhos/cm
6.5 – 8.5
100 mg/L

1,000 mg/L
600mg/L
27 mg/L
700 µmhos/cm
6.0 – 9.0
100 mg/L

Yes
Yes
No
Yes
Yes
Yes

500 mg/L
500 mg/L
327 mg/L
1,000 µmhos/cm
6.0 – 9.0
100 mg/L

Yes
Yes
Yes
Yes
Yes
Yes

Note:
(1)
Existing Local Limit are detailed in Section 82-175 of the City of Sanger's Municipal Code and pertain to
both the Industrial and Domestic WWTFs.

Page 119

Page 120 of 179

The proposed limits are essential for several key reasons: they are necessary to protect each facility’s
treatment performance and long-term reliability, required to maintain compliance with regulatory
requirements, serve to fairly allocate capacity between residential and industrial users, and preserve
sufficient treatment capacity for future growth.
Outreach and Industry Engagement
The Public Works Department conducted a series of meetings with affected industries to present the draft
Local Limits Evaluation Study. These meetings were collaborative and productive; staff addressed
technical questions regarding the proposed new limits, and industry representatives were provided with
the opportunity to discuss potential operational impacts.
Electrical Conductivity (EC) Limit Exemptions for Dischargers
One of the City’s primary industries communicated that they would be unable to meet the newly proposed
Electrical Conductivity (EC) limits based on their current operations. In response, the City sought further
guidance from the Regional Water Quality Control Board.
The Regional Board determined that the City is exempt from strictly enforcing the EC limits on individual
dischargers provided that the City remains an active participant in the Central Valley Salinity Alternatives
for Long Term Sustainability (CV-SALTS) coalition. CV-SALTS is a collaborative initiative developed
to manage salt and nitrates in the Central Valley to ensure long-term water quality and economic
sustainability.
Under this program, the City must ensure that these industries maintain their current discharge quality,
provided these levels do not worsen. This specific exemption and the requirement to maintain current EC
discharge quality will be formally documented in the respective user discharge permit.
REASON FOR RECOMMENDATION
To establish Implementation Plan (Regulatory Submittal and Ordinance Amendment) to ensure legal
compliance, financial responsibility, and infrastructure longevity.
FISCAL IMPACT
Acceptance is a crucial step in sound fiscal stewardship, primarily generating benefits through cost
avoidance of penalties associated with regulatory non-compliance and long-term asset protection.
ALTERNATIVES
Do not accept the report and provide staff with further direction, although not recommended.
ACTIONS FOLLOWING APPROVAL
The Public Works Department will submit the Local Limit Evaluation Report to the Regional Water
Quality Control Board for approval and subsequently prepare the necessary ordinance amendments.

Page 120

Page 121 of 179

ATTACHMENT 1

Page 121

Page 122 of 179

CITY OF SANGER

INDUSTRIAL PRETREATMENT PROGRAM
LOCAL LIMITS EVALUATION
DRAFT
October 2025

Prepared by:

AM Consulting Engineers, Inc. − 5150 N Sixth Street, Suite 124 − Fresno, CA 93711 − P: 559.473.1371 − F: 559.513.8449

Page 122

Page 123 of 179

City of Sanger
Local Limits Study
Table of Contents

TABLE OF CONTENTS
SECTION 1 - INTRODUCTION ......................................................................................................................... 2
1.1.

Need for Local Limits..................................................................................................................... 2

1.2.

Facility Description ........................................................................................................................ 2

1.2.1.

Domestic Wastewater Treatment Facility ............................................................................ 3

1.2.2.

Industrial Wastewater Treatment Facility ............................................................................ 3

1.3.

Industrial Dischargers ................................................................................................................... 4

SECTION 2 - LOCAL LIMIT DEVELOPMENT .................................................................................................... 5
2.1.

Pollutants of Concern.................................................................................................................... 5

2.2.

EPA POCs ....................................................................................................................................... 5

2.3.

Waste Discharge Requirements POCs .......................................................................................... 6

2.4.

Other Reasons for POCs ................................................................................................................ 7

2.4.1.

Water Quality Criteria ........................................................................................................... 7

2.4.2.

Biosolids Land Application Criteria ....................................................................................... 7

2.4.3.

Interference and Inhibition Criteria ...................................................................................... 7

2.4.4.

Protection of Treatment Works, Collection System, and Workers....................................... 8

SECTION 3 - DEVELOPMENT OF LOCAL DISCHARGE LIMITS ......................................................................... 9
3.1.

Evaluation of WDR-Based Local Limits.......................................................................................... 9

3.1.1.

Domestic WWTF Local Limit Development........................................................................... 9

3.1.2.

Industrial WWTF Local Limit Development ........................................................................ 11

3.2.

Evaluation of Local Limits Using EPA Guidance .......................................................................... 13

3.2.1.

WWTF Removal Efficiencies ................................................................................................ 14

3.2.2.

Allowable Headworks Loadings .......................................................................................... 15

3.2.3.

Maximum Allowable Headworks Loadings ......................................................................... 25

3.2.4.

Designating Local Limits ...................................................................................................... 27

3.2.5.

Background Loadings for Non-Industrial Sources ............................................................... 28

3.2.6.

Maximum Allowable Industrial Loadings ............................................................................ 29

3.2.7.

Local Limits Allocation......................................................................................................... 32

3.2.8.

Industrial WWTF – Evaluation of Local Limits ..................................................................... 32

ii

Page 123

Page 124 of 179

City of Sanger
Local Limits Study
Table of Contents

3.2.9.

Domestic WWTF – Evaluation of Local Limits ..................................................................... 33

SECTION 4 - Proposed Local Limits ............................................................................................................. 35
4.1.

Comparison of Existing and Proposed Limits .............................................................................. 35

4.2.

Recommended Action and Conclusion ....................................................................................... 36

APPENDIX A RESIDENTIAL BACKGROUND SAMPLING

LIST OF TABLES
Table 2-1 EPA POCs ....................................................................................................................................... 5
Table 2-2 Domestic WWTF WDRs POCs........................................................................................................ 6
Table 3-1 Evaluation of Current Values ........................................................................................................ 9
Table 3-2 Domestic WWTF Design Loadings and Allocations ..................................................................... 10
Table 3-3 Domestic WWTF Proposed Industrial Local Limits and Spare Capacity...................................... 11
Table 3-4 Industrial WWTF Current Influent Conditions (2024) ................................................................. 12
Table 3-5 Industrial WWTF Design, 2024 Influent Loadings, and Spare Capacity ...................................... 12
Table 3-6 Industrial WWTF Proposed Industrial Local Limits and Spare Capacity...................................... 13
Table 3-7 Summary of Removal Efficiencies ............................................................................................... 14
Table 3-8 Industrial WWTF – Water Quality Standard AHLs ...................................................................... 17
Table 3-9 Domestic WWTF – Water Quality Standard AHLs....................................................................... 18
Table 3-10 Industrial WWTF – Summary of Water Quality Standard AHLs ................................................ 19
Table 3-11 Domestic WWTF – Summary of Water Quality Standard AHLs ................................................ 19
Table 3-12 Industrial WWTF – Summary of Biosolids Disposal Based AHLs ............................................... 21
Table 3-13 Domestic WWTF – Summary of Biosolids Disposal Based AHLs ............................................... 22
Table 3-14 Industrial WWTF – Activated Sludge and Nitrification Inhibition Based AHLs ......................... 23
Table 3-15 Domestic WWTF – Activated Sludge and Nitrification Inhibition Based AHLs ......................... 24
Table 3-16 Industrial WWTF – Summary Inhibition Based AHLs ................................................................ 24
Table 3-17 Domestic WWTF – Summary Inhibition Based AHLs ................................................................ 25
Table 3-18 Industrial WWTF – Maximum Allowable Headworks Loadings ................................................ 25
Table 3-19 Domestic WWTF – Maximum Allowable Headworks Loadings ................................................ 26
Table 3-20 Industrial WWTF - Comparison of MAHLs with Average Headworks Loadings ........................ 27
Table 3-21 Domestic WWTF - Comparison of MAHLs with Average Headworks Loadings ........................ 27
Table 3-22 Estimated Background Loadings from Non-Industrial Sources ................................................ 29

iii

Page 124

Page 125 of 179

City of Sanger
Local Limits Study
Table of Contents

Table 3-23 Industrial WWTF – Maximum Allowable Industrial Loadings ................................................... 30
Table 3-24 Domestic WWTF – Maximum Allowable Industrial Loadings ................................................... 31
Table 3-25 Industrial WWTF – Uniform Allocation of Local Limits ............................................................. 33
Table 3-26 Domestic WWTF – Uniform Allocation of Local Limits ............................................................. 33
Table 4-1 Comparison of Existing and Proposed Local Limits..................................................................... 35

iv

Page 125

Page 126 of 179

City of Sanger
Local Limits Study
Abbreviation

ABBREVIATIONS
AHL
ACGIH

Allowable Headworks Loading
American Conference of Governmental Industrial Hygienists

BOD

Biochemical Oxygen Demand

EC
EPA

Electrical Conductivity
Environmental Protection Agency

HDPE

High-Density Polyethylene

MAHL
µmhos/cm
MGD
mg/L

Maximum Allowable Headworks Loading
Micromhos per Centimeter
Million Gallons per Day
Milligram per Liter

NIOSH

National Institute for Occupational Safety and Health

OSHA

Occupational Health and Safety Administration

lbs/day
PWTW

Pounds per Day
Publicly Owned Treatment Works

SIU

Significant Industrial User

TSS

Total Suspended Solids

VOC

Volatile Organic Compound

WDR
WWTF

Waste Discharge Requirements
Wastewater Treatment Facility

v

Page 126

Page 127 of 179

City of Sanger
Local Limits Study
Section 1 – Introduction

SECTION 1 - INTRODUCTION
1.1.

Need for Local Limits

Publicly Owned Treatment Works (POTWs) serve a crucial role in regulating the type and volume of
pollutants introduced into municipal wastewater systems. These regulations are essential for protecting
treatment facilities from operational disruptions, preventing the pass-through of contaminants,
maintaining water quality in the underlining groundwater and receiving streams, preserving sludge
integrity, and ensuring worker safety. Additionally, POTWs must effectively manage conventional
pollutants to maintain compliance with permit limits while ensuring the long-term efficiency of their
systems.
To regulate the discharge of toxic and conventional pollutants from non-domestic sources, POTWs
establish and enforce Pretreatment Standards, commonly referred to as local limits. The U.S.
Environmental Protection Agency (EPA) outlines the recommended approach for developing these limits
in its Local Limits Development Guidance (2004).
The City of Sanger (City) owns and operates two separate wastewater treatment facilities (WWTFs): a
Domestic WWTF and Industrial WWTF. These facilities serve residential, commercial, and industrial users
within the City’s service area and are located on adjacent properties southeast of the City limits. Each
WWTF operates with independent collection, treatment, and disposal systems and is regulated under
separate Waste Discharge Requirements (WDRs) issued by the Central Valley Regional Water Quality
Control Board.
This Local Limits Study was prepared to evaluate and establish pollutant discharge limitations for both the
City of Sanger’s Domestic and Industrial WWTFs. The purpose of the Study is to ensure that non-domestic
discharges do not interfere with the performance of the WWTF’s, hinder the safe disposal or reuse of
biosolids, or cause violations of the effluent limitations and groundwater protection requirements
specified in the respective WDRs. Accordingly, this Study evaluates discharge limits for each facility based
on its design capacity to treat specific pollutants such as biochemical oxygen demand (BOD), total
suspended solids (TSS), electrical conductivity (EC), and fats, oils, and grease (FOG). Where facility-specific
design limits are not defined for a pollutant, local discharge limits are established using procedures
outlined in the U.S. Environmental Protection Agency’s Local Limits Development Guidance (July 2004).

1.2.

Facility Description

The City of Sanger operates two separate WWTFs, each serving different segments of the community’s
wastewater system. These facilities are regulated under distinct WDRs and differ in their treatment
processes, effluent disposal methods, and the nature of incoming wastewater. The following subsections
provide detailed overviews of each facility, including design capacity, key infrastructure, operational
practices, and influent characteristics. This foundational information supports the evaluation of pollutant
loadings and the development of technically appropriate local limits specific to each facility’s
configuration and regulatory obligations.

2

Page 127

Page 128 of 179

City of Sanger
Local Limits Study
Section 1 – Introduction

1.2.1. Domestic Wastewater Treatment Facility
The Domestic WWTF is regulated under Waste Discharge Requirements (WDR) Order No. R5-2014-0004.
The facility includes a headworks with a grit chamber, two primary clarifiers, an activated sludge unit,
secondary clarifiers, a sludge thickener, an anaerobic digester, a Dissolved Air Flotation (DAF) unit,
centrifuge, and a sludge holding tank. Although a disinfection system is installed, it is not currently in
operation. Treated effluent is conveyed through a 20-inch PVC pipeline to the Lincoln Ponds, a 120-acre
City-owned property with six percolation ponds. Each pond covers approximately nine acres, providing a
combined storage capacity of 328 acre-feet. Three ponds are actively used for effluent disposal, while the
remaining two are reserved for emergency use. The WWTF is designed to treat an average dry-weather
flow of 3.0 million gallons per day (MGD). From 2021 through 2024, the facility treated an average influent
flow of approximately 1.67 MGD.
Per WDR Order No. R5-2014-0004, the design influent average annual BOD and TSS concentrations are
224 mg/L and 226 mg/L, corresponding to 5,604 pounds per day (lbs/day) and 5,655 lbs/day, respectively.
In comparison, influent data collected in 2024 indicated an average annual flow of 1.80 MGD, with BOD
and TSS concentrations of 243 mg/L and 272 mg/L, representing loadings of 3,649 lbs/day and 4,079
lbs/day. The average EC concentration in 2024 was 777 µmhos/cm, equating to approximately 11,651
lbs/day. Under the WDR, the maximum allowable EC in the discharge may not exceed the weighted
average of the source water plus 500 µmhos/cm. Based on monitoring of the City’s ten groundwater
supply wells, the weighted average EC of the source water was 281 µmhos/cm, establishing a discharge
limit of 781 µmhos/cm.
The Domestic WWTF primarily receives wastewater from residential and commercial sources within the
City, along with contributions from four industrial users: Initiative Foods (private-label baby food
manufacturer), International Paper (corrugated packaging producer), Pitman Family Farms (chicken
hatchery), and GBI USA Co. (pet treat manufacturer. While none of these users currently meet the
definition of a Significant Industrial User (SIU), their discharges may contain pollutants that affect
treatment performance or effluent quality. Accordingly, this Study evaluates the combined contributions
of industrial and non-industrial sources to determine whether local limits are necessary for specific POCs.
1.2.2. Industrial Wastewater Treatment Facility
The Industrial WWTF operates under WDR Order No. 98-131 and is designed to treat up to 1.3 MGD of
wastewater generated primarily by Pitman Farms and Gibson Winery. From 2021 through 2024, the
WWTF received an average influent flow of approximately 0.842 MGD, with a 30-day maximum daily
average of approximately 1.07 MGD.
The treatment process includes headworks with dual aerated grit chambers, three mechanically aerated
treatment ponds, one aerated storage pond, and three non-aerated storage ponds. The treatment ponds
are lined with soil cement, and the storage ponds are lined with synthetic liners to minimize percolation.
Treated effluent is applied to 116 acres of adjacent farmland via flood or furrow irrigation at agronomic
rates. The facility also has provisions to utilize a shared clarifier and filter system, operated in coordination
with the Domestic WWTF, for additional treatment when necessary. Sludge that accumulates in the

3

Page 128

Page 129 of 179

City of Sanger
Local Limits Study
Section 1 – Introduction

treatment ponds is removed at the discretion of a local grower and land-applied for agricultural purposes
on City-owned reclamation fields. The City does not oversee sludge removal or application activities but
conducts mid-year monitoring to assess solids accumulation levels.
Consistent with the Domestic WWTF, WDR Order No. 98-131 specifies that influent EC shall not exceed
the weighted average EC of the source water plus 500 µmhos/cm. Based on monitoring of the City’s
groundwater supply wells, this establishes an influent EC limit of 781 µmhos/cm. Unlike the Domestic
WWTF, the Industrial WWTF’s WDR does not prescribe numeric effluent limitations for BOD or TSS.
Instead, design values identified in a 1995 Black & Veatch memorandum specify maximum month daily
average concentrations of 3,360 mg/L BOD and 760 mg/L TSS, corresponding to 36,429 lbs/day and 8,240
lbs/day, respectively. By comparison, influent monitoring conducted in 2024 indicated a 30-day maximum
daily average flow of 0.993 MGD, with average BOD and TSS concentrations of 1,160 mg/L. The average
EC influent concentration in 2024 was 1,015 µmhos/cm, equivalent to approximately 8,403 lbs/day.
The Industrial WWTF exclusively receives wastewater from Pitman Farms and Gibson Winery, both of
which have been designated by the City as SIUs. Their discharges contain elevated levels of BOD, TSS, and
EC that can significantly affect treatment performance and effluent quality. Accordingly, this Study
evaluates pollutant contributions from these SIUs relative to facility design capacity and regulatory
requirements to determine whether local limits are warranted for POCs.

1.3.

Industrial Dischargers

The City of Sanger provides sewer service to residential, commercial, and industrial users within its service
area. A dedicated industrial sewer system conveys wastewater exclusively from two SIUs: Gibson Winery
and Pitman Farms. Gibson Winery, a producer of table and dessert wines, discharges primarily during the
grape crush season, with peak flows typically occurring between August and October. Pitman Farms, a
poultry processing facility, generates wastewater on a relatively consistent basis unlike Gibson Winery.
The volume, strength, and variability of these industrial discharges have the potential to introduce
elevated pollutant loadings, particularly BOD, TSS, EC and FOG, that may impact treatment performance,
regulatory compliance, and the ability to manage biosolids in accordance with state and federal standards.
For these reasons, a careful evaluation of pollutant contributions from both SIUs is critical to protecting
the Industrial WWTF.
The Domestic WWTF, in contrast, receives flows from residential neighborhoods, commercial
establishments, and several small-scale industrial sources, as detailed in Section 1.2.1. Although the
industrial users are currently not designated by the City as SIUs, their discharges can still affect treatment
plant performance by influencing operational efficiency, effluent quality, and compliance with WDR Order
No. R5-2014-0004.
To address these potential impacts, this Study evaluates pollutant loading from both industrial and nonindustrial sources to determine whether local limits are necessary at each facility. The following sections
outlines the methodology used to identify and assess POCs. This evaluation establishes the technical
foundation for developing defensible local limits that protect the treatment capacity and operational
integrity of both WWTFs, ensure ongoing compliance with applicable WDRs, and safeguard public health,
water quality, and the environment.

4

Page 129

Page 130 of 179

City of Sanger
Local Limits Study
Section 2 – Pollutants of Concern

SECTION 2 - LOCAL LIMIT DEVELOPMENT
2.1.

Pollutants of Concern

The development of local limits is critical to ensuring the efficient operation of the publicly owned
treatment works (POTW), protecting worker health and safety, preventing the discharge of harmful
pollutants into the environment, and maintaining the quality of treated sludge. These limits also play a
key role in ensuring compliance with discharge permits and aligning with federal, state, and local
regulatory requirements. To achieve these goals, it is essential to identify and regulate POCs that have the
potential to disrupt wastewater treatment processes, compromise effluent quality, or pose
environmental and public health risks.
POCs are pollutants that require monitoring and control to safeguard the wastewater treatment facility,
its operators, the integrity of the collection system, and the proper disposal of treated effluent and
biosolids. These pollutants can contribute to pass-through contamination, interfere with treatment
processes, damage infrastructure, or affect a facility’s ability to manage and dispose of biosolids in
compliance with environmental standards.
The following sections outline the criteria for determining whether a pollutant should be classified as a
POC. While multiple factors may justify the inclusion of a pollutant on this list, its designation as a POC
does not necessarily mean that a local limit must be established. The need for local limits is evaluated in
Section 4, where a thorough assessment is conducted. If a pollutant is identified as a POC, data collection
and a detailed analysis must be carried out to determine the appropriate regulatory and treatment
measures needed to mitigate its impact.

2.2.

EPA POCs

The EPA has designated 15 key pollutants that are commonly present in wastewater treatment plant
effluent and biosolids. These pollutants are classified as POCs due to their potential to impact treatment
processes, effluent quality, and biosolid management. As part of any local limits evaluation, these
pollutants must be assessed to determine their potential risks and the need for regulatory controls. A
comprehensive list of these pollutants is provided in Table 2-1.
Table 2-1 EPA POCs
Pollutant
Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
5

Page 130

Page 131 of 179

City of Sanger
Local Limits Study
Section 2 – Pollutants of Concern

Table 2-1 EPA POCs
Pollutant
Selenium
BOD5
Total Suspended Solids (TSS)
Ammonia

2.3.

Waste Discharge Requirements POCs

While federally regulated pollutants remain a primary focus, both the Domestic and Industrial WWTFs are
also subject to locally established pollutant control measures that account for site-specific regulatory
requirements and environmental conditions. For the Domestic WWTF, WDR Order No. R5-2014-0004
establishes effluent limitations and monitoring requirements for discharges to the onsite effluent disposal
ponds. Pollutants with enforceable effluent limits under the WDR are therefore designated as POCs for
this Study. Table 2-2 presents these POCs and the corresponding most stringent effluent limitations
established by the WDR.
Table 2-2 Domestic WWTF WDRs POCs
Pollutant

Discharge Limitation

BOD5 (mg/L)

40

TSS (mg/L)

40

EC

1,000 umhos/cm or source
water plus 500 umhos/cm,
whichever is less

As detailed in Section 1.2.1, WDR Order No. R5-2014-0004 also defines design influent loading criteria of
224 mg/L BOD and 226 mg/L TSS, which correspond to 5,604 lbs/day and 5,655 lbs/day, respectively, at
the facility’s design flow of 3.0 MGD. These design concentrations provide the technical basis for
evaluating headworks loadings and will be applied in this Study to determine appropriate local limits for
the Domestic WWTF.
Similar to the Domestic WWTF, the Industrial WWTF is also regulated under WDR Order No. 98-131 with
a discharge limitation for EC, which may not exceed the weighted average EC of the source water plus 500
µmhos/cm. Based on 2024 monitoring of the City’s ten groundwater supply wells, the weighted average
EC of the source water was 281 µmhos/cm, resulting in an effluent EC limit of 781 µmhos/cm for both the
Domestic and Industrial WWTFs.
Unlike the Domestic WWTF, WDR Order No. 98-131 does not prescribe numeric effluent limitations for
BOD or TSS at the Industrial WWTF. Instead, design values identified in a 1995 Black & Veatch
Memorandum provide the most appropriate benchmarks for local limits development. These design
criteria specify maximum month daily average influent concentrations of 3,360 mg/L BOD and 760 mg/L
TSS. At the design flow of 1.3 MGD, these concentrations correspond to loadings of 20,760 lbs/day BOD
and 4,686 lbs/day TSS. Accordingly, this Study applies the maximum month daily average concentrations
for BOD and TSS, in conjunction with the facility’s design flow, to establish applicable local limits for the
Industrial WWTF.

6

Page 131

Page 132 of 179

City of Sanger
Local Limits Study
Section 2 – Pollutants of Concern

2.4.

Other Reasons for POCs

In addition to pollutants identified by federal and state regulations, certain pollutants may be classified as
POCs due to their potential to impact wastewater treatment operations, environmental quality, or
regulatory compliance. The evaluation of these additional POCs ensures that the City of Sanger’s
wastewater treatment facilities can effectively manage both municipal and industrial discharges while
maintaining compliance with their respective WDRs and other applicable regulatory standards.
2.4.1. Water Quality Criteria
One key factor in determining POCs is water quality criteria. Effluent from the WWTF is discharged into
evaporation/percolation ponds, and any pollutants present in significant concentrations may affect
groundwater quality and environmental health. Pollutants with the potential to exceed water quality
objectives or contribute to groundwater contamination must be evaluated to determine whether they
require local limits.
2.4.2. Biosolids Land Application Criteria
Sludge and biosolids generated at the City of Sanger’s wastewater treatment facilities are managed in
compliance with applicable state and federal regulations to ensure safe handling, disposal, and protection
of public health and the environment. At the Domestic WWTF, sludge is periodically removed from
treatment units to maintain operational efficiency and is either disposed of at a permitted landfill, landapplied, or processed through other approved reuse methods. These activities are conducted in
accordance with WDR Order No. R5-2014-0004, Title 40 CFR Part 503, and relevant California regulations.
Management of sludge within the treatment and storage ponds is performed by a local grower, who
removes and land-applies the material on City-owned reclamation fields for beneficial reuse on a periodic
basis. The City does not perform or direct these activities but conducts mid-year inspections to evaluate
solids buildup and maintain compliance with operational requirements.
To maintain compliance, both WWTFs must prevent the discharge of industrial pollutants that could
compromise sludge quality or result in violations of applicable disposal regulations. The national standards
under 40 CFR Part 503 establish pollutant concentration limits, operational standards, management
practices, and requirements for sampling, recordkeeping, and reporting. These standards are designed to
mitigate risks to human health and the environment associated with biosolids use or disposal.
The State of California has adopted the federal 40 CFR Part 503 standards and imposes additional land
application restrictions under Title 22 of the California Code of Regulations. As such, pollutants regulated
under these frameworks are evaluated as POCs to ensure biosolids generated at the WWTFs remain
compliant with all applicable state and federal criteria for safe disposal or land application.
2.4.3. Interference and Inhibition Criteria
The EPA’s pretreatment regulations outlined in 40 CFR 403.5(a) require the prohibition of industrial
discharges that could cause interference at the WWTF’s. According to the EPA, interference occurs when
a discharge inhibits or disrupts the treatment process, resulting in a violation of the WWTF’s WDRs or
biosolids disposal requirements. To prevent such disruptions, the EPA recommends that pollutants with a
history of causing interference be classified as POCs.
Although some pollutants may not lead to effluent violations or biosolids disposal issues, they can still
negatively impact WWTF operations by disrupting biological treatment processes or affecting overall
7

Page 132

Page 133 of 179

City of Sanger
Local Limits Study
Section 2 – Pollutants of Concern

system performance. The EPA Local Limits Development Guidance provides information on pollutants that
have inhibition concentrations for various treatment plant processes. Identifying and monitoring these
pollutants is essential to ensuring that influent characteristics remain within acceptable operational
thresholds, thereby preventing disruptions to treatment efficiency and regulatory compliance.
2.4.4. Protection of Treatment Works, Collection System, and Workers
Explosive and flammable pollutants pose a significant risk to the integrity of the sewer collection system
and the health and safety of WWTF workers. Under certain conditions, the accumulation of these
substances can lead to fires or explosions, endangering facility operations and personnel. If industrial
users are expected to discharge such pollutants, establishing local limits may be necessary to mitigate
these risks and ensure safe system operation.
In addition to combustion hazards, fume toxicity levels of specific pollutants can have severe health
implications for WWTF workers. Volatile organic compound (VOC) vapors are of particular concern, as
they may be toxic, carcinogenic, and capable of causing chronic health effects after prolonged or repeated
exposure. The EPA’s Local Limits Development Guidance outlines concentration thresholds for hazardous
airborne contaminants based on standards set by the National Institute for Occupational Safety and
Health (NIOSH), Occupational Health and Safety Administration (OSHA), and American Conference of
Governmental Industrial Hygienists (ACGIH). If industrial discharges contain these pollutants at levels that
could endanger workers, local limits may be required to protect both worker safety and treatment facility
operations.

8

Page 133

Page 134 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

SECTION 3 - DEVELOPMENT OF LOCAL DISCHARGE LIMITS
After identifying POCs for the Domestic and Industrial WWTFs (Tables 2-1 and 2-2) and compiling
necessary sampling data, local discharge limits can be established for each facility. For pollutants directly
regulated by the applicable WDRs, including BOD, TSS, and EC, local limits are based on the facility’s design
capacity and effluent limitations specified in the WDRs. For pollutants without defined facility-specific
design values, local limits are developed in accordance with the U.S. Environmental Protection Agency’s
Local Limits Development Guidance, ensuring consistent protection of treatment capacity, effluent
quality, and receiving environments.

3.1.

Evaluation of WDR-Based Local Limits

The following section evaluates the local limits for the Domestic and Industrial WWTFs that are specifically
derived from their WDRs, focusing on BOD, TSS, and EC as the key regulated parameters.
3.1.1. Domestic WWTF Local Limit Development
For the Domestic WWTF, the local limits for BOD, TSS, and EC were derived directly from the design criteria
established in WDR Order No. R5-2014-0004. Table 3-1 presents the evaluation of current values using
2024 influent monitoring data, domestic sampling data collected from lift stations, and the average daily
flow contributed by industrial users discharging to the facility. These calculations provide a breakdown of
pollutant contributions between domestic and industrial sources.
Table 3-1 Evaluation of Current Values
2024 Domestic WWTF Influent
Conc.
Flow
Loading
(mg/L,
(MGD)
(lbs/day)
µmhos/cm)

Domestic Influent
Industrial Influent Calculated
Conc.
Conc.
Flow
Loading
Flow
Loading
(mg/L,
(mg/L,
(MGD)
(lbs/day) (MGD)
(lbs/day)
µmhos/cm)
µmhos/cm)

BOD5

1.80

243

3,649

1.71

205

2,921

0.089

984

728

Total Suspended
Solids

1.80

272

4,079

1.71

209

2,973

0.089

1,495

1,106

EC

1.80

777

11,651

1.71

724

10,320

0.089

1,798

1,331

Pollutant

At the average influent flow of 1.80 MGD, the WWTF received wastewater with an average BOD
concentration of 243 mg/L, a TSS concentration of 272 mg/L, and an EC of 777 µmhos/cm in 2024. While
the City’s Domestic WWTF primarily treats wastewater from residential and commercial sources, the
facility also receives flows from four permitted industrial users. According to the City, the combined
average daily discharge from these industries is 0.089 MGD. Subtracting this amount from the total
influent flow yields a domestic flow of 1.71 MGD.
To characterize domestic contributions, the City collected composite samples at two lift stations that do
not receive any industrial flows. The average concentrations from those sampling locations, shown in
Table 3-1, represent the domestic influent values used in this evaluation. Industrial contributions for BOD,
TSS, and EC were then calculated by subtracting the domestic influent loadings (expressed in lbs/day)
from the total WWTF influent loadings. This approach provides an estimate of the pollutant loadings
attributable to industrial discharges, ensuring that the resulting local limits reflect both actual operating
conditions and the design basis of the facility.
9

Page 134

Page 135 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

The Domestic WWTF is designed to treat an average daily flow of 3.0 MGD with design influent
concentrations of 224 mg/L BOD, 226 mg/L TSS, and 781 µmhos/cm EC. At 3.0 MGD, these concentrations
correspond to design loadings of 5,604 lbs/day BOD, 5,655 lbs/day TSS, and 19,533 lbs/day EC. Given that
the current domestic flow is approximately 1.71 MGD, the City projects domestic flows will increase by
about 35 percent, reaching approximately 2.63 MGD at buildout. The remaining portion of the 3.0 MGD
design flow, approximately 0.37 MGD, is therefore allocated to industrial users.
Table 3-2 presents the corresponding design loadings for BOD, TSS, and EC, along with the estimated
division of capacity between residential and industrial sources.
Table 3-2 Domestic WWTF Design Loadings and Allocations

Pollutant

BOD5

Flow
(MGD)
3
3
3

Domestic WWTF Design
WWTF
Concentration
Residential
Total
(mg/L,
Loading
Loading
µmhos/cm)
(lbs/day)(1)
(lbs/day)
4,494
224
5,604

Industrial
Loading
(lbs./day)(2)
1,111

Total Suspended Solids
4,574
1,081
226
5,655
781
15,877
3,656
EC
19,533
Notes:
(1)
Residential Loading values were calculated by applying the current pollutant concentrations
(Table 3-1) to the estimated residential flow capacity of 2.63 MGD.
(2)
Industrial Loading values represent the remaining portion of the total WWTF design loading,
determined as the difference between the WWTF Total Loading and the Residential Loading.
Using the estimated design flow rate and loadings allocated to industrial users determined in Table 3-2,
the appropriate local limits for BOD, TSS, and EC at the Domestic WWTF can now be established. Table 33 presents the proposed industrial local limits and the corresponding spare design capacity. Spare capacity
represents the remaining industrial loading available after applying the proposed limits and was calculated
by subtracting the proposed industrial loading (expressed in lbs/day at 0.089 MGD) from the total
industrial allocation defined by the facility’s design capacity. For example, the Domestic WWTF is designed
to accommodate 1,111 lbs/day of industrial BOD. At the proposed local limit of 500 mg/L and an industrial
flow of 0.089 MGD, existing users would contribute approximately 370 lbs/day, leaving 741 lbs/day
unused capacity. This margin ensures that the facility can absorb fluctuations in industrial loading and still
remain within design specifications. The same calculation was applied to TSS and EC, yielding spare
capacities of 711 lbs/day and 2,916 lbs/day, at the proposed limit of 500 mg/L and 1,000 µmhos/cm,
respectively.

10

Page 135

Page 136 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-3 Domestic WWTF Proposed Industrial Local Limits and Spare Capacity
Available Design
Spare Design
Proposed Local Limit
Capacity
Capacity
Industrial
Pollutant
Industrial Industrial Industrial
Industrial Industrial Industrial
Concentration
Flow
Loading
Flow
Loading
Flow
Loading
(mg/L,
(MGD)
(lbs/day)
(MGD)
(lbs/day)
(MGD)
(lbs/day)
µmhos/cm)
BOD5

0.37

1,111

0.089

500

370

0.178

741

Total Suspended Solids
EC

0.37
0.37

1,081
3,656

0.089
0.089

500
1000

370
740

0.170
0.350

711
2,916

In addition to pollutant-specific spare capacity, the proposed limits allow the City to accept approximately
0.170 MGD of additional industrial flow, nearly double the current industrial contribution of 0.089 MGD.
This demonstrates that the proposed limits not only protect the WWTF’s treatment performance and
compliance with WDR Order No. R5-2014-0004 but also preserves sufficient capacity to accommodate
reasonable future industrial growth.
The proposed local limits are ultimately consistent with the WWTF’s WDRs and design capacity, keeping
industrial discharges within the established treatment and disposal capabilities of the Domestic WWTF.
The concentrations proposed for BOD, TSS, and EC are achievable for industrial users, while also providing
a conservative margin that protects the facility’s biological treatment processes, compliance with effluent
limitations, and long-term operational reliability. In addition, maintaining a substantial portion of the
industrial allocation as spare design capacity preserves flexibility for existing and future industrial
contributors and reduces the risk of noncompliance. Together, these factors ensure that the proposed
limits balance operational protection, regulatory requirements, and equitable allocation of treatment
capacity between residential and industrial users.
3.1.2. Industrial WWTF Local Limit Development
For the Industrial WWTF, design criteria for BOD, TSS, and EC are derived from WDR Order No. 98-131
and the 1995 Black & Veatch design memorandum, which establishes the governing design flow and
loading capacities used in developing proposed local limits. The facility is designed to treat an average
daily flow of 1.3 MGD. According to records from 2021 to 2024, the WWTF received an average influent
flow of 0.842 MGD, while the 30-day maximum daily average reached approximately 1.07 MGD. In 2024,
the 30-day maximum daily average was 0.993 MGD. Wastewater discharges from Pitman Farms are
relatively consistent, while discharges from Gibson Winery are seasonal and vary with production cycles.
Accordingly, the evaluation of proposed local limits is based on the 30-day maximum daily average rather
than the overall average daily flow.
Table 3-4 summarizes influent monitoring data for the Industrial WWTF during 2024. At a 30-day
maximum daily average flow of 0.993 MGD, wastewater received from Pitman Farms and Gibson Winery
contained an average BOD concentration of 1,160 mg/L, equivalent to 9,606 lbs/day. TSS average 477
mg/L, or 3,951 lbs/day, while EC average 1,015 µmhos/cm, corresponding to 8,403 lbs/day. These values
establish the WWTF’s current operating conditions and provide the basis for comparison with the facility’s
design capacity.

11

Page 136

Page 137 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-4 Industrial WWTF Current Influent Conditions (2024)
Concentration
Flow
Loading
Pollutant
(mg/L,
(MGD)
(lbs/day)
µmhos/cm)
BOD5

0.993

1,160

Total Suspended Solids
EC

0.993
0.993

477
1,015

9,606
3,951
8,403

As previously stated, WDR Order No. 98-131 does not prescribe numeric effluent limitations for BOD or
TSS. Instead, design values from the 1995 Black & Veatch memorandum establish maximum month daily
average concentrations of 3,360 mg/L BOD₅ and 760 mg/L TSS, equivalent to 36,429 lbs/day and 8,240
lbs/day, respectively, at the design flow of 1.3 MGD. For EC, WDR Order No. 98-131 specifies that influent
shall not exceed the weighted average EC of the source water plus 500 µmhos/cm. Based on groundwater
monitoring of the City’s supply wells, this requirement translates to an influent EC limit of 781 µmhos/cm,
or 8,468 lbs/day.
Table 3-5 compares these design flow and loading capacities with actual influent monitoring data
collected in 2024. The difference between the design allocation and observed loadings defines the
available spare capacity for each pollutant. Results show substantial reserves for BOD (26,823 lbs/day)
and TSS (4,289 lbs/day), but a minimal margin for EC (64 lbs/day). This comparison demonstrates that
while the facility can accommodate additional organic and solids loadings, EC is operating near its design
threshold and therefore requires more careful management in establishing local limits.
Table 3-5 Industrial WWTF Design, 2024 Influent Loadings, and Spare Capacity
WWTF Design
Pollutant

Flow
(MGD)

WWTF Influent (2024 Data)

Concentration
Loading
(mg/L,
(lbs/day)
µmhos/cm)

Flow
(MGD)

Concentration lbs/day
(mg/L,
Loading
µmhos/cm)
(lbs/day)

Spare
Capacity
(lbs/day)

BOD5

0.993
1,160
9,606
26,823
1.3
3,360
36,429
Total Suspended Solids
0.993
477
3,951
4,289
1.3
760
8,240
0.993
1,015
8,403
64
EC
1.3
781
8,468
Table 3-6 outlines the proposed industrial local limits for BOD, TSS, and EC at the Industrial WWTF. The
proposed limits are expressed as concentrations at the full design flow of 1.3 MGD and translated to
equivalent mass loadings in lbs/day. The spare design capacity shown represents the remaining pollutant
loading that the facility could accept beyond the proposed limits, thereby maintaining a margin of safety
for variability in industrial discharges and potential future growth.

12

Page 137

Page 138 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-6 Industrial WWTF Proposed Industrial Local Limits and Spare Capacity
WWTF Design

Proposed Local Limit

Spare Design Capacity

Flow
(MGD)

Loading
(lbs/day)

Flow
(MGD)

Conc.
(mg/L,
µmhos/cm)

Loading
(lbs/day)

Flow
(MGD)

Loading
(lbs/day)

BOD5

1.30

36,429

1.30

1,000

10,842

3.07

25,587

Total Suspended Solids

1.30

8,240

1.30

600

6,505

0.35

1,735

EC

1.30

8,468

1.30

700

7,589

0.15

878

Pollutant

As shown, the proposed limits preserve substantial spare capacity for BOD (25,587 lbs/day) and TSS (1,735
lbs/day), ensuring that the facility can continue to accommodate increases in organic and solids loadings
without exceeding design parameters. However, the margin for EC is more limited (878 lbs/day),
highlighting the need for careful monitoring and management of salinity to maintain compliance with
WDR Order No. 98-131 In terms of flow, the most restrictive spare capacity is associated with EC, which
allows for an additional 0.15 MGD of industrial discharge. This value represents the maximum additional
flow the facility can reliably accept without surpassing its design allocation for EC. Collectively, these
proposed limits align with the facility’s design criteria and protect treatment performance.

3.2.

Evaluation of Local Limits Using EPA Guidance

While the previous section focused on pollutants regulated under the Domestic and Industrial WWTF’s
WDRs, this approach does not address all pollutants that may impair treatment plant operations, biosolids
quality, or affect downstream water quality. To establish comprehensive and defensible local limits, this
Study also applies the U.S. Environmental Protection Agency’s Local Limits Development Guidance.
Under this methodology, treatment plant removal efficiencies are quantified and evaluated alongside
factors such as water quality standards, biosolids disposal requirements, and process inhibition
thresholds. These evaluations are used to calculate Maximum Allowable Headworks Loadings (MAHLs),
which represent the maximum pollutant loading that can be introduced to a WWTF without causing passthrough, interference, or violations of applicable regulatory standards. The following procedures are used
to establish MAHLs for each POC at the Domestic and Industrial WWTFs:
1. Determine the WWTF-specific removal efficiencies for each POC, based on representative influent
and effluent data;
2. Calculate the Allowable Headworks Loadings (AHLs) using environmental criteria applicable to
each facility, such as Waste Discharge Requirements (WDRs), water quality standards, biosolids
disposal limits, and biological inhibition thresholds;
3. Identify the MAHL as the lowest (most conservative) of the calculated AHLs to ensure adequate
protection of treatment processes, receiving waters, sludge management practices, and worker
safety.
This section presents the application of the EPA guidance to the City’s Domestic and Industrial WWTFs.
The results provide the technical foundation for determining whether additional local limits are warranted
beyond those imposed by WDRs and ensure that industrial discharges are protective of public health,
water quality, and the long-term operational integrity of the City’s treatment facilities.

13

Page 138

Page 139 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

3.2.1. WWTF Removal Efficiencies
At both the Domestic and Industrial WWTFs, POCs are monitored to evaluate treatment performance and
demonstrate compliance with regulatory requirements. At the Industrial WWTF, monitoring focuses on
EC and BOD because of their significance to salinity management and organic loading strength. At the
Domestic WWTF, monitoring also includes TSS, as required by the facility’s WDRs. As discussed in Section
3.1, BOD, TSS, and EC have already been evaluated under applicable WDRs and the facility’s design
capacity and are not reassessed here under the EPA methodology.
At the Domestic WWTF, ammonia is also a POC that is routinely monitored, and sufficient site-specific
data are available to calculate removal efficiency. However, aside from ammonia, the City does not collect
paired influent and effluent data for the other POCs identified in Table 2-1. In these cases, pollutant
removal efficiencies were assigned using the default values provided in Appendix R of the U.S. EPA’s Local
Limits Development Guidance. These default values represent typical removal rates for activated sludge
systems and are widely recognized as appropriate for developing technically defensible local limits.
By incorporating both site-specific data where available and EPA-recommended default values where data
are lacking, the City can calculate MAHLs for each POC in a manner consistent with federal guidance, while
ensuring protection of treatment processes, biosolids quality, and receiving water standards. Table 3-7
summarizes the pollutant removal efficiencies applied for both the Domestic and Industrial WWTFs.
Table 3-7 Summary of Removal Efficiencies
Industrial WWTF
Domestic WWTF
POCs
Removal
Removal
Efficiency
Efficiency
Arsenic(1)

45%

45%

(1)

67%

67%

(1)

Cadmium

Chromium
Copper

82%

82%

(1)

86%

86%

(1)

69%

69%

61%

61%

Cyanide
(1)

Lead

Mercury

(1)

60%

60%

(1)

42%

42%

(1)

75%

75%

79%

79%

63%

63%

50%

50%
34%

Nickel
Silver
Zinc

(1)
(1)

Molybdenum
Selenium

(1)
(2)

Ammonia
0%
Notes:
(1)
Priority pollutant percent removal efficiencies through activated
sludge treatment as recommended by the 2004 USEPA Local Limits
Guidance.

14

Page 139

Page 140 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-7 Summary of Removal Efficiencies
Industrial WWTF
Domestic WWTF
POCs
Removal
Removal
Efficiency
Efficiency
(2)
For the Industrial WWTF, no effluent data results available to
calculate removal efficiency.
3.2.2. Allowable Headworks Loadings
After quantifying pollutant removal efficiencies for the Domestic and Industrial WWTFs, the next step in
the local limits development process is to calculate AHLs. AHLs represent the maximum pollutant loadings
that can be introduced to a treatment facility without causing pass-through, interference, or violations of
applicable environmental criteria. These criteria include state and federal water quality standards, sludge
disposal limitations, and biological process inhibition thresholds. By evaluating AHLs for POC, the City can
determine the level of influent loading that each facility can reliably accept while ensuring protection of
groundwater quality, biosolids management, and treatment system performance. The following
subsections present the calculated AHLs for both facilities, categorized by water quality, sludge disposal,
and inhibition-based criteria.
3.2.2.1. Water Quality Standard
For POCs without enforceable permit limits, the U.S. EPA’s Local Limits Development Guidance
recommends calculating AHLs using state or federal water quality standards. These standards may be
based on aquatic life protection criteria for both acute (short-term) and chronic (long-term) exposure, or
on human health protection criteria such as drinking water consumption, recreational use, or fish
ingestion.
Although the WDRs for both the Domestic and Industrial WWTFs do not authorize surface water
discharges, they require that all discharges remain protective of underlying groundwater basin, as this
groundwater is designated for municipal and domestic supply, agricultural supply, and industrial service
supply. Accordingly, in developing local limits, the water quality standards applied must be consistent with
these designated beneficial uses. For POCs with applicable water quality criteria, AHLs are calculated using
the methodology presented in Equation 1.
Equation 1 – AHL based on Water Quality limits:

AHL𝑊𝑄 =

(8.34)[(𝐶𝑊𝑄 ) ∗ (𝑄𝑆𝑇𝑅+ 𝑄𝑊𝑊𝑇𝐹 ) − (𝐶𝑆𝑇𝑅 ∗ 𝑄𝑆𝑇𝑅 )]
1 − 𝑅𝑊𝑊𝑇𝑃

Where:
AHLWQ = AHL based on water quality criteria, lb/day
CWQ = State or Federal water quality standard, mg/L
CSTR = Receiving stream background concentration, mg/L
QWWTF = WWTF average flow rate, MGD
QSTR = Receiving stream (upstream) flow rate, MGD

15

Page 140

Page 141 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

RWWTF = Plant removal efficiency, as decimal
8.34 = Conversion factor
Using Equation 1, the individual chronic, acute, agricultural, and human health AHLs for each pollutant
have been consolidated into a single summary table for each facility, presented in Tables 3-8 and 3-9.

16

Page 141

Page 142 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-8 Industrial WWTF – Water Quality Standard AHLs

Pollutant

WWTF
Flow
(MGD)
(QWWTF)

Water Quality Standard (mg/L) (CWQ)
Allowable Headworks Loading (lbs/day)
Receiving Receiving
Stream
Stream
Removal
Flow
Conc.
Efficiency
Human
Human
Chronic(1) Acute(1) Agricultural(2)
Chronic Acute Agricultural
(1)
(MGD)
(mg/L)
(R
)
WWTF
Health
Health
(QSTR)
(CSTR)

Arsenic
0.71
0
0.01
0.15
0.34
0.1
0.01
45%
1.628
3.691
1.086
0.109
Cadmium
0.71
0
0.00
0.0022
0.0043
0.01
0.005
67%
0.039
0.077
0.179
0.090
Chromium
0.71
0
0.00
0.01
0.016
0.1
0.01
82%
0.362
0.526
3.290
0.329
Copper
0.71
0
0.23
0.009
0.013
0.2
1.3
86%
0.381
0.550
8.460
54.987
Cyanide
0.71
0
0.00
0.0052
0.022
0.15
69%
0.099
0.420
2.865
Lead
0.71
0
0.03
0.0025
0.065
5
0.015
61%
0.038
0.987
75.919
0.228
Mercury
0.71
0
0.00
0.00077 0.0014
0.002
60%
0.011
0.021
0.030
Nickel
0.71
0
0.01
0.052
0.47
0.2
0.1
42%
0.531
4.799
2.042
1.021
Silver
0.71
0
0.00
0.0034
75%
0.081
Zinc
0.71
0
0.24
0.12
0.12
2
79%
3.384
3.384
56.397
Molybdenum
0.71
0
0.003
0.01
63%
0.160
Selenium
0.71
0
0.01
0.005
0.02
0.05
50%
0.059
0.237
0.592
Ammonia
0.71
0
5.70
30
0%
177.650
Notes:
(1)
National Recommended Water Quality Criteria for Priority Pollutants as reported in Appendix D of the EPA Local Limits Development Guidance.
(2)
California water quality-based assessment thresholds published by the State Water Resources Control Board at the following website:
www.waterboards.ca.gov/water_issues/programs/water_quality_goals.

17

Page 142

Page 143 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-9 Domestic WWTF – Water Quality Standard AHLs

Pollutant

WWTF
Flow
(MGD)
(QWWTF)

Water Quality Standard (mg/L) (CWQ)
Allowable Headworks Loading (lbs/day)
Receiving Receiving
Stream
Stream
Removal
Flow
Conc.
Efficiency
Human
Human
Chronic(1) Acute(1) Agricultural(2)
Chronic Acute Agricultural
(3)
(MGD)
(mg/L)
(R
)
Health
WWTF
Health
(QSTR)
(CSTR)

Arsenic
1.80
0
0.003
0.15
0.34
0.1
0.01
45%
4.122
9.342
2.748
0.275
Cadmium
1.80
0
0.000
0.0022
0.0043
0.01
0.005
67%
0.100
0.195
0.454
0.227
Chromium
1.80
0
0.005
0.01
0.016
0.1
0.01
82%
0.916
1.332
8.327
0.833
Copper
1.80
0
0.059
0.009
0.013
0.2
1.3
86%
0.964
1.392
21.413
139.183
Cyanide
1.80
0
0.003
0.0052
0.022
0.15
69%
0.251
1.064
7.253
Lead
1.80
0
0.002
0.0025
0.065
5
0.015
61%
0.096
2.498
192.165
0.576
Mercury
1.80
0
0.000
0.00077 0.0014
0.002
60%
0.029
0.052
0.075
Nickel
1.80
0
0.005
0.052
0.47
0.2
0.1
42%
1.344 12.146
5.169
2.584
Silver
1.80
0
0.003
0.0034
75%
0.204
Zinc
1.80
0
0.229
0.12
0.12
2
79%
8.565
8.565
142.751
Molybdenum
1.80
0
0.003
0.01
63%
0.405
Selenium
1.80
0
0.007
0.005
0.02
0.05
50%
0.150
0.600
1.499
Ammonia
1.80
0
832.86
30
34%
677.643
Notes:
(1)
National Recommended Water Quality Criteria for Priority Pollutants as reported in Appendix D of the EPA Local Limits Development Guidance.
(2)
California water quality-based assessment thresholds published by the State Water Resources Control Board at the following website:
www.waterboards.ca.gov/water_issues/programs/water_quality_goals.

18

Page 143

Page 144 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-10 presents the summary of water quality-based AHLs for the Industrial WWTF. The most
restrictive (i.e., lowest) calculated AHL for each POC is selected as the final AHL to ensure protection of
water quality objectives.
Table 3-10 Industrial WWTF – Summary of Water Quality Standard AHLs

Pollutant

Allowable
Headworks
(Chronic)
(lbs/day)

Allowable
Headworks
(Acute)
(lbs/day)

Allowable
Headworks
(Agricultural)
(lbs/day)

Allowable
Headworks
(Human Health)
(lbs/day)

Allowable
Headworks
(Water Quality)
(lbs/day)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

1.63
0.04
0.36
0.38
0.10
0.04
0.01
0.53
3.38
0.06
-

3.69
0.08
0.53
0.55
0.42
0.99
0.02
4.80
0.08
3.38
-

1.09
0.18
3.29
8.46
75.92
2.04
56.40
0.16
0.24
-

0.11
0.09
0.33
54.99
2.87
0.23
0.03
1.02
0.59
177.65

0.11
0.04
0.33
0.38
0.10
0.04
0.01
0.53
0.08
3.38
0.16
0.06
177.65

Table 3-11 presents the summary of water quality-based AHLs for Domestic WWTF. As with the Industrial
WWTF, the most conservative AHL value for each POC is identified and selected to maintain compliance
with applicable water quality standards.
Table 3-11 Domestic WWTF – Summary of Water Quality Standard AHLs

Pollutant

Allowable
Headworks
(Chronic)
(lbs/day)

Allowable
Headworks
(Acute)
(lbs/day)

Allowable
Headworks
(Agricultural)
(lbs/day)

Allowable
Headworks
(Human Health)
(lbs/day)

Allowable
Headworks
(Water Quality)
(lbs/day)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver

4.12
0.10
0.92
0.96
0.25
0.10
0.03
1.34
-

9.34
0.20
1.33
1.39
1.06
2.50
0.05
12.15
0.20

2.75
0.45
8.33
21.41
192.17
5.17
-

0.27
0.23
0.83
139.18
7.25
0.58
0.07
2.58
-

0.27
0.10
0.83
0.96
0.25
0.10
0.03
1.34
0.20

19

Page 144

Page 145 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-11 Domestic WWTF – Summary of Water Quality Standard AHLs

Pollutant

Allowable
Headworks
(Chronic)
(lbs/day)

Allowable
Headworks
(Acute)
(lbs/day)

Allowable
Headworks
(Agricultural)
(lbs/day)

Allowable
Headworks
(Human Health)
(lbs/day)

Allowable
Headworks
(Water Quality)
(lbs/day)

Zinc
Molybdenum
Selenium
Ammonia

8.57
0.15
-

8.57
-

142.75
0.41
0.60
-

1.50
677.64

8.57
0.41
0.15
677.64

According to WDR Order No. 98-131, biosolids generated at the Industrial WWTF are to be managed onsite. Sludge that accumulates in the treatment and storage ponds is removed at the discretion of a local
grower and land-applied for agricultural purposes on City-owned reclamation fields, consistent with Title
27 of the California Code of Regulations and with the Regional Water Quality Control Board approval. The
City does not oversee sludge removal or application activities but conducts mid-year monitoring to assess
solids accumulation levels.
At the Domestic WWTF, as specified in WDR Order No. R5-2014-0004, biosolids are managed through a
mechanical dewatering process. Sludge is thickened and dewatered using a centrifuge, then further dried
in 14 lined, paved drying beds equipped with underdrains. The underdrains return collected decant to the
treatment process for additional treatment. Once dried, biosolids are temporarily stored in a holding bin
prior to being hauled offsite for land application at a permitted facility, while screenings and grit from the
headworks are transported to a local landfill. Under current operations, solids removed from the Industrial
WWTF primary clarifier are conveyed to the Domestic WWTF drying beds for dewatering, while settled
solids within the Industrial treatment and storage ponds are managed separately by a local grower for
land application on City-owned reclamation fields.
Federal regulations for sludge disposal (40 CFR Part 503) continue to apply, establishing limits on metals
and other pollutants that may be present in biosolids due to industrial contributions. For local limits
development, these regulatory thresholds are translated into AHLs for POCs using Equation 2, which is
based on Equation 5.9 from the EPA’s 2004 Local Limits Development Guidance manual. This ensures that
the combined biosolids generated by both WWTFs remain suitable for land application and compliant
with all applicable state and federal requirements.
Equation 2 – AHL based on Sludge Land Application and Surface Disposal:

AHL𝑆𝐿𝐷𝐺 =

(0.0022)(𝐶𝐵𝑆𝑂𝐿 )(𝑄𝐵𝑆𝑂𝐿 )
𝑅𝑊𝑊𝑇𝑃

Where:
AHLSLDG = AHL based on sludge, lb/day
C BSOL = Biosolids limitation, mg/kg dry sludge
Q BSOL = Total sludge flow to disposal, dry metric tons per day
RWWTF = Plant removal efficiency, as decimal
20

Page 145

Page 146 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

GSLDG = Specific gravity of sludge, kg/L
0.0022 = Conversion factor
For Equation 2, QBSOL represents the total sludge flow to disposal in dry metric tons per day. In this study,
QBSOL is estimated from the daily BOD removed at each facility and then converted to dry metric tons per
day. The formula for estimating BOD removal is based on calculating the difference between the influent
and effluent organic loads entering and leaving the treatment facility. First, the influent and effluent BOD
concentrations, measured in milligrams per liter, are converted to mass loadings in pounds per day using
the standard conversion factor of 8.34, multiplied by the plant flow in MGD. The amount of BOD removed
is then determined by subtracting the effluent load from the influent load, with the result representing
the daily mass of BOD reduced through treatment. To translate this value into an estimate of sludge
production, the pounds of BOD removed are converted to dry metric tons per day by dividing by 2,204.62.
Table 3-12 presents the biosolids disposal based AHLs for the Industrial WWTF.
Table 3-12 Industrial WWTF – Summary of Biosolids Disposal Based AHLs
Pollutant

Sludge Flow
to Disposal
(MTD) (QBSOL)

Land Application
Standard
(mg/kg) (CBSOL)(1)

Removal
Efficiency
(RWWTF)

Allowable
Headworks
(lbs/day)

Arsenic
0.39
41
45%
0.08
Cadmium
0.39
39
67%
0.05
Chromium
0.39
82%
Copper
0.39
1500
86%
1.49
Cyanide
0.39
69%
Lead
0.39
300
61%
0.42
Mercury
0.39
17
60%
0.02
Nickel
0.39
420
42%
0.86
Silver
0.39
75%
Zinc
0.39
79%
Molybdenum
0.39
63%
Selenium
0.39
100
50%
0.17
Ammonia
0.39
0%
Notes:
(1)
Based on Title 40 of the Code of Federal Regulations (CFR) Part 503 Table 3 of
Section 503.13
Table 3-13 presents the biosolids disposal–based AHLs for the Domestic WWTF. In 2024, operational
issues at the facility resulted in effluent BOD values exceeding influent levels, making the data unsuitable
for solids estimation. Accordingly, the calculation of QBSOL is based on 2023 influent and effluent BOD and
flow data, which provided more reliable results.

21

Page 146

Page 147 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-13 Domestic WWTF – Summary of Biosolids Disposal Based AHLs
Pollutant

Sludge Flow
to Disposal
(MTD) (QBSOL)

Land Application
Standard
(mg/kg) (CBSOL)(1)

Removal
Efficiency
(RWWTF)

Allowable
Headworks
(lbs/day)

Arsenic
1.19
41
45%
0.24
Cadmium
1.19
39
67%
0.15
Chromium
1.19
82%
Copper
1.19
1500
86%
4.58
Cyanide
1.19
69%
Lead
1.19
300
61%
1.29
Mercury
1.19
17
60%
0.07
Nickel
1.19
420
42%
2.63
Silver
1.19
75%
Zinc
1.19
79%
Molybdenum
1.19
63%
Selenium
1.19
100
50%
0.53
Ammonia
1.19
34%
Notes:
(1)
Based on Title 40 of the Code of Federal Regulations (CFR) Part 503 Table 3 of
Section 503.13
3.2.2.2. Inhibition Based AHLs
Elevated concentrations of specific pollutants in wastewater or sludge can adversely impact the
performance of biological treatment processes typically employed at wastewater treatment facilities.
Both the Industrial and Domestic WWTFs rely on activated sludge systems that are particularly sensitive
to inhibitory substances. Although there have been no documented operational upsets at either facility
attributed to inhibitory pollutants, the potential for such impacts warrants a conservative approach.
Therefore, inhibition-based AHLs are calculated as a preventive measure to safeguard treatment
performance.
In accordance with the U.S. EPA’s Local Limits Development Guidance, inhibition threshold values are used
in estimating AHLs for pollutants of concern. These values are derived from literature-based inhibition
concentrations and are applied using Equation 3 from the EPA guidance. The calculations incorporate
relevant removal efficiencies and site-specific influent data. The corresponding threshold values are
included in Appendix G of the EPA guidance. By incorporating inhibition-based AHLs, the City ensures that
local limits remain technically defensible and protective of both facilities’ biological treatment systems.
Equation 3 – AHL based on Activated Sludge Inhibition Values:

AHL𝐴𝐶𝑇 =

(8.34)(𝐶𝐴𝐶𝑇 )(𝑄𝑊𝑊𝑇𝐹 )
1 − 𝑅𝑊𝑊𝑇𝑃

Where:

22

Page 147

Page 148 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

AHLACT = AHL based on activated sludge inhibition, lb/day
CACT = Inhibition or nitrification criterion for activated sludge, mg/L (EPA Local Limits
Development Guidance, Appendix G)
QWWTF = WWTF average flow rate, MGD
RWWTF = Plant removal efficiency, as decimal
8.34 = Conversion factor
Table 3-14 presents the calculated AHLs for the Industrial WWTF, based on inhibition thresholds for
activated sludge and nitrification processes.
Table 3-14 Industrial WWTF – Activated Sludge and Nitrification Inhibition Based AHLs

Pollutant

WWTF
Flow
(MGD)
(QWWTF)

Inhibition Level
Activated
Sludge
Nitrification
(mg/L)
(mg/L) (CCRIT)(2)
(CACT)(1)
0.1
1.5
1
5.2
1
0.25
1
0.05
0.1
0.34
1
0.5
0.1
0.25
0.3
0.08
480
-

Allowable Headworks
Removal
Efficiency
(RWWTF)

Activated
Sludge
(lbs/day)

Nitrification
(lbs/day)

Arsenic
0.710
45%
1.09
16.28
Cadmium
0.710
67%
17.94
93.31
Chromium
0.710
82%
32.90
8.22
Copper
0.710
86%
42.30
2.11
Cyanide
0.710
69%
1.91
6.49
Lead
0.710
61%
15.18
7.59
Mercury
0.710
60%
1.48
Nickel
0.710
42%
2.55
Silver
0.710
75%
Zinc
0.710
79%
8.46
2.26
Molybdenum
0.710
63%
Selenium
0.710
50%
Ammonia
0.710
0%
2,842.39
Notes:
(1)
Based on the reported range of Activated Sludge Inhibition Threshold Levels as reported in Appendix G of
the EPA Local Limits Development Guidance.
(2)
Based on the reported range of Nitrification Inhibition Threshold Levels as reported in Appendix G of the
EPA Local Limits Development Guidance.
Table 3-15 presents the calculated AHLs for the Domestic WWTF, derived using inhibition thresholds for
activated sludge and nitrification processes, consistent with the methodology applied for the Industrial
WWTF in Table 3-14.

23

Page 148

Page 149 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-15 Domestic WWTF – Activated Sludge and Nitrification Inhibition Based AHLs

Pollutant

WWTF
Flow
(MGD)
(QWWTF)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80
1.80

Inhibition Level
Activated
Nitrification
Sludge
(mg/L)
(mg/L)
(2)
(CCRIT)
(CACT)(1)
0.1
1.5
1
5.2
1
0.25
1
0.05
0.1
0.34
1
0.5
0.1
0.25
0.3
0.08
480
-

Allowable Headworks
Removal
Efficiency
(RWWTF)
45%
67%
82%
86%
69%
61%
60%
42%
75%
79%
63%
50%
34%

Activated
Sludge
(lbs/day)

Nitrification
(lbs/day)

2.75
45.42
83.27
107.06
4.84
38.43
3.75
21.41
10,842.28

41.22
236.19
20.82
5.35
16.44
19.22
6.46
5.71
-

Notes:
(1)
Based on the reported range of Activated Sludge Inhibition Threshold Levels as reported in Appendix G of
the EPA Local Limits Development Guidance.
(2)
Based on the reported range of Nitrification Inhibition Threshold Levels as reported in Appendix G of the
EPA Local Limits Development Guidance.
Table 3-16 summarizes the inhibition-based AHLs calculated for the Industrial WWTF, with the most
restrictive (i.e., lowest) loading identified for each POC.
Table 3-16 Industrial WWTF – Summary Inhibition Based AHLs
Pollutant
Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel

Allowable
Headworks
(Activated Sludge)
(lbs/day)
1.09
17.94
32.90
42.30
1.91
15.18
1.48
-

Allowable Headworks
(Nitrification) (lbs/day)

Most Stringent
Inhibition/AHL
(lbs/day)

16.28
93.31
8.22
2.11
6.49
7.59
2.55

1.09
17.94
8.22
2.11
1.91
7.59
1.48
2.55

24

Page 149

Page 150 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Silver
Zinc
Molybdenum
Selenium
Ammonia

8.46
2,842.39

2.26
-

0.00
2.26
2,842.39

Table 3-17 presents a summary of the inhibition-based AHLs for the Domestic WWTF, highlighting the
lowest allowable loading selected for each POC.
Table 3-17 Domestic WWTF – Summary Inhibition Based AHLs
Pollutant
Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

Allowable
Headworks
(Activated Sludge)
(lbs/day)
2.75
45.42
83.27
107.06
4.84
38.43
3.75
21.41
10,842.28

Allowable Headworks
(Nitrification) (lbs/day)

Most Stringent
Inhibition/AHL
(lbs/day)

41.22
236.19
20.82
5.35
16.44
19.22
6.46
5.71
-

2.75
45.42
20.82
5.35
4.84
19.22
3.75
6.46
0.00
5.71
10,842.28

3.2.3. Maximum Allowable Headworks Loadings
The MAHL for each POC is defined as the most conservative, or lowest, value among the calculated AHLs
derived from applicable environmental and treatment-based criteria. These criteria include water quality
standards, sludge disposal regulations, and process inhibition thresholds. By maintaining influent loadings
below the MAHL, the treatment facilities can ensure compliance with all relevant regulatory and
operational requirements. Table 3-18 summarizes the AHLs evaluated for each POC and identifies the
corresponding MAHL selected for the Industrial WWTF.
Table 3-18 Industrial WWTF – Maximum Allowable Headworks Loadings

Pollutant

Allowable
Headworks (Water
Quality) (lbs/day)

Allowable
Headworks (Sludge)
(lbs/day)

Allowable
Headworks
(Inhibition)
(lbs/day)

Maximum
Allowable
Headworks
(lbs/day)

Arsenic

0.11

0.08

1.09

0.08

25

Page 150

Page 151 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-18 Industrial WWTF – Maximum Allowable Headworks Loadings

Pollutant

Allowable
Headworks (Water
Quality) (lbs/day)

Allowable
Headworks (Sludge)
(lbs/day)

Allowable
Headworks
(Inhibition)
(lbs/day)

Maximum
Allowable
Headworks
(lbs/day)

Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.04
0.33
0.38
0.10
0.04
0.01
0.53
0.08
3.38
0.16
0.06
177.65

0.05
1.49
0.42
0.02
0.86
0.17
-

17.94
8.22
2.11
1.91
7.59
1.48
2.55
0.00
2.26
2842.39

0.04
0.33
0.38
0.10
0.04
0.01
0.53
0.00
2.26
0.16
0.06
177.65

Table 3-19 summarizes the calculated AHLs for each POC at the Domestic WWTF and identifies the
corresponding MAHL based on the most conservative applicable criteria.
Table 3-19 Domestic WWTF – Maximum Allowable Headworks Loadings

Pollutant

Allowable
Headworks (Water
Quality) (lbs/day)

Allowable
Headworks (Sludge)
(lbs/day)

Allowable
Headworks
(Inhibition)
(lbs/day)

Maximum
Allowable
Headworks
(lbs/day)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.27
0.10
0.83
0.96
0.25
0.10
0.03
1.34
0.20
8.57
0.41
0.15
677.64

0.24
0.15
4.58
1.29
0.07
2.63
0.53
-

2.75
45.42
20.82
5.35
4.84
19.22
3.75
6.46
0.00
5.71
10,842.28

0.24
0.10
0.83
0.96
0.25
0.10
0.03
1.34
0.00
5.71
0.41
0.15
677.64

26

Page 151

Page 152 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

3.2.4. Designating Local Limits
Following the calculation of the MAHLs for each POC, the next step is to identify which POCs require the
development of local limits. In accordance with the EPA’s Local Limits Development Guidance, local limits
should be established for any POC where the average influent loading exceeds 60% of its respective MAHL.
Tables 3-20 and 3-21 present comparisons of the calculated MAHLs and the average influent loadings for
each POC at the Industrial and Domestic WWTFs, respectively. Pollutants exceeding the 60% threshold
are flagged for further evaluation and the development of site-specific local limits to ensure compliance
and protect treatment processes.
Table 3-20 Industrial WWTF - Comparison of MAHLs with Average Headworks Loadings

Pollutant

Maximum
Allowable
Headworks
(lbs/day)

Average Influent
Loading (lbs/day)

Average Percent
Loaded

New Local Limit
Required?

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.08
0.04
0.33
0.38
0.10
0.04
0.01
0.53
0.00
2.26
0.16
0.06
177.65

0.03
0.00
0.02
1.38
0.02
0.20
0.001
0.03
0.02
1.43
0.01
0.06
33.75

38%
8%
6%
363%
24%
515%
10%
6%
0%
63%
9%
100%
19%

No
No
No
Yes
Yes
Yes
No
No
No
Yes
No
Yes
No

Table 3-21 presents a comparison of the calculated MAHLs and average influent loadings for each POC at
the Domestic WWTF, identifying those that exceed 60% of the MAHL and require the development of
local limits.
Table 3-21 Domestic WWTF - Comparison of MAHLs with Average Headworks Loadings

Pollutant

Maximum
Allowable
Headworks
(lbs/day)

Average Influent
Loading (lbs/day)

Average Percent
Loaded

New Local Limit
Required?

Arsenic
Cadmium
Chromium
Copper

0.24
0.10
0.83
0.96

0.05
0.01
0.08
0.89

21%
7%
9%
92%

No
No
No
Yes

27

Page 152

Page 153 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-21 Domestic WWTF - Comparison of MAHLs with Average Headworks Loadings

Pollutant

Maximum
Allowable
Headworks
(lbs/day)

Average Influent
Loading (lbs/day)

Average Percent
Loaded

New Local Limit
Required?

Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.25
0.10
0.03
1.34
0.00
5.71
0.41
0.15
677.64

0.04
0.03
0.002
0.08
0.04
3.43
0.04
0.10
415.62

18%
35%
8%
6%
0%
60%
10%
69%
61%

No
No
No
No
No
Yes
No
Yes
Yes

3.2.5. Background Loadings for Non-Industrial Sources
An essential component of the local limits development process is the quantification of background
pollutant loadings from non-industrial sources. In accordance with the U.S. EPA’s Local Limits
Development Guidance, these background contributions, typically originating from residential,
commercial, and other uncontrolled sources, must be accurately characterized and deducted from the
treatment facility’s capacity to ensure that allowable loadings allocated to industrial users do not cause
pass-through, interference, or violations of applicable discharge requirements.
At the City of Sanger, Domestic WWTF receives influent wastewater from a combination of residential,
commercial, and four permitted industrial users: Initiative Foods, International Paper, and Pitman Family
Hatchery, and GBI USA Co. In contrast, the Industrial WWTF exclusively receives flow from two SIUs and
does not accept contributions from residential or commercial users. The Industrial WWTF does not receive
hauled waste, and due to the facility’s separately design, the potential for inflow and infiltration is
minimal. As a result, there are no uncontrolled sources contributing to the Industrial WWTF, and the full
MAHL for each pollutant is available for allocation to the permitted industrial users, subject to applicable
safety factors and growth allowances as specified in EPA guidance. Uncontrolled background loadings are
only applicable to the Domestic WWTF.
To estimate non-industrial contributions, the City conducted sampling at seven lift stations that primarily
collect flow from residential and commercial areas. While GBI USA Co. discharges to the City’s
Academy/Commerce lift station the other industrial users connect directly to the sewer lines feeding the
Domestic WWTF, minimizing overlap. Sampling data from the five lift stations that do not receive any
industrial discharges, provided in Appendix A, were used to characterize pollutant concentrations from
non-industrial sources. The mass loadings from these sources were calculated using Equation 4 from EPA
guidance.
Equation 4 – Residential and Background Loading Calculation
𝐿𝑈𝑁𝐶 = (𝐶𝑈𝑁𝐶 ) (𝑄𝑈𝑁𝐶 )(8.34)

28

Page 153

Page 154 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Where:
LUNC = Uncontrolled loading, lb/day
CUNC = Uncontrolled pollutant concentration, mg/L
QUNC = Uncontrolled flow rate, MGD
8.34 = Conversion factor
The uncontrolled flow rate (QUNC) was determined by subtracting the total industrial flow (0.089 MGD)
from the average daily influent flow to the Domestic WWTF (1.80 MGD) for 2024, resulting in a
background flow of 1.71 MGD. Pollutant concentrations (CUNC) were derived from the lift station sampling
data, and the calculated loadings (LUNC) are summarized in Table 3-22. This background loading analysis
ensures that local limits developed for the Domestic WWTF accurately reflect the capacity available for
industrial discharges, consistent with EPA methodology and the City’s treatment system design.
Table 3-22 Estimated Background Loadings from Non-Industrial Sources

Pollutant

Uncontrolled
Flow
(MGD)(QUNC)

Uncontrolled
Pollutant
Concentration
(mg/L) (CUNC)

Nonindustrial
Loading (lbs/day)
(LUNC)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

1.71
1.71
1.71
1.71
1.71
1.71
1.71
1.71
1.71
1.71
1.71
1.71
1.71

0.003
0.000
0.004
0.059
0.003
0.002
0.000
0.005
0.003
0.220
0.002
0.007
25.820

0.048
0.006
0.061
0.844
0.041
0.034
0.003
0.077
0.036
3.135
0.035
0.104
368

3.2.6. Maximum Allowable Industrial Loadings
The Maximum Allowable Industrial Loading (MAIL) represents the portion of a pollutant’s headworks
loading capacity that may be allocated to industrial sources without exceeding the treatment facility’s
operational or regulatory thresholds. For both the Domestic and Industrial WWTFs, MAIL values are
derived by subtracting background loadings from non-industrial sources and applying a safety factor to
account for variability and uncertainty. MAIL values are calculated using Equation 5 from the U.S. EPA’s
Local Limits Development Guidance.
Equation 5 – MAIL Calculation

29

Page 154

Page 155 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

𝑀𝐴𝐼𝐿 = 𝑀𝐴𝐻𝐿(1 − 𝑆𝐹) − (𝐿𝑈𝑁𝐶 + 𝐻𝑊 + 𝐺𝐴)
Where:
MAIL = Maximum allowable industrial loading, lb/day
MAHL = Maximum allowable headworks loading, lb/day
SF = Safety factor, decimal
LUNC = Loadings from uncontrolled sources, lb/day
HW = Loadings from hauled waste, if not regulated through the local limits, lb/day
GA = Growth allowance, lb/day
3.2.6.1. Safety Factor and Growth Allowances
To account for variability and uncertainty in the data used to develop MAHLs, a safety factor is applied
when calculating the MAILs. In accordance with EPA’s Local Limits Development Guidance, a minimum 10
percent safety factor has been applied uniformly across all pollutants of concern. This conservative
approach helps protect each facility from fluctuations in industrial discharge characteristics and ensures
continued compliance with effluent and sludge quality objectives.
A growth allowance is an optional portion of the MAHL that may be reserved to accommodate future
increases in pollutant loadings resulting from industrial expansion. However, the City of Sanger is not
currently aware of any major industrial growth or expansion that would affect the Industrial or Domestic
WWTF’s influent characteristics. As such, no growth allowance has been included in this evaluation.
3.2.6.2. Industrial WWTF MAIL Evaluation
The Industrial WWTF currently only receives wastewater from two SIUs: Pitman Farms and Gibson Winery.
Because the facility does not receive residential, commercial, or hauled waste contributions, background
loading is considered negligible (LUNC = 0). Therefore, the full MAHL, adjusted for the 10% safety factor, is
available for allocation to the permitted SIUs, as shown in Table 3-23 below.
Table 3-23 Industrial WWTF – Maximum Allowable Industrial Loadings

Pollutant

Maximum
Allowable
Headworks
Loading
(lbs/day)
(MAHL)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury

0.08
0.04
0.33
0.38
0.10
0.04
0.01

Safety
Factor
(SF)

Nonindustrial
Loading
(lbs/day)
(LUNC)

Hauled
Waste
Loading
(lbs/day)
(HW)

Growth
Allowance
(%)
(GA)

Maximum
Allowable
Industrial
Loading
(lbs/day)
(MAIL)

10%
10%
10%
10%
10%
10%
10%

0
0
0
0
0
0
0

0
0
0
0
0
0
0

0
0
0
0
0
0
0

0.07
0.04
0.30
0.34
0.09
0.03
0.01

30

Page 155

Page 156 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-23 Industrial WWTF – Maximum Allowable Industrial Loadings

Pollutant

Maximum
Allowable
Headworks
Loading
(lbs/day)
(MAHL)

Safety
Factor
(SF)

Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.53
0.00
2.26
0.16
0.06
177.65

10%
10%
10%
10%
10%
10%

Nonindustrial
Loading
(lbs/day)
(LUNC)

Hauled
Waste
Loading
(lbs/day)
(HW)

Growth
Allowance
(%)
(GA)

Maximum
Allowable
Industrial
Loading
(lbs/day)
(MAIL)

0
0
0
0
0
0

0
0
0
0
0
0

0
0
0
0
0
0

0.48
0.00
2.03
0.14
0.05
159.88

3.2.6.3. Domestic WWTF MAIL Evaluation
At the Domestic WWTF, influent flows are derived from a mix of residential, commercial, and small-scale
industrial sources. As a result, background loadings from uncontrolled (non-industrial) contributors (LUNC)
must be deducted from the facility’s overall loading capacity before determining the allowable loadings
for the industrial users. Applying the same assumptions used for the Industrial WWTF, a 10 percent safety
factor and zero growth allowance, the MAILs for the Domestic WWTF were calculated using Equation 6.
These values reflect the portion of the capacity available for industrial dischargers after accounting for
non-industrial contributions. Table 3-24 presents the resulting MAILs for each pollutant of concern.
Table 3-24 Domestic WWTF – Maximum Allowable Industrial Loadings

Pollutant

Maximum
Allowable
Headworks
Loading
(lbs/day)
(MAHL)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium

0.24
0.10
0.83
0.96
0.25
0.10
0.03
1.34
0.00
5.71
0.41
0.15

Safety
Factor
(SF)

Nonindustrial
Loading
(lbs/day)
(LUNC)

Hauled
Waste
Loading
(lbs/day)
(HW)

Growth
Allowance
(%)
(GA)

Maximum
Allowable
Industrial
Loading
(lbs/day)
(MAIL)

10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%

0.051
0.006
0.069
0.789
0.043
0.034
0.002
0.078
0.036
3.337
0.038
0.111

0
0
0
0
0
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0
0
0
0

0.16
0.08
0.68
0.08
0.18
0.05
0.02
1.13
0.00
1.80
0.33
0.02

31

Page 156

Page 157 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-24 Domestic WWTF – Maximum Allowable Industrial Loadings

Pollutant

Maximum
Allowable
Headworks
Loading
(lbs/day)
(MAHL)

Safety
Factor
(SF)

Ammonia

677.64

10%

Nonindustrial
Loading
(lbs/day)
(LUNC)

Hauled
Waste
Loading
(lbs/day)
(HW)

Growth
Allowance
(%)
(GA)

Maximum
Allowable
Industrial
Loading
(lbs/day)
(MAIL)

392.084

0

0

217.79

3.2.7. Local Limits Allocation
After calculating the MAIL for each POC, the next step in the local limits development process is to allocate
these loadings among permitted industrial dischargers. The allocation approach must ensure equitable
distribution of pollutant loadings while maintaining compliance with regulatory requirements and
protecting the integrity of the wastewater treatment systems. Two primary methods are recognized by
the EPA for allocating MAILs:
1. Uniform Allocation Method – Assigns a single, concentration-based local limit to all permitted
SIUs, regardless of their individual flow or pollutant contribution.
2. Industrial User-Specific Allocation Method – Distributes the MAILs proportionally based on each
SIU’s flow volume or pollutant load contribution.
The selection of the allocation method depends on the number and characteristics of industrial users,
variability of discharges, administrative feasibility, and system configuration.
3.2.8. Industrial WWTF – Evaluation of Local Limits
The two SIUs that discharge wastewater to the City’s Industrial WWTF exhibit similar influent
characteristics and pollutant profiles. Given this limited and uniform user base, the Uniform Allocation
Method is appropriate and consistent with U.S. EPA guidance.
The Uniform Allocation Method assigns a single concentration-based local limit to all permitted industrial
users. This approach is consistent with U.S. EPA guidance and is appropriate when users have similar
pollutant profiles. Under the uniform method, the MAIL for each pollutant is converted into a single
concentration-based local limit applicable to all SIUs. This limit is calculated using Equation 6.
Equation 6 – Uniform Allocation Calculation
𝐶𝐿𝐼𝑀 =

𝑀𝐴𝐼𝐿
(𝑄𝑆𝐼𝑈 × 8.34)

Where:
CLIM = Uniform concentration limit, mg/L
MAIL = Maximum allowable industrial loading, lb/day
MAHL = Maximum allowable headworks loading, lb/day
QSIU = Total flow rate from SIUs, MGD
8.34 = Conversion factor

32

Page 157

Page 158 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

This method ensures equitable application of local limits across both SIUs and simplifies permit
administration, monitoring, and compliance tracking. Table 3-25 provides the proposed local limits based
on the uniform allocation method.
Table 3-25 Industrial WWTF – Uniform Allocation of Local Limits

Pollutant

MAIL
(lbs/day)
(MAIL)

Total Industrial
Flow (MGD)
(QSIU)

Proposed
Local Limit
(mg/L)
(CLIM)

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.07
0.04
0.30
0.34
0.09
0.03
0.01
0.48
0.00
2.03
0.14
0.05
159.88

0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.71

0.012
0.006
0.050
0.058
0.015
0.006
0.002
0.081
0.000
0.343
0.024
0.009
27.00

3.2.9. Domestic WWTF – Evaluation of Local Limits
For the Domestic WWTF, the uniform allocation method described in Equation 6 was used to derive
pollutant-specific local limits presented in Table 3-26. This approach distributes the MAIL evenly across
the industrial flow to Domestic WWTF, which is approximately 0.089 MGD. The resulting concentrationbased limits (CLIM) represent the maximum allowable discharge strength for each pollutant of concern to
ensure compliance with the applicable MAHLs and continued protection of treatment performance and
disposal operations.
Table 3-26 Domestic WWTF – Uniform Allocation of Local Limits

Pollutant

MAIL
(lbs/day)
(MAIL)

Total Industrial
Flow (MGD)
(QSIU)

Proposed
Local Limit
(mg/L)
(CLIM)

Arsenic
Cadmium

0.16
0.08

0.089
0.089

0.22
0.11

33

Page 158

Page 159 of 179

City of Sanger
Local Limits Study
Section 3 – Development of Local Discharge Limits

Table 3-26 Domestic WWTF – Uniform Allocation of Local Limits

Pollutant

MAIL
(lbs/day)
(MAIL)

Total Industrial
Flow (MGD)
(QSIU)

Proposed
Local Limit
(mg/L)
(CLIM)

Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
Ammonia

0.68
0.08
0.18
0.05
0.02
1.13
0.00
1.80
0.33
0.02
217.79

0.089
0.089
0.089
0.089
0.089
0.089
0.089
0.089
0.089
0.089
0.089

0.92
0.11
0.25
0.07
0.03
1.53
0.00
2.44
0.44
0.03
294.35

34

Page 159

Page 160 of 179

City of Sanger
Local Limits Study
Section 4 – Proposed Local Limits

SECTION 4 - PROPOSED LOCAL LIMITS
After evaluating pollutant loadings at both the Domestic and Industrial WWTFs using facility design
criteria, applicable WDRs, and the U.S. Environmental Protection Agency’s Local Limits Development
Guidance, this section consolidates those findings into a set of proposed local discharge limits for the City
of Sanger. The proposed limits intend to protect facility performance, ensure regulatory compliance, and
provide an equitable allocation of capacity between residential and industrial users. Through the
implementation of these limits, the City will maintain discharges within each facility’s treatment
capabilities, safeguard effluent and biosolids quality, and preserve sufficient capacity to accommodate
future growth. The following subsections present a comparison of existing and proposed limits and outline
the recommended actions for implementation.

4.1.

Comparison of Existing and Proposed Limits

Table 4-1 presents a comparison of the City’s existing and proposed local limits for both the Industrial and
Domestic WWTFs. It identifies the POCs that warrant enforceable limits and specifies how those limits
must be adjusted to ensure continued regulatory compliance and protection of treatment processes.
In addition to the local limits evaluated in Section 3, the City should establish local limits for both pH and
Fats, Oils, and Grease (FOG) to ensure continued protection of the treatment facilities and collection
system. A pH range of 6.0 to 9.0 standard units is recommended for both facilities to ensure optimal
biological treatment performance and prevent structural deterioration. In no case shall wastewater with
a pH lower than 5.0 be accepted, as such wastes are corrosive and can cause severe damage to concrete,
metal, and mechanical components throughout both treatment facilities. Establishing this range will
provide adequate protection against both corrosion and chemical scaling, ensuring long-term structural
and operational reliability.
Similarly, a local limit for FOG is recommended to minimize the potential for blockages, pond surface scum
accumulation, and operational interference within the aerated and storage ponds. Excessive FOG can
reduce oxygen transfer efficiency and contribute to premature solids buildup. Based on EPA’s Local Limits
Development Guidance and standard industry practices for lagoon-based treatment systems, a
concentration-based limit of 100 mg/L is recommended. This value is consistent with 40 CFR 403.5(b)(3),
which prohibits discharges capable of causing obstruction to flow in the POTW, and provides a technically
defensible threshold for maintaining reliable treatment performance and infrastructure protection.
Table 4-1 Comparison of Existing and Proposed Local Limits
Industrial WWTF
Pollutant

Existing Local
Limit(1)

Arsenic
Cadmium
Chromium
Copper
Cyanide

1.0 mg/L
0.7 mg/L
1.0 mg/L
1.0 mg/L
1.0 mg/L

Domestic WWTF

Proposed
Local Limit

Required
Local Limit

Proposed
Local Limit

Required
Local Limit

0.012 mg/L
0.006 mg/L
0.05 mg/L
0.058 mg/L
0.015 mg/L

No
No
No
Yes
Yes

0.22 mg/L
0.11 mg/L
0.93 mg/L
0.03 mg/L
0.25 mg/L

No
No
No
Yes
No

35

Page 160

Page 161 of 179

City of Sanger
Local Limits Study
Section 4 – Proposed Local Limits

Table 4-1 Comparison of Existing and Proposed Local Limits
Industrial WWTF
Pollutant

Existing Local
Limit(1)

Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium

Domestic WWTF

Proposed
Local Limit

Required
Local Limit

Proposed
Local Limit

Required
Local Limit

0.4 mg/L
0.01 mg/L
1.0 mg/L
0.7 mg/L
1.0 mg/L
None
2.0 mg/L

0.006 mg/L
0.002 mg/L
0.081 mg/L
0.00 mg/L
0.343 mg/L
0.024 mg/L
0.009 mg/L

Yes
No
No
No
Yes
No
Yes

0.07 mg/L
0.03 mg/L
1.53 mg/L
0.00 mg/L
2.71 mg/L
0.45 mg/L
0.04 mg/L

No
No
No
No
Yes
No
Yes

BOD5

300 mg/L

Total Suspended Solids
Ammonia
EC
pH
FOG

300 mg/L
0.32 mg/L
700 µmhos/cm
6.5 – 8.5
100 mg/L

1,000 mg/L
600mg/L
27 mg/L
700 µmhos/cm
6.0 – 9.0
100 mg/L

Yes
Yes
No
Yes
Yes
Yes

500 mg/L
500 mg/L
327 mg/L
1,000 µmhos/cm
6.0 – 9.0
100 mg/L

Yes
Yes
Yes
Yes
Yes
Yes

Note:
(1)
Existing Local Limit are detailed in Section 82-175 of the City of Sanger's Municipal Code and pertain to
both the Industrial and Domestic WWTFs.

4.2.

Recommended Action and Conclusion

Based on the evaluation of pollutant loadings at both the Domestic and Industrial WWTFs, the proposed
local limits summarized in this Study represent the most appropriate limits for implementation by the City
of Sanger. Adoption of these limits will ensure that discharges from industrial users do not interfere with
treatment processes, compromise effluent or biosolids quality, exceed design capacity, or cause violations
of the City’s WDRs. The recommended limits also provide a fair and equitable allocation of treatment
capacity between residential and industrial users, while preserving sufficient capacity to accommodate
reasonable future growth.
It is recommended that the City proceed with the adoption and implementation of the proposed required
local limits presented in Table 4-1 for both the Domestic and Industrial WWTFs and incorporate them into
the City’s Industrial Pretreatment Program and Municipal Code. These enforceable limits will provide the
regulatory basis for managing industrial discharges, issuing permits, and taking corrective actions where
necessary to protect the City’s treatment infrastructure and water resources. Implementation of these
local limits will enable the City of Sanger to maintain compliance with federal and state pretreatment
regulations, uphold water quality protections, and continue providing reliable wastewater treatment
service to the community.

36

Page 161

Page 162 of 179

City of Sanger
Local Limits Study
Appendix A - Residential Background Sampling

APPENDIX A
RESIDENTIAL BACKGROUND SAMPLING

37

Page 162

Page 163 of 179

Pollutant

Units

Reporting Limit

Arsenic
Cadmium
Chromium
Copper
Cyanide
Lead
Mercury
Nickel
Silver
Zinc
Molybdenum
Selenium
BOD5
Total Suspended Solids
Ammonia
EC
Notes:

mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L

0.01
0.001
0.005
0.005
0.005
0.005
0.0002
0.005
0.005
0.005
0.005
0.020

Analytical
Method
EPA 200.7
EPA 200.7
EPA 200.7
EPA 200.7
SM 4500-CN E
EPA 200.7
EPA 245.1
EPA 200.7
EPA 200.7
EPA 200.7
EPA 200.7
EPA 200.7

mg/L
mg/L
mg/L
µs/cm

100
20
5.0
1

SM 5210 B
SM 2540 D
EPA 350.1
SM 2510 B

Church & J
Day 1 Result
Day 2 Result
0.0039
0.005
0.0005
0.00023
0.0036
0.007
0.029
0.039
0.0025
0.0025
0.0025
0.0025
0.0001
0.0001
0.0033
0.0085
0.0025
0.0025
0.12
0.15
0.0021
0.0026
0.01
0.01
350
700
120
190
26
6.3
120
190

Appendix A
Residential Background Sampling
North & Greenwood
Newmark & Annadale
Day 1 Result
Day 2 Result
Day 1 Result
Day 2 Result
0.0037
0.0036
0.0064
0.0026
0.0005
0.00059
0.00048
0.0005(1)
0.0036
0.0035
0.012
0.0029
0.027
0.044
0.064
0.0081
0.0025
0.0025
0.005
0.0025
0.0025
0.0025
0.002
0.0025
0.0001
0.0001
0.0001
0.0001
0.0027
0.0077
0.0084
0.0033
0.0025
0.0025
0.0025
0.0025
0.13
0.51
0.49
0.12
0.0025
0.0022
0.0054
0.0022
0.01
0.0012
0.01
0.01
190
290
740
400
310
210
490
40
63
8.8
59
13
870
720
900
880

Muscat & Commerce
Day 1 Result
Day 2 Result
0.0011
0.0019
0.0005
0.00025
0.0034
0.0064
0.27
0.1
0.0025
0.0025
0.0024
0.0015
0.0001
0.0001
0.0059
0.0072
0.0025
0.0025
0.099
0.33
0.0013
0.0022
0.01
0.001
250
320
130
76
73
14
1200
1400

5th & Reagen
Day 1 Result
Day 2 Result
0.0037
0.0038
0.0005
0.0005
0.0055
0.0028
0.024
0.023
0.0025
0.0025
0.0025
0.0025
0.0001
0.0001
0.0025
0.0013
0.0025
0.0025
0.095
0.046
0.0025
0.0024
0.01
0.01
230
210
99
83
18
6.1
510
690

8th & Tucker
Day 1 Result
Day 2 Result
0.0037
0.0032
0.00033
0.0005
0.0047
0.0026
0.026
0.01
0.0066
0.0025
0.0025
0.0025
0.00086
0.0001
0.013
0.0018
0.0025
0.0025
0.61
0.11
0.0034
0.0035
0.01
0.001
410
270
330
88
29
14
820
860

Average
Concentration
0.004
0.000
0.005
0.055
0.003
0.002
0.000
0.005
0.003
0.234
0.003
0.008
363
181
28
763

(1)

For reporting purposes, concentrations listed as "Not Detected" are interpreted as one-half of the laboratory detection limit.

Page 163

Page 164 of 179

For the Meeting of: February 19, 2026
Agenda Item No.: G-1

CITY OF SANGER

REPORT TO THE CITY COUNCIL
To:

Mayor and Councilmembers

From:

Dr. Joshua Goggins, Community Development Director

Subject:

Initiation of Annexation of Real Property for Regional Storm Drain Facility –
Property located on the South Side of North Avenue Between Indianola and
Bethel Avenues (APN 332-080-40).

Attachments:
1. City Council Resolution No. 2026-12
2. Ordinance No. 2026-02
CONFLICT OF INTEREST:
None known.
RECOMMENDATION:
1. Staff Recommends that City Council adopt Resolution 2026-12 to request the Fresno Local
Agency Formation Commission (Fresno LAFCO) to take proceedings for the Annexation of a
planned Regional Storm Water Drain Facility and Associated Finding of Exemption Under
Public Resources Code Section 21083.3 and California Environmental Quality Act (CEQA)
Guidelines Section 15183.
2. Waive the full reading and introduce, by title only, Ordinance No. 2026-02 an ordinance of the
City Council of the City of Sanger approving Zoning Ordinance Map Amendment No 2026-01
for pre-annexation zoning from Fresno County’s AE-20 (Exclusive Agriculture) to the City’s
RSC (Recreation, Schools, and Conservation) zone district for approximately 11.42 acres located
on the south side of North Avenue between Indianola and Bethel Avenues (APN 332-080-40)
PROJECT BACKGROUND:
The project site consists of approximately 11.42 acres of land and associated public right-of-way
generally bounded by East North Avenue to the north, South Indianola Avenue to the west, and
South Bethel Avenue to the east. The subject property is located within Fresno County and within
Prepared by:

Derek Sylvester

REVIEW:

City Manager:

TYPE OF ITEM:

X

Consent
Informational Item
Action Item
Department Report

Approved by:
Finance:

City Attorney:

COUNCIL ACTION:  APPROVED  DENIED  NO ACTION

X

Public Hearing
Matter Initiated by a Council Member
Other:
Continued to:

Page 164

Page 165 of 179

the City of Sanger’s Sphere of Influence.
At its meeting of October 16, 2025, the City Council issued final approvals, including initiation of
annexation, for the subdivision known as Tentative Tract 6493, being developed by Lennar Homes
of California (Lennar). One of the conditions of approval of that project is to acquire and construct
(at least initially) the master-planned storm drainage basin facility for the Southwest Drainage Area,
as defined by the City’s Storm Drain Master Plan (“Basin Condition”). The location of this regional
basin facility has been planned for almost a quarter of a century and was defined as early as 2003
with the 2025 General Plan and was also included with the City’s current 2035 General Plan. This
regional stormwater drain facility is anticipated to serve a 450-acre area, including Phase 1 of the
Lennar development, which is approximately 40 acres. See Attachment 1 for the adopted Land Use
Map where the basin area is highlighted and see Attachment 2 for aerial and street views of the
project area.
The property of the location of the proposed regional stormwater drain facility is owned by
Choolijian Farms (“Choolijian”). The City Council previously authorized an agreement to transfer
title of the property to the City.
As previously flagged for the Council, the property for the regional stormwater drain facility is
currently outside of City limits, but within the City’s sphere of influence. As a result, this property
will need to be pre-zoned and annexed into the City. Additionally, the California Government Code
requires a finding of General Plan conformity and review for the same by the Planning Commission,
and a CEQA assessment for the project as may be appropriate.
This staff report addresses the required pre-zoning and initiation of annexation proceedings with the
Fresno Local Agency Formation Commission (Fresno LAFCO) to allow implementation of storm
drainage facilities and to ensure consistency with the City’s 2035 General Plan and zoning
regulations upon annexation.
INITIATION OF ANNEXATION:
The basin property is located outside of City limits, consisting of approximately 11.42 acres generally
located on the south side of North Avenue between Indianola and Bethel Avenues (APN 332-080-40). Per
the Memorandum of Understanding between the City and County, specific procedures must be taken to in
order to change jurisdiction of property from County to City. The Fresno Local Agency Formation
Commission (Fresno LAFCO) is the authority in decisions on change of organization boundaries (City
Limits), including annexations. Planning Commission recommended initiation to City Council at a public
hearing held on January 29, 2026. The first step in this process is initiation of annexation by the City via
resolution directing staff to proceed with application to Fresno LAFCO.
GENERAL PLAN CONFORMITY:
California Government Code Section 65402 requires that the City cannot acquire real property for public
purposes until the matter has been submitted to the Planning Commission for a report as to conformity with
the adopted General Plan. This matter was considered by the Planning Commission at its meeting on
November 10, 2025, and the Planning Commission found that the proposed regional stormwater drain
facility on the Choolijian property was consistent with the City’s adopted 2035 General Plan.
As stated earlier, Attachment 1 shows the Land Use Map from the adopted 2035 General Plan and
depicts a “Storm Drain Facility” within the Choolijian property. Attachment 3 shows the planned
location of the actual basin, which aligns more or less with the existing topography of the site,
which can be seen in the street and aerial views in Attachment 2. The low-lying topography, as
Page 165
01484.0005 2092427.1

Page 166 of 179

well as the location relative to the 450-acres being served by the proposed basin, were part of the
initial site determination for the facility. As a result, the proposed location is in substantial
conformance to the 2035 General Plan.
ZONING ORDINANCE CONFORMITY:
The subject property is outside of the city limits. Therefore, prezoning is required to match the
General Plan Land Use. The subject property will go from County of Fresno: AE-20 (Exclusive
Agricultural) to City of Sanger RSC (Recreation, Schools and Conservation) zone district. The
RSC zone district is consistent with the 2035 General Plan designation of Storm Drain Facility.
ENVIRONMENTAL ANALYSIS
Staff have evaluated the proposed project in accordance with CEQA Guidelines section 15183, which
allows streamlined environmental review for projects that are consistent with the development density and
policies of an adopted General Plan for which an EIR has been certified.
Based on staff review of the 2035 General Plan and the certified General Plan EIR, the proposed storm
drain basin project is proposed to be found to be consistent with the General Plan and within the scope of
the impacts analyzed in the General Plan EIR, for the following reasons:
1. The project is consistent with the development density established by existing zoning, community
plan or general plan policies for which an EIR was certified.
• The project site is designated “Storm Drain Facility” under the 2035 General Plan. Storm
drainage basins and related public utility infrastructure are allowed uses within this
designation.
2. There are no project specific effects which are peculiar to the project or its site.
• The proposed storm drain basin directly implements these policies and does not conflict with
any General Plan objectives.
• There are no unique features or other unusual conditions of the property that would give rise
to specific effect peculiar to the site; this is a property of a type generally found throughout
the 2035 General Plan planning area and common to the area.
3. There are no project specific impacts which the EIR for the General Plan failed to analyze as
significant effects.
• The project is within the development intensity and infrastructure assumptions considered
in the EIR.
4. There are no potentially significant off-site and/or cumulative impacts which the GPU EIR failed to
evaluate. There is no substantial new information which results in more severe impacts than
anticipated by the EIR for the General Plan Update.
• There are no substantial changes to the project, circumstances, or regulatory environment
that would trigger the need for a subsequent or supplemental EIR. The project qualifies for
reliance on the General Plan EIR under CEQA Guidelines §15183, and preparation of
additional CEQA documents is not required.
As a result, no further analysis is required by CEQA, and the City Council may adopt an exemption for this
project pursuant to Public Resources Code Section 21083.3 and CEQA Guidelines Section 15183.

REASON FOR RECOMMENDATION:
The property has been planned for a regional storm drain facility for decades and is designated as such in
01484.0005 2092427.1

Page 166

Page 167 of 179

the 2035 General Plan. The acquisition and construction of the basin is a condition of approval of Tract
6493, which has been approved by the Planning Commission and the City Council. The basin will provide
a regional benefit and the acquisition of real property for this use will be in substantial conformance to the
2035 General Plan.
FISCAL IMPACT:
No fiscal impact.
ALTERNATIVES:
The City Council may choose not to adopt the resolution. If so, staff requests the Council provide direction
on next steps.
ACTIONS FOLLOWING APPROVAL:
The acquisition of the property is contingent upon close of escrow and transfer of the property to the City.
As part of the process, staff will submit the annexation resolution to Fresno LAFCO.

01484.0005 2092427.1

Page 167

Page 168 of 179

RESOLUTION NO. 2026-12
A RESOLUTION OF APPLICATION OF THE CITY COUNCIL OF THE CITY
OF SANGER REQUESTING THE LOCAL AGENCY FORMATION
COMMISSION TO TAKE PROCEEDINGS FOR THE REORGANIZATION OF
ANNEXATION NO. 2026-01 AND ASSOCIATED PARCELS (INITIATE
ANNEXATION)
WHEREAS, Ara Chekerdemian (Lennar Homes of California, LLC), on behalf of
property owner G4 Properties, LTD (“Applicant”), submitted applications to the City for initiation
of annexation (Annexation No. 2026-01, ANX 2026-01), pre-zoning (Zoning Ordinance
Amendment No. 2026-01, ZOA 2026-01), to develop a regional storm drain facility,
approximately 11.42 acres generally located south of North Avenue, east of Indianola Avenue,
and west of Bethel Avenue (APN 332-080-40) (the “Affected Territory”); and
WHEREAS, Government Code section 56654 provides that “[a] proposal for a change of
organization or a reorganization may be made by the adoption of a resolution of application by the
legislative body of an affected local agency;” and
WHEREAS, the specific changes of organization requested consists of annexation to the
City of Sanger and detachment from the County of Fresno and associated fire protection, irrigation,
and other districts; and
WHEREAS, the Affected Territory proposed to be changed is uninhabited, and on this
day contains zero registered voters, according to information received from the County Elections
Office because there are no dwellings or structures on the site; and
WHEREAS, a written description and map of the boundaries of the Affected Territory is
set forth in Exhibit “A” attached hereto and by this reference incorporated herein; and
and

WHEREAS, this proposal is consistent with the Sphere of Influence of the City of Sanger;

WHEREAS, the City has an agreement with the County of Fresno to comply with Revenue
and Tax Code section 99 regarding property tax revenue transfer upon annexation, which
agreement includes standards of annexations; and
WHEREAS, the City does not propose any specific term and conditions for the proposed
reorganization; and
WHEREAS, the proposed annexation and pre-zoning have been reviewed for compliance
with the California Environmental Quality Act (CEQA), and the action is within the scope of the
environmental analysis previously completed for the project; and
WHEREAS, the Planning Commission of the City of Sanger did conduct a duly noticed
public hearing in the Council Chambers of the Sanger City Hall in Sanger, California, on January

Page 168

Page 169 of 179

29, 2026, to consider a recommendation of approval to the City Council for ANX 2026-01 and
ZOA 2026-01, at which time all interested parties were given an opportunity to be heard and
present evidence; and
WHEREAS, the Planning Commission has held public hearings and recommended the
City Council to initiate proceedings for the reorganization of the Affected Territory as further
described in Exhibit “A” in the manner provided by the Cortese-Knox-Hertzberg Local
Government Reorganization Act of 2000; and
WHEREAS, the City Council now desires to approve Annexation 2026-01.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Sanger as
follows:
Section 1.

Recitals. The City Council hereby finds that all of the facts set forth in the recitals
above are true and correct and incorporated herein.

Section 2.

CEQA. The City Council finds the project is consistent with the 2035 General Plan,
and that all potentially significant impacts were addressed in the 2035 General Plan
EIR (SCH#2003011060). Specifically, the City Council finds the project consistent
with the General Plan and within the scope of the impacts analyzed in the General
Plan EIR, for reasons including the following:
1.
The project is consistent with the development density established by
existing zoning, community plan or general plan policies for which an EIR was
certified. The project site is designated “Storm Drain Facility” under the 2035
General Plan. Storm drainage basins and related public utility infrastructure are
allowed uses within this designation.
2.
There are no project specific effects which are peculiar to the project or its
site. The proposed storm drain basin directly implements these policies and does
not conflict with any General Plan objectives. There are no unique features or other
unusual conditions of the property that would give rise to specific effect peculiar to
the site; this is a property of a type generally found throughout the 2035 General
Plan planning area and common to the area.
3.
There are no project specific impacts which the EIR for the General Plan
failed to analyze as significant effects. The project is within the development
intensity and infrastructure assumptions considered in the EIR.
4.
There are no potentially significant off-site and/or cumulative impacts
which the GPU EIR failed to evaluate. There is no substantial new information
which results in more severe impacts than anticipated by the EIR for the General
Plan Update. There are no substantial changes to the project, circumstances, or
regulatory environment that would trigger the need for a subsequent or
supplemental EIR. The project qualifies for reliance on the General Plan EIR under
CEQA Guidelines §15183, and preparation of additional CEQA documents is not
required.
As a result, no further analysis is required by CEQA, and the City Council adopts
an exemption for this project pursuant to Public Resources Code Section 21083.3

Page 169

Page 170 of 179

and CEQA Guidelines Section 15183.
Section 3.

General Plan Consistency for ZOA 2026-01. The City Council finds that ZOA
2026-01 is consistent with the goals, objectives, and policies of the 2035 General
Plan. In this regard, the City Council find that public necessity, convenience,
general welfare, and good zoning practices justify approval of ZOA 2026-01.
Specifically, the pre-zoning change is consistent with the 2035 General Plan goals
and policies, any operative plan, or adopted policy, and implements the planned
land uses in the Project area. The change is also consistent with the purpose of the
Development Code to promote the growth of the city in an orderly and sustainable
manner, and to promote and protect the public health, safety, peace, comfort, and
general welfare. The change is also necessary for good zoning practices to achieve
the balance of land uses desired by the City and to provide sites for needed
residential, parks, opens space, trails, and a recharge basin consistent with the 2035
General Plan

Section 4.

Initiation of Reorganization. The City Council adopts and approves this Resolution
of application, and initiates reorganization for the entire Affected Territory. The
Fresno Local Agency Formation Commission (Fresno LAFCO) is requested to
initiate proceedings for the change of organization of the territory described in
Exhibit “A” from the County of Fresno to the City of Sanger in the manner provided
by the Cortese-Knox-Hertzberg Local Government Reorganization Act of 2000,
including any associated districts such as the Fresno County Fire Protection
District, Fresno County Fire Protection District - Community Facilities District
Zone 2, Kings River Conservation District, and Consolidated Irrigation District.
The City Council directs the City Manager to take all necessary steps to submit a
complete application for the proposed reorganization, including preparation and
submittal of all Fresno LAFCO required forms, documents and studies and payment
of all required fees, at Applicant’s expense, in accordance with any applicable
agreement with the County of Fresno governing the same. The city anticipates that
this annexation maybe combined with the annexation of Tract 6493, when
submitted to Fresno LAFCO.

Section 5.

This Resolution shall become effective upon adoption of Zoning Ordinance
Amendment No. 2026-01.
* * * * * * * * * * * * * * * *

Page 170

Page 171 of 179

The foregoing was considered by the City Council of the City of Sanger at a regular meeting of
said Council held on the 19th day of February 2026, by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:

COUNCIL MEMBERS:
COUNCIL MEMBERS:
COUNCIL MEMBERS:
COUNCIL MEMBERS:

ATTEST:

APPROVED:

___________________________
Lina Martinez, City Clerk
City of Sanger

___________________________
Frank Gonzales, Mayor
City of Sanger

Page 171

Page 172 of 179

EXHIBIT A
AFFECTED TERRITORY

Page 172

Page 173 of 179

57

119

120

121

122

123

124

125

126

127

128

129

130

194

195

196

197

198

199

193

192

191

190

189

188

58
187

186

185

184

183

182

181

59

154
118

117

116

115

114

113

112

111

110

109

108

107

60

153

61
152
62
151
63
95

96

97

98

99

100

101

102

103

104

105

106

168

169

170

171

172

173

174

175

176

177

178

179

180
150

64
149
65

94

93

92

91

90

89

88

87

86

85

84

83

167

166

165

164

163

162

161

160

159

158

157

156

155
148

66
147
67
146
68
69

70

71

72

73

74

75

76

77

78

79

80

81

82

131

132

134

133

135

136

137

138

139

140

141

142

143

144

145

NORTH AVENUE

0
N
AP -080332

41
N
AP -080332

4
41
N
AP -080332

11.44 AC
498543 SF

40
80-

0
32-

N3
AP

-40
080

32-

N3

AP
05
N
AP -080332
34
N
AP -080332
N
AP -080
332

32-

N3

-29
080

AP

-35

21
N
AP -080332

09
N
AP -080332

22
N
AP -080332

12
N
AP -080332

N

CIVIL ENGINEERS I LAND SURVEYORS
P. 559-320-0344 I F. 559-320-0345 I WWW.GATEWAYENG.COM
405 PARK CREEK DRIVE, CLOVIS, CA 93611-4435

1
Page 173

1

Page 174 of 179

ORDINANCE NO. 2026-02
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANGER
APPROVING ZONING ORDINANCE MAP AMENDMENT NO 2026-01
FOR PRE-ANNEXATION ZONING FROM FRESNO COUNTY’S AE-20
(EXCLUSIVE AGRICULTURE) TO THE CITY’S RSC (RECREATION,
SCHOOLS, AND CONSERVATION) ZONE DISTRICT FOR
APPROXIMATELY 11.42 ACRES LOCATED ON THE SOUTH SIDE OF
NORTH AVENUE BETWEEN INDIANOLA AND BETHEL AVENUES
(APN 332-080-40)
WHEREAS, Ara Chekerdemian (Lennar Homes of California, LLC), on behalf of
property owner G4 Properties, LTD (“Applicant”), submitted applications to the City for initiation
of annexation (Annexation No. 2026-01, ANX 2026-01), pre-zoning (Zoning Ordinance
Amendment No. 2026-01, ZOA 2026-01), to develop a regional storm drain facility,
approximately 11.42 acres generally located south of North Avenue, east of Indianola Avenue,
and west of Bethel Avenue (APN 332-080-40 ); and
WHEREAS, the Project proposes a Regional Storm Drain Facility on 11.42 acres in the
Sphere of Influence of the City of Sanger; and
WHEREAS, the Project includes application ZOA 2026-01, to pre-zone the Project area
in anticipation of annexation, from the existing Fresno County AE-20 (Exclusive Agricultural, 20
acre minimum) zone district to the City of Sanger RSC (Resource, Schools and Conservation) zone
district for 11.42 acres of the Project area, consistent with the Land Use Designation Storm Drain
Facility; and
WHEREAS, the Project is currently within the City’s Sphere of Influence (“SOI”) but
outside the City limits, and is required to be annexed into the City before it can be developed to
urban uses, and the applicant has submitted application for annexation by ANX 2026-01 to initiate
annexation proceedings with the Fresno Local Agency Formation Commission (Fresno LAFCo);
and
WHEREAS, California Government Code subdivision 65859(a) states, a city may prezone unincorporated territory to determine the zoning that will apply to that territory upon
annexation to that city. The zoning shall become effective at the same time that the annexation
becomes effective; and
WHEREAS, the proposed annexation and pre-zoning have been reviewed for compliance
with the California Environmental Quality Act (CEQA), and the action is within the scope of the
environmental analysis previously completed for the project; and
WHEREAS, the Planning Commission of the City of Sanger did conduct a duly noticed
public hearing in the Council Chambers of the Sanger City Hall in Sanger, California, on January
29, 2026, to consider a recommendation of approval to the City Council for ANX 2026-01 and
ZOA 2026-01, at which time all interested parties were given an opportunity to be heard and

01484.0005 2092426.1

Page 174

Page 175 of 179

present evidence; and
WHEREAS, the City Council now desires to approve Zoning Ordinance Amendment
2026-01,
NOW, THEREFORE, the City Council of the City of Sanger does ordain as follows:
Section 1.

Recitals. The City Council hereby finds that all of the facts set forth in the recitals
above are true and correct and incorporated herein.

Section 2.

CEQA. The City Council finds the project is consistent with the 2035 General Plan,
and that all potentially significant impacts were addressed in the 2035 General Plan
EIR (SCH#2003011060). Therefore, the project is exempt from further
environmental review under CEQA Guidelines Section 15183.

Section 3.

General Plan Consistency for ZOA 2026-01. The City Council finds that ZOA
2026-01 is consistent with the goals, objectives, and policies of the 2035 General
Plan. In this regard, the City Council find that public necessity, convenience,
general welfare, and good zoning practices justify approval of ZOA 2026-01.
Specifically, the pre-zoning change is consistent with the 2035 General Plan goals
and policies, any operative plan, or adopted policy, and implements the planned
land uses in the Project area. The change is also consistent with the purpose of the
City’s zoning ordinance to promote the growth of the city in an orderly and
sustainable manner, and to promote and protect the public health, safety, peace,
comfort, and general welfare. The change is also necessary for good zoning
practices to achieve the balance of land uses desired by the City and to provide sites
for needed residential, parks, opens space, trails, and a recharge basin consistent
with the 2035 General Plan.

Section 4.

Approval of ZOA 2026-01 for a Regional Storm Drain Facility. The City Council
adopts this ordinance approving Zoning Amendment ZOA 2026-01 as set forth in
Exhibit “A” to this Ordinance.

Section 5.

Severability. If any provision of this Ordinance or the application thereof to any
person or circumstance is held invalid, such invalidity shall not affect other
provisions, or applications of this Ordinance that can be given effect without the
invalid provision or application, and to this end, the provisions of this Ordinance
are severable. The City Council hereby declares that it would have adopted this
Ordinance irrespective of the invalidity of any particular portion thereof.

Section 6.

Publication. The City Clerk is authorized to cause this ordinance or a summary of
this ordinance to be published in a newspaper of general circulation in the City of
Sanger, within fifteen days after its adoption. If a summary of the ordinance is
published, the City Clerk shall cause a certified copy of the full text of the proposed
ordinance to be posted at City Hall at least five days prior to the meeting at which

01484.0005 2092426.1

Page 175

Page 176 of 179

the ordinance is adopted and again after the meeting at which it is adopted.
* * * * * * * * * * * * * * * *
The foregoing ordinance was introduced at a regular meeting of the City Council of the City of
Sanger held on February 19, 2026, and was passed and adopted at a regular meeting of the City
Council held on _______________, 2026, by the following vote:
AYES:

COUNCILMEMBERS:

NOES:

COUNCILMEMBERS:

ABSENT:

COUNCILMEMBERS:

ABSTAIN:

COUNCILMEMBERS:

ATTEST:

APPROVED:

___________________________
Lina Martinez, City Clerk
City of Sanger

___________________________
Frank Gonzales, Mayor
City of Sanger

01484.0005 2092426.1

Page 176

Page 177 of 179

Exhibit A
Zoning Ordinance Map Amendment No. 2026-01 –
(Pre-Zoning)

01484.0005 2092426.1

Page 177

Page 178 of 179

R-1-6
R-1-6

R-1-6
R-1-6

LILY AVE

GLORIA AVE
R-1-6

RM-2.5

R-1-6

R-1-6

MOIR AVE
LILY AVE

R-1-6

DALTON AVE

CHERRY AVE

R-1-6

RM-2.5

R-1-6

WALTON AVE
R-1-6

R-1-6

Path: F:\2024\24-299\GIS\24-299\24-299.aprx

INDIANOLA AVE

NORTH AVE

O

Existing Zoning
R-1-6

Area of Interest
City Limits

RM-2.5

0

200
Feet

Sphere of Influence

Existing Zoning Map
City of Sanger

400

Page 178

RM-2.5

Page 179 of 179

R-1-6
R-1-6

R-1-6
R-1-6

LILY AVE

GLORIA AVE
R-1-6

RM-2.5

R-1-6

R-1-6

MOIR AVE
LILY AVE

R-1-6

DALTON AVE

CHERRY AVE

R-1-6

RM-2.5

R-1-6

WALTON AVE
R-1-6

R-1-6

NORTH AVE

Path: F:\2024\24-299\GIS\24-299\24-299.aprx

INDIANOLA AVE

RSC
11.42
Acres

O

Existing Zoning

Proposed Zoning

R-1-6

RSC

RM-2.5

0

200
Feet

Area of Interest
City Limits
Sphere of Influence

Proposed Zoning Map
City of Sanger

400

Page 179

RM-2.5

Outcome

Not yet recorded. The record stays open — outcomes are added as minutes and vote results are published.

Provenance

Where this record came from. Every source is listed, permanently.

  • Agenda Watch · Jul 20, 2026

Permanent ID DKT-2026-000135 — this record is never deleted.

Record history

Every change to this record, logged as it happened.

  • Jul 20, 2026 Filed on the Docket
  • Jul 20, 2026 Full document archived — public record

← The full Docket · every meeting, vote, and action on the permanent record · also in the National Record Index.